Comparison of Sedentary Estimates between activPAL and Hip- and Wrist-Worn ActiGraph
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
PURPOSE: Sedentary behavior is an emerging independent health risk factor. The accuracy of measuring sedentary time using accelerometers may depend on the wear location. This study in older adults evaluated the accuracy of various hip- and wrist-worn ActiGraph accelerometer cutoff points to define sedentary time using the activPAL as the reference method. METHODS: Data from 62 adults (mean age, 78.4 yr) of the Aging Research Evaluating Accelerometry study were used. Participants simultaneously wore an activPAL accelerometer on the thigh and ActiGraph accelerometers on the hip, dominant, and nondominant wrist for 7 d in a free-living environment. Using the activPAL as the reference criteria, we compared classification of sedentary time to hip-worn and wrist-worn ActiGraph accelerometers over a range of cutoff points for both 60-s and 15-s epochs. RESULTS: The optimal cutoff point for the hip vertical axis was <22 counts per minute with an area under the curve (AUC) of 0.85; the optimal hip vector magnitude cutoff point was <174 counts per minute with an AUC of 0.89. For the dominant wrist, the optimal vector magnitude cutoff point to define sedentary time was <2303 counts per minute (AUC, 0.86) and for the nondominant wrist <1853 counts per minute (AUC, 0.86). The optimal 15-s cutoff points resulted in lower agreements compared with activPAL. CONCLUSIONS: Hip- and wrist-worn ActiGraph data may be used to define sedentary time with a moderate to high accuracy when compared with activPAL. The observed optimal cutoff point for hip vertical axis <22 counts per minute is substantially lower than the standard <100 counts per minute. It is unknown how these optimal cutoff points perform in different populations. Results on an individual basis should therefore be interpreted with caution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148 · cited 1×
“75 indicate ‘‘excellent’’ agreement (13).”
‘Small Changes' to Diet and Physical Activity Behaviors for Weight Management
Hills, A. P., Byrne, N. M., Lindstrom, R., & Hill, J. O. (2013) · Obesity Facts · doi:10.1159/000345030 · Cited by 9,493
Physical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638 · cited 1×
“Previous studies have used them to characterize sedentary behavior, light-intensity physical activity, and moderate-to-vigorous intensity physical activity in a wide range of populations (2,7,14,18,20,23).”
BackgroundCalibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
Amount of Time Spent in Sedentary Behaviors in the United States, 2003-2004
Matthews, C. E., Chen, K. Y., Freedson, P. S., Buchowski, M. S., Beech, B. M., Pate, R. R., & Troiano, R. P. (2008) · American Journal of Epidemiology · doi:10.1093/aje/kwm390 · Cited by 2,631 · cited 6×
“For each optimal cutoff point as well as the accepted standard cutoff points (hip vertical G100 counts per minute and hip VM G200 counts per minute) (1,15,23), we also calculated the mean difference in daily sedentary wear time (minId) between the ActiGraph and the activPAL.”
BackgroundMethodInfluentialSelf-citationLetter to the Editor: Standardized use of the terms “sedentary” and “sedentary behaviours”
Networ, S. B. R. (2012) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h2012-024 · Cited by 1,873
Validation of Accelerometer Wear and Nonwear Time Classification Algorithm
CHOI, L., LIU, Z., MATTHEWS, C. E., & BUCHOWSKI, M. S. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181ed61a3 · Cited by 1,804 · cited 2×
“Hip and wrist accelerometer data, using all three axes, were screened for periods of wear (‘‘wear time’’) using methods described by Choi et al (3).”
MethodSelf-citationPerkins, N. J., & Schisterman, E. F. (2006) · American Journal of Epidemiology · doi:10.1093/aje/kwj063 · Cited by 1,759 · cited 1×
“The optimal cutoff point was defined as the threshold that maximized the sum of the sensitivity and specificity (9,16).”
