Accelerometry and Heart Rate as a Measure of Physical Fitness: Cross-Validation
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
PURPOSE: We recently reported on a new method to assess physical fitness, based on the combined use of accelerometry and heart rate (HR) registration. This study tested the validity of the prediction formula in a group of healthy young adults. METHODS: Twenty-six healthy subjects performed a maximal incremental test on a bicycle ergometer to determine VO2max. A triaxial accelerometer and a HR monitor were worn for 7 d under free-living conditions. The prediction formula developed in a previous experimental group (EXP) was applied on the cross-validation group (CV). RESULTS: No difference was found in subjects' characteristics between the EXP and CV groups except for accelerometer output (activity counts). Although measured VO2max could be predicted for 80% (P < 0.0001), a paired t-test showed a significant difference between measured and predicted VO2max (178 mL.min(-1); P = 0.015). Because of the difference in activity between the EXP and the CV groups, all data were combined and sorted according to activity counts, then two new groups were formed. As a result, EXP and CV groups were created that did not significantly differ in activity or any other parameters. The formula developed in the new experimental group (R2 = 0.74; P < 0.0001) explained 72% (P < 0.0001) of the variation in VO2max in the cross-validation group, a paired t-test showed no difference between measured and predicted VO2max, and Bland-Altman plotting showed no systematic bias. CONCLUSION: Although a good correlation was seen between measured and predicted VO2max in the cross-validation group, care should be taken in applying the prediction formula on groups that differ in physical activity from the current study population.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Åstrand, P. O., & Ryhming, I. (1954) · Journal of Applied Physiology · doi:10.1152/jappl.1954.7.2.218 · Cited by 1,558
Physical fitness and activity as separate heart disease risk factors: a meta-analysis
WILLIAMS, P. T. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200105000-00012 · Cited by 724 · cited 1×
“M aximal oxygen uptake (V̇O2max), the most widely used measure of physical fitness, is inversely related with several health outcomes, such as cardiovascular disease and coronary artery disease (25).”
Weyand, P. G., Kelly, M., Blackadar, T., Darley, J. C., Oliver, S. R., Ohlenbusch, N. E., Joffe, S. W., & Hoyt, R. W. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.1.451 · Cited by 61
Accelerometry and Heart Rate as a Measure of Physical Fitness: Proof of Concept
PLASQUI, G., & WESTERTERP, K. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000161805.61893.c0 · Cited by 56
Self-citation
Cited by
Assessment of physical activity: a critical appraisal
Westerterp, K. R. (2009) · European Journal of Applied Physiology · doi:10.1007/s00421-009-1000-2 · Cited by 459
Self-citationAssessing Physical Activity Using Wearable Monitors: Measures of Physical Activity
BUTTE, N. F., EKELUND, U., & WESTERTERP, K. R. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399c0e · Cited by 359
Self-citationWesterterp, K. R. (2013) · Frontiers in Physiology · doi:10.3389/fphys.2013.00090 · Cited by 321
Self-citationPredicting V˙O2max with an Objectively Measured Physical Activity in Japanese Women
CAO, Z.-B., MIYATAKE, N., HIGUCHI, M., MIYACHI, M., ISHIKAWA-TAKATA, K., & TABATA, I. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181af238d · Cited by 76
Cardiorespiratory fitness estimation in free-living using wearable sensors
Altini, M., Casale, P., Penders, J., & Amft, O. (2016) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2016.02.002 · Cited by 34
Metadata
- Authors
- PLASQUI, G., & WESTERTERP, K. R.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2006-08
- Volume
- 38
- Issue
- 8
- Pages
- 1510-1514
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2084448175
- Cited by
- 43
- References
- 5
- FWCI
- 1.76
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accelerometry and Heart Rate as a Measure of Physical Fitness: Cross-Validation. https://app.cochat.ai/papers/10.1249/01.mss.0000228942.55152.84
- The paper
- PLASQUI, G., & WESTERTERP, K. R. (2006). Accelerometry and Heart Rate as a Measure of Physical Fitness: Cross-Validation. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/01.mss.0000228942.55152.84
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.