CoChat

Comparison of Sedentary Estimates between activPAL and Hip- and Wrist-Worn ActiGraph

Open access
KOSTER, ANNEMARIE, SHIROMA, ERIC J., CASEROTTI, PAOLO, MATTHEWS, CHARLES E., CHEN, KONG Y., GLYNN, NANCY W., HARRIS, TAMARA B. · 2016 · Medicine & Science in Sports & Exercise
Cited by 158

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Abstract

PURPOSE: Sedentary behavior is an emerging independent health risk factor. The accuracy of measuring sedentary time using accelerometers may depend on the wear location. This study in older adults evaluated the accuracy of various hip- and wrist-worn ActiGraph accelerometer cutoff points to define sedentary time using the activPAL as the reference method. METHODS: Data from 62 adults (mean age, 78.4 yr) of the Aging Research Evaluating Accelerometry study were used. Participants simultaneously wore an activPAL accelerometer on the thigh and ActiGraph accelerometers on the hip, dominant, and nondominant wrist for 7 d in a free-living environment. Using the activPAL as the reference criteria, we compared classification of sedentary time to hip-worn and wrist-worn ActiGraph accelerometers over a range of cutoff points for both 60-s and 15-s epochs. RESULTS: The optimal cutoff point for the hip vertical axis was <22 counts per minute with an area under the curve (AUC) of 0.85; the optimal hip vector magnitude cutoff point was <174 counts per minute with an AUC of 0.89. For the dominant wrist, the optimal vector magnitude cutoff point to define sedentary time was <2303 counts per minute (AUC, 0.86) and for the nondominant wrist <1853 counts per minute (AUC, 0.86). The optimal 15-s cutoff points resulted in lower agreements compared with activPAL. CONCLUSIONS: Hip- and wrist-worn ActiGraph data may be used to define sedentary time with a moderate to high accuracy when compared with activPAL. The observed optimal cutoff point for hip vertical axis <22 counts per minute is substantially lower than the standard <100 counts per minute. It is unknown how these optimal cutoff points perform in different populations. Results on an individual basis should therefore be interpreted with caution.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/mss.0000000000000924

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Cited by

See all 158

Metadata

Authors
KOSTER, A., SHIROMA, E. J., CASEROTTI, P., MATTHEWS, C. E., CHEN, K. Y., GLYNN, N. W., & HARRIS, T. B.
Venue
Medicine & Science in Sports & Exercise
Published
2016-08
Volume
48
Issue
8
Pages
1514-1522
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2319548482
Cited by
158
References
25
FWCI
10.04
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Sedentary Estimates between activPAL and Hip- and Wrist-Worn ActiGraph. https://app.cochat.ai/papers/10.1249/mss.0000000000000924
The paper
KOSTER, A., SHIROMA, E. J., CASEROTTI, P., MATTHEWS, C. E., CHEN, K. Y., GLYNN, N. W., & HARRIS, T. B. (2016). Comparison of Sedentary Estimates between activPAL and Hip- and Wrist-Worn ActiGraph. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/mss.0000000000000924

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.