BackgroundValidation and comparison of ActiGraph activity monitors
Sasaki, J. E., John, D., & Freedson, P. S. (2011) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2011.04.003 · Cited by 1,317 · cited 1×
“Previous studies have used them to characterize sedentary behavior, light-intensity physical activity, and moderate-to-vigorous intensity physical activity in a wide range of populations (2,7,14,18,20,23).”
BackgroundEvolution of accelerometer methods for physical activity research
Troiano, R. P., McClain, J. J., Brychta, R. J., & Chen, K. Y. (2014) · British Journal of Sports Medicine · doi:10.1136/bjsports-2014-093546 · Cited by 968
Self-citationValidation of Wearable Monitors for Assessing Sedentary Behavior
KOZEY-KEADLE, S., LIBERTINE, A., LYDEN, K., STAUDENMAYER, J., & FREEDSON, P. S. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31820ce174 · Cited by 905 · cited 4×
“Compared with direct observation both in a laboratory setting (8) and in free-living individuals (12), the activPAL has shown to be an accurate and precise monitor for measuring sedentary time.”
BackgroundMethodInfluentialSedentary behavior and health outcomes among older adults: a systematic review
Rezende, L. F. M. D., Rey-López, J. P., Matsudo, V. K. R., & Luiz, O. D. C. (2014) · BMC Public Health · doi:10.1186/1471-2458-14-333 · Cited by 685 · cited 1×
“T here is a growing interest in sedentary behavior as an independent risk factor for health (5,6).”
BackgroundGrant, P. M., Ryan, C. G., Tigbe, W. W., & Granat, M. H. (2006) · British Journal of Sports Medicine · doi:10.1136/bjsm.2006.030262 · Cited by 681 · cited 3×
“Compared with direct observation both in a laboratory setting (8) and in free-living individuals (12), the activPAL has shown to be an accurate and precise monitor for measuring sedentary time.”
BackgroundMethodCalibration of Accelerometer Output for Adults
MATTHEW, C. E. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185659.11982.3d · Cited by 659
Too much sitting – A health hazard
Dunstan, D. W., Howard, B., Healy, G. N., & Owen, N. (2012) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2012.05.020 · Cited by 574 · cited 1×
“T here is a growing interest in sedentary behavior as an independent risk factor for health (5,6).”
BackgroundTudor-Locke, C., Camhi, S., & Troiano, R. (2012) · Preventing Chronic Disease · doi:10.5888/pcd9.110332 · Cited by 317 · cited 4×
“For each optimal cutoff point as well as the accepted standard cutoff points (hip vertical G100 counts per minute and hip VM G200 counts per minute) (1,15,23), we also calculated the mean difference in daily sedentary wear time (minId) between the ActiGraph and the activPAL.”
BackgroundMethodInfluentialAguilar-Farías, N., Brown, W. J., & Peeters, G. M. E. E. (. (2014) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2013.07.002 · Cited by 306
Utilization and Harmonization of Adult Accelerometry Data: Review and Expert Consensus
WIJNDAELE, K., WESTGATE, K., STEPHENS, S. K., BLAIR, S. N., BULL, F. C., CHASTIN, S. F. M., DUNSTAN, D. W., EKELUND, U., ESLIGER, D. W., FREEDSON, P. S., et al. (2015) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000661 · Cited by 297 · cited 1×
“There are several large ongoing studies in older adults that included accelerometry (24) so methodical research”
BackgroundSelf-citationCalibration and Validation of Wearable Monitors
BASSETT, D. R., ROWLANDS, A., & TROST, S. G. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399cf7 · Cited by 292
Machine learning for activity recognition: hip versus wrist data
Trost, S. G., Zheng, Y., & Wong, W.-K. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/11/2183 · Cited by 181 · cited 1×
“data in children and adolescent shows high recognition rates for sitting time in laboratory-based study (22).”
BackgroundREGRET GRAPHS, DIAGNOSTIC UNCERTAINTY AND YOUDEN'S INDEX
HILDEN, J., & GLASZIOU, P. (1996) · Statistics in Medicine · doi:10.1002/(sici)1097-0258(19960530)15:10<969::aid-sim211>3.0.co;2-9 · Cited by 181 · cited 1×
“The optimal cutoff point was defined as the threshold that maximized the sum of the sensitivity and specificity (9,16).”
