CoChat

Validity of Self-Reported Measures of Workplace Sitting Time and Breaks in Sitting Time

Open access
CLARK, BRONWYN K., THORP, ALICIA A., A.H. WINKLER, ELISABETH, GARDINER, PAUL A., HEALY, GENEVIEVE N., OWEN, NEVILLE, DUNSTAN, DAVID W. · 2011 · Medicine & Science in Sports & Exercise
Cited by 109

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

PURPOSE: To understand the prevalence and potential health effect of prolonged workplace sedentary (sitting) time, valid measures are required. Here, we examined the criterion validity of a brief self-reported measure of workplace sitting time and breaks in sitting time. METHODS: An interviewer-administered questionnaire was used to assess workplace sitting time (h·d(-1)) and breaks from sitting per hour at work in a convenience sample of 121 full-time workers (36% men, mean age = 37 yr, 53% office based). These self-reported measures were compared with accelerometer-derived sedentary time (hours per day, <100 counts per minute) and breaks per sedentary hour (number of times, ≥100 counts per minute) during work hours. RESULTS: Self-reported sitting time was significantly correlated with accelerometer-derived sedentary time (Pearson r = 0.39, 95% confidence interval = 0.22-0.53), with an average sitting time 0.45 h·d(-1) higher than average sedentary time. Bland-Altman plots and regression analysis showed positive associations between the difference in sitting and sedentary time and the average of sitting and sedentary time (mean difference = -2.75 h + 0.47 × average sitting and sedentary time; limits of agreement = ±2.25 h·d(-1)). The correlation of self-reported breaks per sitting hour with accelerometer-derived breaks per sedentary hour was also statistically significant (Spearman rs = 0.26, 95% confidence interval = 0.11-0.44). CONCLUSIONS: This study is the first to examine the criterion validity of an interviewer-administered questionnaire measure of workplace sitting time and breaks in sitting time using objective criterion measures. The workplace sitting measure has acceptable properties for use in observational studies concerned with sedentary behavior in groups of workers; however, the wide limits of agreement suggest caution in estimating individuals' sitting time with high precision. Using self-reported measures to capture patterns of workplace sitting (such as breaks in sitting time) requires further development.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/mss.0b013e31821820a2

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

Metadata

Authors
CLARK, B. K., THORP, A. A., A.H. WINKLER, E., GARDINER, P. A., HEALY, G. N., OWEN, N., & DUNSTAN, D. W.
Venue
Medicine & Science in Sports & Exercise
Published
2011-10
Volume
43
Issue
10
Pages
1907-1912
ISSN
0195-9131 (ISSN-L)
OpenAlex
W1982771070
Cited by
109
References
9
FWCI
5.39
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.