Ability of Thigh-Worn ActiGraph and activPAL Monitors to Classify Posture and Motion
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
PURPOSE: This study compared sitting, standing, and stepping classifications from thigh-worn ActiGraph and activPAL monitors under laboratory and free-living conditions. METHODS: Adults wore both monitors on the right thigh while performing activities (six sitting, two standing, nine stepping, and one cycling) and writing on a whiteboard with intermittent stepping under laboratory conditions (n = 21) and under free-living conditions for 3 d (n = 18). Percent time correctly classified was calculated under laboratory conditions. Between-monitor agreement and weighted κ were calculated under free-living conditions. RESULTS: In the laboratory, both monitors correctly classified 100% of standing time and >95% of the time spent in four of six sitting postures. Both monitors demonstrated misclassification of laboratory stool sitting time (ActiGraph 14% vs. activPAL 95%). ActivPAL misclassified 14% of the time spent sitting with legs outstretched; ActiGraph was 100% accurate. Monitors were >95% accurate for stepping, although ActiGraph was less so for descending stairs (86%), ascending stairs (92%), and running at 2.91 m·s(-1) (93%). Monitors classified whiteboard writing differently (ActiGraph 83% standing/15% stepping vs. activPAL 98% standing/2% stepping). ActivPAL classified 93% of cycling time as stepping, whereas ActiGraph classified <1% of cycling time as stepping. During free-living wear, monitors had substantial agreement (86% observed; weighted κ = 0.77). Monitors classified similar amounts of time as sitting (ActiGraph 64% vs. activPAL 62%). There were differences in time recorded as standing (ActiGraph 21% vs. activPAL 27%) and stepping (ActiGraph 15% vs. activPAL 11%). CONCLUSIONS: Differences in data processing algorithms may have resulted in the observed disagreement in posture and activity classification between thigh-worn ActiGraph and activPAL. Despite between-monitor agreement in classifying sitting time under free-living conditions, ActiGraph appears to be more sensitive to free-living upright walking motions than activPAL.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Conducting accelerometer-based activity assessments in field-based research
TROST, S. G., MCIVER, K. L., & PATE, R. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185657.86065.98 · Cited by 2,033
Validation of Accelerometer Wear and Nonwear Time Classification Algorithm
CHOI, L., LIU, Z., MATTHEWS, C. E., & BUCHOWSKI, M. S. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181ed61a3 · Cited by 1,804
Hamilton, M. T., Hamilton, D. G., & Zderic, T. W. (2007) · Diabetes · doi:10.2337/db07-0882 · Cited by 1,655
Comparison of Accelerometer Cut Points for Predicting Activity Intensity in Youth
TROST, S. G., LOPRINZI, P. D., MOORE, R., & PFEIFFER, K. A. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318206476e · Cited by 1,360
Objectively Measured Sedentary Time, Physical Activity, and Metabolic Risk
Healy, G. N., Wijndaele, K., Dunstan, D. W., Shaw, J. E., Salmon, J., Zimmet, P. Z., & Owen, N. (2008) · Diabetes Care · doi:10.2337/dc07-1795 · Cited by 1,100
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Self-citationInterindividual variation in posture allocation: possible role in human obesity
Levine, J. A., Lanningham-Foster, L. M., McCrady, S. K., Krizan, A. C., Olson, L. R., Kane, P. H., Jensen, M. D., & Clark, M. M. (2005) · Science · doi:10.1126/science.1106561 · Cited by 705 · cited 1×
“Despite the inherent challenges and limitations of measuring sedentary behavior, there has been an increase in research focused on understanding the independent health effects of sedentary and light-intensity physical activities involving static muscle actions (6,15,17,21,25).”
BackgroundPhysical Activity for Health: What Kind? How Much? How Intense? On Top of What?
Powell, K. E., Paluch, A. E., & Blair, S. N. (2011) · Annual Review of Public Health · doi:10.1146/annurev-publhealth-031210-101151 · Cited by 685 · cited 1×
“physical activity and health outcomes (26).”
Amount of time spent in sedentary behaviors and cause-specific mortality in US adults
Matthews, C. E., George, S. M., Moore, S. C., Bowles, H. R., Blair, A., Park, Y., Troiano, R. P., Hollenbeck, A., & Schatzkin, A. (2012) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.111.019620 · Cited by 655 · cited 1×
“, G100 vertical axis counts per minute for ActiGraph) (17,22).”
BackgroundSelf-citationAssessing Physical Activity Using Wearable Monitors: Measures of Physical Activity
BUTTE, N. F., EKELUND, U., & WESTERTERP, K. R. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399c0e · Cited by 359 · cited 3×
“This study was strengthened by the presence of both controlled laboratory and free-living protocols (4).”
Background
Cited by
Validity of the ActivPAL monitor to distinguish postures: A systematic review
O’Brien, M. W., Wu, Y., Petterson, J. L., Bray, N. W., & Kimmerly, D. S. (2022) · Gait & Posture · doi:10.1016/j.gaitpost.2022.03.002 · Cited by 81
Massé, F., Gonzenbach, R. R., Arami, A., Paraschiv-Ionescu, A., Luft, A. R., & Aminian, K. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0060-2 · Cited by 77
“For instance, an accelerometer placed on thigh cannot distinguish accurately sitting from lying [15, 16].”
BackgroundUsing Bluetooth proximity sensing to determine where office workers spend time at work
Clark, B. K., Winkler, E. A., Brakenridge, C. L., Trost, S. G., & Healy, G. N. (2018) · PLOS ONE · doi:10.1371/journal.pone.0193971 · Cited by 40
Maylor, B. D., Edwardson, C. L., Dempsey, P. C., Patterson, M. R., Plekhanova, T., Yates, T., & Rowlands, A. V. (2022) · Sensors · doi:10.3390/s22249984 · Cited by 30
Accuracy of Consumer Monitors for Estimating Energy Expenditure and Activity Type
WOODMAN, J. A., CROUTER, S. E., BASSETT, D. R., FITZHUGH, E. C., & BOYER, W. R. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001090 · Cited by 29
Metadata
- Authors
- STEEVES, J. A., BOWLES, H. R., MCCLAIN, J. J., DODD, K. W., BRYCHTA, R. J., WANG, J., & CHEN, K. Y.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2015-05
- Volume
- 47
- Issue
- 5
- Pages
- 952-959
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2315738348
- Cited by
- 130
- References
- 10
- FWCI
- 6.53
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ability of Thigh-Worn ActiGraph and activPAL Monitors to Classify Posture and Motion. https://app.cochat.ai/papers/10.1249/mss.0000000000000497
- The paper
- STEEVES, J. A., BOWLES, H. R., MCCLAIN, J. J., DODD, K. W., BRYCHTA, R. J., WANG, J., & CHEN, K. Y. (2015). Ability of Thigh-Worn ActiGraph and activPAL Monitors to Classify Posture and Motion. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/mss.0000000000000497
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.