CoChat

Moving Forward with Backward Compatibility: Translating Wrist Accelerometer Data

Open access
ROWLANDS, ALEX V., CLIFF, DYLAN P., FAIRCLOUGH, STUART J., BODDY, LYNNE M., OLDS, TIM S., PARFITT, GAYNOR, NOONAN, ROB J., DOWNS, SAMANTHA J., KNOWLES, ZOE R., BEETS, MICHAEL W. · 2016 · Medicine & Science in Sports & Exercise
Cited by 36

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

PURPOSE: This study aimed to provide a means for calibrating raw acceleration data from wrist-worn accelerometers in relation to past estimates of children's moderate-to-vigorous physical activity (MVPA) from a range of cut points applied to hip-worn ActiGraph data. METHODS: This is a secondary analysis of three studies with concurrent 7-d accelerometer wear at the wrist (GENEActiv) and hip (ActiGraph) in 238 children age 9-12 yr. The time spent above acceleration (ENMO) thresholds of 100, 150, 200, 250, 300, 350, and 400 mg from wrist acceleration data (≤5-s epoch) was calculated for comparison with MVPA estimated from widely used children's hip-worn ActiGraph MVPA cut points (Freedson/Trost, 1100 counts per minute; Pate, 1680 counts per minute; Evenson, 2296 counts per minute; Puyau, 3200 counts per minute) with epochs of ≤5, 15, and 60 s. RESULTS: The optimal ENMO thresholds for alignment with MVPA estimates from ActiGraph cut points determined from 70% of the sample and cross validated with the remaining 30% were as follows: Freedson/Trost = ENMO 150+ mg, irrespective of ActiGraph epoch (intraclass correlation [ICC] ≥ 0.65); Pate = ENMO 200+ mg, irrespective of ActiGraph epoch (ICC ≥ 0.67); Evenson = ENMO 250+ mg for ≤5- and 15-s epochs (ICC ≥ 0.69) and ENMO 300+ mg for 60-s epochs (ICC = 0.73); Puyau = ENMO 300+ mg for ≤5-s epochs (ICC = 0.73), ENMO 350+ mg for 15-s epochs (ICC = 0.73), and ENMO 400+ mg for 60-s epochs (ICC = 0.65). Agreement was robust with cross-validation ICC = 0.62-0.71 and means within ∣7.8∣% ± 4.9% of MVPA estimates from ActiGraph cut points, except Puyau 60-s epochs (ICC = 0.42). CONCLUSION: Incremental ENMO thresholds enable children's acceleration data measured at the wrist to be simply and directly compared, at a group level, with past estimates of MVPA from hip-worn ActiGraphs across a range of cut points.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/mss.0000000000001015

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 36

Metadata

Authors
ROWLANDS, A. V., CLIFF, D. P., FAIRCLOUGH, S. J., BODDY, L. M., OLDS, T. S., PARFITT, G., NOONAN, R. J., DOWNS, S. J., KNOWLES, Z. R., & BEETS, M. W.
Venue
Medicine & Science in Sports & Exercise
Published
2016-11
Volume
48
Issue
11
Pages
2142-2149
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2463984801
Cited by
36
References
8
FWCI
4.79
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Moving Forward with Backward Compatibility: Translating Wrist Accelerometer Data. https://app.cochat.ai/papers/10.1249/mss.0000000000001015
The paper
ROWLANDS, A. V., CLIFF, D. P., FAIRCLOUGH, S. J., BODDY, L. M., OLDS, T. S., PARFITT, G., NOONAN, R. J., DOWNS, S. J., KNOWLES, Z. R., & BEETS, M. W. (2016). Moving Forward with Backward Compatibility: Translating Wrist Accelerometer Data. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/mss.0000000000001015

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.