BackgroundEstimating Physical Activity in Youth Using a Wrist Accelerometer
CROUTER, S. E., FLYNN, J. I., & BASSETT, D. R. (2015) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000502 · Cited by 144 · cited 1×
“to estimate sedentary behavior from ActiGraph wrist accelerometer data (4,10,11).”
BackgroundAssessing Sedentary Behavior with the GENEActiv: Introducing the Sedentary Sphere
ROWLANDS, A. V., OLDS, T. S., HILLSDON, M., PULSFORD, R., HURST, T. L., ESTON, R. G., GOMERSALL, S. R., JOHNSTON, K., & LANGFORD, J. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000224 · Cited by 117 · cited 1×
“Another recent study shows that the wristworn GENEActiv, using a different methodology, the Sedentary Sphere concept, was able to determine posture with a more than 80% agreement compared to activPAL (17).”
Examination of Different Accelerometer Cut-Points for Assessing Sedentary Behaviors in Children
Kim, Y., Lee, J. M., Peters, B. P., Gaesser, G. A., & Welk, G. J. (2014) · PLoS ONE · doi:10.1371/journal.pone.0090630 · Cited by 82 · cited 1×
“to estimate sedentary behavior from ActiGraph wrist accelerometer data (4,10,11).”
Calibration and cross‐validation of a wrist‐worn Actigraph in young preschoolers
Johansson, E., Ekelund, U., Nero, H., Marcus, C., & Hagströmer, M. (2015) · Pediatric Obesity · doi:10.1111/j.2047-6310.2013.00213.x · Cited by 57 · cited 1×
“to estimate sedentary behavior from ActiGraph wrist accelerometer data (4,10,11).”
Cited by
Jefferis, B. J., Parsons, T. J., Sartini, C., Ash, S., Lennon, L. T., Papacosta, O., Morris, R. W., Wannamethee, S. G., Lee, I.-M., & Whincup, P. H. (2019) · British Journal of Sports Medicine · doi:10.1136/bjsports-2017-098733 · Cited by 244
Loyen, A., Clarke-Cornwell, A. M., Anderssen, S. A., Hagströmer, M., Sardinha, L. B., Sundquist, K., Ekelund, U., Steene-Johannessen, J., Baptista, F., Hansen, B. H., et al. (2017) · Sports Medicine · doi:10.1007/s40279-016-0658-y · Cited by 182
“It should be noted, however, that the relative intensity of activities is different for older adults, with research showing cut-points around \22 counts/min for sedentary behaviour [39] and C1040 counts/min for MVPA [40].”
BackgroundJefferis, B. J., Parsons, T. J., Sartini, C., Ash, S., Lennon, L. T., Papacosta, O., Morris, R. W., Wannamethee, S. G., Lee, I.-M., & Whincup, P. H. (2019) · International Journal of Cardiology · doi:10.1016/j.ijcard.2018.12.024 · Cited by 65
Dohrn, I.-M., Welmer, A.-K., & Hagströmer, M. (2019) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-019-0878-2 · Cited by 57
“In addition, the ActiGraph records body movement and not postures, and consequently our sedentary time measure may include standing time [34].”
BackgroundPrince, S. A., Reed, J. L., Cotie, L. M., Harris, J., Pipe, A. L., & Reid, R. D. (2018) · International Journal of Cardiology · doi:10.1016/j.ijcard.2018.07.082 · Cited by 40
Metadata
- Authors
- KOSTER, A., SHIROMA, E. J., CASEROTTI, P., MATTHEWS, C. E., CHEN, K. Y., GLYNN, N. W., & HARRIS, T. B.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2016-08
- Volume
- 48
- Issue
- 8
- Pages
- 1514-1522
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2319548482
- Cited by
- 158
- References
- 25
- FWCI
- 10.04
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.