CoChat

Determination of Maximal Lactate Steady State in Healthy Adults: Can NIRS Help?

Open access
BELLOTTI, CECILIA, CALABRIA, ELISA, CAPELLI, CARLO, POGLIAGHI, SILVIA · 2013 · Medicine & Science in Sports & Exercise

The DOI matches its Crossref record; 40 of the 41 references it cites were found in a registry or an index.

Abstract

PURPOSE: We tested the hypothesis that the maximal lactate steady state (MLSS) can be accurately determined in healthy subjects based on measures of deoxygenated hemoglobin (deoxyHb), an index of oxygen extraction measured noninvasively by near-infrared spectroscopy (NIRS). METHODS: Thirty-two healthy men (mean ± SD age = 48 ± 17 yr, range = 23-74 yr) performed an incremental cycling test to exhaustion and square wave tests for MLSS determination. Cardiorespiratory variables were measured bbb and deoxyHb was monitored noninvasively on the right vastus lateralis with a quantitative NIRS device. The individual values of V˙O2 and HR corresponding to the MLSS were calculated and compared to the NIRS-derived MLSS (NIRSMLSS) that was, in turn, determined by double linear function fitting of deoxyHb during the incremental exercise. RESULTS: V˙O2 and HR at MLSS were 2.25 ± 0.54 L·min (76% ± 9% V˙O2max) and 133 ± 14 bpm (81% ± 7% HRmax), respectively. Muscle O2 extraction increased as a function of exercise intensity up to a deflection point, NIRSMLSS, at which V˙O2 and HR were 2.23 ± 0.59 L·min (76% ± 9% V˙O2max) and 136 ± 17 bpm (82% ± 8% HRmax), respectively. For both V˙O2 and HR, the difference of NIRSMLSS from MLSS values was not significant and the measures were highly correlated (r = 0.81 and r = 0.76). The Bland-Altman analysis confirmed a nonsignificant bias for V˙O2 and HR (-0.015 L·min and 3 bpm, respectively) and a small imprecision of 0.26 L·min and 8 bpm. CONCLUSIONS: A plateau in muscle O2 extraction was demonstrated in coincidence with MLSS during an incremental cycling exercise, confirming the hypothesis that this functional parameter can be accurately estimated with a quantitative NIRS device. The main advantages of NIRSMLSS over lactate-based techniques are the noninvasiveness and the time/cost efficiency.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/mss.0b013e3182828ab2

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 65

Metadata

Authors
BELLOTTI, C., CALABRIA, E., CAPELLI, C., & POGLIAGHI, S.
Affiliations
University of Verona (IT)
Venue
Medicine & Science in Sports & Exercise
Published
2013-06
Volume
45
Issue
6
Pages
1208-1216
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2316058784
Cited by
65
References
41
Citations by year
2026: 3 · 2025: 4 · 2024: 3 · 2023: 6 · 2022: 6 · 2021: 4 · 2020: 2 · 2019: 11 · 2018: 4 · 2017: 2 · 2016: 12 · 2015: 4 · 2014: 2 · 2013: 2
FWCI
15.76
Type
journal article
Language
en
Open access
Licence
other-oa
Locations
  • Medicine & Science in Sports & Exercise (publishedVersion)
  • PubMed (publishedVersion)
  • Archivio Istituzionale della Ricerca (Universita Degli Studi Di Milano) (submittedVersion, other-oa)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
  • Health Sciences › Medicine › Physiology (medical) › Exercise and Physiological Responses
Keywords
maximal lactate steady state, near-infrared spectroscopy, deoxyhemoglobin, muscle oxygen extraction, incremental cycling test, exercise intensity, oxygen consumption, heart rate, healthy adults
MeSH terms
Adult, Aged, Bicycling, Exercise Test, Hemoglobins, Humans, Male, Middle Aged, Anaerobic Threshold, Biomarkers, Exercise, Linear Models, Spectroscopy, Near-Infrared, Lactic Acid, Quadriceps Muscle, Healthy Volunteers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.