Objective Assessment of Activity in Older Adults at Risk for Mobility Disability
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Purpose: The purpose of this study was to evaluate the validity of three objective measures of physical activity (Accusplit Eagle 120 mechanical pedometer (AE120), NL-2000 electronic pedometer, and IDEEA pattern-recognition device) that varied in their levels of sophistication, among older adults at risk for mobility disability. In addition, we examined the potential influences of gait speed and body mass index (BMI) on step count accuracy. Methods: Step counts recorded on the three devices were compared against manual step counts made by two investigators as each participant walked 131 m around an indoor track at their preferred walking speed (N = 29; 75.8 ± 4.2 yr). Gait speed was determined by dividing total distance walked by time to completion. BMI was calculated from height and body mass measurements. Results: All three devices significantly underestimated steps taken (AE120 = 22.8 ± 53.9 steps; NL-2000 = 4.0 ± 5.8 steps; IDEEA = 5.6 ± 7.8 steps), but there was no significant difference between devices (P = 0.084). Steps counted by the AE120, NL-2000, and IDEEA were significantly correlated with manual step counts (r = 0.508, 0.980, and 0.965, respectively; P ≤ 0.005). However, the AE120 was not clinically acceptable, sharing only 26% common variance with actual steps taken. The accuracy of the three devices was not influenced systematically by either gait speed or BMI. Conclusion: Our data show that the AE120 is a poor choice for measuring physical activity in older adults at risk for mobility disability. Both the NL-2000 and IDEEA devices have acceptable measurement qualities; however, the NL-2000 is the more practical of the two for use in either research or clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Meaningful change and responsiveness in common physical performance measures in older adults.
Perera, S., Mody, S. H., Woodman, R. C., & Studenski, S. A. (2006) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2006.00701.x · Cited by 2,513
Physical performance measures in the clinical setting
Studenski, S., Perera, S., Wallace, D., Chandler, J. M., Duncan, P. W., Rooney, E., Fox, M., & Guralnik, J. M. (2003) · Journal of the American Geriatrics Society · doi:10.1046/j.1532-5415.2003.51104.x · Cited by 1,218
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Validity of 10 Electronic Pedometers for Measuring Steps, Distance, and Energy Cost
CROUTER, S. E., SCHNEIDER, P. L., KARABULUT, M., & BASSETT, D. R. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000078932.61440.a2 · Cited by 899
Utility of Pedometers for Assessing Physical Activity: Convergent Validity
Tudor-Locke, C., Williams, J. E., Reis, J. P., & Pluto, D. (2002) · Sports Medicine · doi:10.2165/00007256-200232120-00004 · Cited by 649
Accuracy of five electronic pedometers for measuring distance walked
BASSETT, D. R., AINSWORTH, B. E., LEGGETT, S. R., MATHIEN, C. A., MAIN, J. A., HUNTER, D. C., & DUNCAN, G. E. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199608000-00019 · Cited by 552
Comparison of Pedometer and Accelerometer Accuracy under Controlled Conditions
LE MASURIER, G. C., & TUDOR-LOCKE, C. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000064996.63632.10 · Cited by 360
Spring-Levered versus Piezo-Electric Pedometer Accuracy in Overweight and Obese Adults
CROUTER, S. E., SCHNEIDER, P. L., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000181677.36658.a8 · Cited by 295
Foster, R. C., Lanningham-Foster, L. M., Manohar, C., McCrady, S. K., Nysse, L. J., Kaufman, K. R., Padgett, D. J., & Levine, J. A. (2005) · Preventive Medicine · doi:10.1016/j.ypmed.2005.07.006 · Cited by 187
Comparison of two waist-mounted and two ankle-mounted electronic pedometers
Karabulut, M., Crouter, S. E., & Bassett, D. R. (2005) · European Journal of Applied Physiology · doi:10.1007/s00421-005-0018-3 · Cited by 139
Cited by
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
“The majority of articles compared activity monitor determined energy expenditure with DLW [73, 77, 80, 96, 105, 274, 275, 277, 278, 280, 281, 285, 292, 293, 295, 296, 300, 303–305, 311, 313, 317, 323], while activity monitor determined steps [119, 271, 283, 287, 289, 298, 299, 306, 307, 314, 315, 318], distance travel…”
Kowalski, K., Rhodes, R., Naylor, P.-J., Tuokko, H., & MacDonald, S. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-148 · Cited by 212
“99) for steps counted by direct observation and pedometry [56,63] and steps counted by direct observation and accelerometry [64].”
BackgroundMethodInfluentialPhysical activity levels in older adults with intellectual disabilities are extremely low
Hilgenkamp, T. I. M., Reis, D., van Wijck, R., & Evenhuis, H. M. (2012) · Research in Developmental Disabilities · doi:10.1016/j.ridd.2011.10.011 · Cited by 183
Rydwik, E., Frändin, K., & Akner, G. (2010) · Archives of Gerontology and Geriatrics · doi:10.1016/j.archger.2009.12.001 · Cited by 71
“Objective measurements such as accelerometer or pedometer were not chosen due to lack of evidence of validity and reliability for frail elderly people at the time of the study (Marsh et al., 2007).”
MethodCommunity Weight Loss to Combat Obesity and Disability in At-Risk Older Adults
Rejeski, W. J., Ambrosius, W. T., Burdette, J. H., Walkup, M. P., & Marsh, A. P. (2017) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/glw252 · Cited by 58
Self-citation
Metadata
- Authors
- MARSH, A. P., VANCE, R. M., FREDERICK, T. L., HESSELMANN, S. A., & REJESKI, W. J.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2007-06
- Volume
- 39
- Issue
- 6
- Pages
- 1020-1026
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W1965639995
- Cited by
- 57
- References
- 11
- FWCI
- 3.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.