Evaluation of the Omron HJ-720ITC Pedometer under Free-Living Conditions
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
INTRODUCTION: The primary purpose of this study was to examine the accuracy of the Omron HJ-720ITC piezoelectric pedometer in a free-living environment during a 24-h period. A secondary purpose was to compare the accuracy the Omron to that of a spring-levered pedometer. METHODS: A total of 62 adult volunteers were classified according to body mass index (BMI) category: normal weight (n = 19), overweight (n = 23), and obese (n = 20). Subjects wore five devices during a 24-h period except when bathing or sleeping. The criterion pedometer (StepWatch-3) was worn on the lateral side of the right ankle. Omron HJ-720ITC pedometers were worn in three locations: (a) on the belt, (b) in the pants pocket, and (c) on a lanyard around the neck. A comparison pedometer (Yamax SW-200) was worn on the belt. RESULTS: The Omron HJ-720ITC underestimated the steps per day in all three BMI categories compared with the criterion measure (P < 0.05). The Omron was most accurate in the pocket location, recording 68%, 70%, and 65% of steps in the normal, overweight, and obese BMI categories, respectively. In the obese group, the Omron was more accurate than the Yamax pedometer, but in the normal and overweight groups, it was less accurate than the Yamax. CONCLUSIONS: Results from our study show that the Omron significantly underestimates steps per day under free-living conditions. This is due, in part, to the presence of a 4-s step filter that contributes to an underestimation of steps accumulated during intermittent activities. In the pocket, the Omron accuracy was similar for lean, overweight, and obese individuals. In contrast, the accuracy of the Yamax pedometer declined with increasing BMI categories.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Validity of 10 Electronic Pedometers for Measuring Steps, Distance, and Energy Cost
CROUTER, S. E., SCHNEIDER, P. L., KARABULUT, M., & BASSETT, D. R. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000078932.61440.a2 · Cited by 899
Self-citationAccuracy of five electronic pedometers for measuring distance walked
BASSETT, D. R., AINSWORTH, B. E., LEGGETT, S. R., MATHIEN, C. A., MAIN, J. A., HUNTER, D. C., & DUNCAN, G. E. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199608000-00019 · Cited by 552
Self-citationHow humans walk: Bout duration, steps per bout, and rest duration
Orendurff, M. S. (2008) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2007.11.0197 · Cited by 306 · cited 2×
“The StepWatch-3 is considered to be a good criterion because of its high level of accuracy in step counting, regardless of BMI and walking speed (13,18).”
BackgroundSpring-Levered versus Piezo-Electric Pedometer Accuracy in Overweight and Obese Adults
CROUTER, S. E., SCHNEIDER, P. L., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000181677.36658.a8 · Cited by 295 · cited 14×
“Thus, the purpose of this study was twofold: 1) to examine the validity and reliability of the Omron HJ-720ITC piezoelectric pedometer in multiple wear locations (on the waist, in a pants pocket, or attached to a string around the neck) and 2) to compare it with two other pedometers (SW and Yamax SW-200) in a free-liv…”
BackgroundResultSelf-citationFoster, R. C., Lanningham-Foster, L. M., Manohar, C., McCrady, S. K., Nysse, L. J., Kaufman, K. R., Padgett, D. J., & Levine, J. A. (2005) · Preventive Medicine · doi:10.1016/j.ypmed.2005.07.006 · Cited by 187 · cited 1×
“, Seattle, WA) is a valid and accurate device for measuring steps in laboratory settings (4,9,13,21,22) and can be used as a criterion device to validate waist-mounted pedometers during a 24-h period (13).”
Comparison of two waist-mounted and two ankle-mounted electronic pedometers
Karabulut, M., Crouter, S. E., & Bassett, D. R. (2005) · European Journal of Applied Physiology · doi:10.1007/s00421-005-0018-3 · Cited by 139
Self-citationBioelectrical impedance underestimates total and truncal fatness in abdominally obese women
Neovius, M., Hemmingsson, E., Freyschuss, B., & Uddén, J. (2006) · Obesity · doi:10.1038/oby.2006.199 · Cited by 119 · cited 1×
“Body composition estimated by bioelectrical impedance analysis is less accurate in overweight and obese subjects compared with normalweight subjects (17); therefore, several measures of adiposity were used as verification to confirm that we had three groups of individuals (normal body mass index (BMI) 19–24.”
Method
Cited by
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Validity of Consumer-Based Physical Activity Monitors for Specific Activity Types
NELSON, M. B., KAMINSKY, L. A., DICKIN, D. C., & MONTOYE, A. H. K. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000933 · Cited by 205
“This finding was also exhibited by the OM (underestimating steps by 74%), which has been previously shown to underestimate steps in free-living settings (22).”
Morgan, P. J., Collins, C. E., Plotnikoff, R. C., Callister, R., Burrows, T., Fletcher, R., Okely, A. D., Young, M. D., Miller, A., Lloyd, A. B., et al. (2014) · Preventive Medicine · doi:10.1016/j.ypmed.2013.12.019 · Cited by 179
Lloyd, A. B., Lubans, D. R., Plotnikoff, R. C., Collins, C. E., & Morgan, P. J. (2014) · Appetite · doi:10.1016/j.appet.2014.04.010 · Cited by 177
Lee, J. A., Williams, S. M., Brown, D. D., & Laurson, K. R. (2015) · Journal of Sports Sciences · doi:10.1080/02640414.2014.981848 · Cited by 169
“…YX underestimates steps at slower speeds but becomes more accurate as speed increases (Crouter et al., 2003; Schneider et al., 2003, 2004), while the OP possesses high accuracy during treadmill walking at all speeds (Dondzila et al., 2012; Holbrook, Barreira, & Kang, 2009; Silcott et al., 2011).”
BackgroundResult
Metadata
- Authors
- SILCOTT, N. A., BASSETT, D. R., THOMPSON, D. L., FITZHUGH, E. C., & STEEVES, J. A.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2011-09
- Volume
- 43
- Issue
- 9
- Pages
- 1791-1797
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W1988471307
- Cited by
- 78
- References
- 8
- FWCI
- 5.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.