Determination of Maximal Lactate Steady State in Healthy Adults: Can NIRS Help?
Open accessThe DOI matches its Crossref record; 40 of the 41 references it cites were found in a registry or an index.
Abstract
PURPOSE: We tested the hypothesis that the maximal lactate steady state (MLSS) can be accurately determined in healthy subjects based on measures of deoxygenated hemoglobin (deoxyHb), an index of oxygen extraction measured noninvasively by near-infrared spectroscopy (NIRS). METHODS: Thirty-two healthy men (mean ± SD age = 48 ± 17 yr, range = 23-74 yr) performed an incremental cycling test to exhaustion and square wave tests for MLSS determination. Cardiorespiratory variables were measured bbb and deoxyHb was monitored noninvasively on the right vastus lateralis with a quantitative NIRS device. The individual values of V˙O2 and HR corresponding to the MLSS were calculated and compared to the NIRS-derived MLSS (NIRSMLSS) that was, in turn, determined by double linear function fitting of deoxyHb during the incremental exercise. RESULTS: V˙O2 and HR at MLSS were 2.25 ± 0.54 L·min (76% ± 9% V˙O2max) and 133 ± 14 bpm (81% ± 7% HRmax), respectively. Muscle O2 extraction increased as a function of exercise intensity up to a deflection point, NIRSMLSS, at which V˙O2 and HR were 2.23 ± 0.59 L·min (76% ± 9% V˙O2max) and 136 ± 17 bpm (82% ± 8% HRmax), respectively. For both V˙O2 and HR, the difference of NIRSMLSS from MLSS values was not significant and the measures were highly correlated (r = 0.81 and r = 0.76). The Bland-Altman analysis confirmed a nonsignificant bias for V˙O2 and HR (-0.015 L·min and 3 bpm, respectively) and a small imprecision of 0.26 L·min and 8 bpm. CONCLUSIONS: A plateau in muscle O2 extraction was demonstrated in coincidence with MLSS during an incremental cycling exercise, confirming the hypothesis that this functional parameter can be accurately estimated with a quantitative NIRS device. The main advantages of NIRSMLSS over lactate-based techniques are the noninvasiveness and the time/cost efficiency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“For instance, the [HHbMb] breakpoint during ramp exercise is suggested to resemble an upper limit of fractional oxygen extraction in the exercising leg muscles during incremental exercise [9–11] and approximates VT2 [10,12,11,13–15], maximal lactate steady state [14,16] and critical power [14].”
From Oxygenation Threshold Derived from Near-Infrared Spectroscopy: Reliability and Its Relationship with the First Ventilatory Threshold (2016) · cites this paper as [16]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“This plateau-like response has been associated with other physiological thresholds, especially those considered indicators of the maximal metabolic steady state, which delineate heavy and severe exercise domains (Bellotti et al. 2013; Keir et al. 2015, Turnes et al. 2019; Possamai et al. 2023).”
From Comparison of NIRS-derived [HHb] breakpoints and concordance with lactate thresholds during speed- and slope-based incremental running tests (2026) · cites this paper as Bellotti et al. 2013
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“During CW cycling exercise, SmO2 at the VL will rapidly deoxygenate before reaching a quasi-steady state within 60–120 s, similar to the primary onset phase of systemic V̇O2 kinetics (21, 22).”
From Comparing the reliability of muscle oxygen saturation with common performance and physiological markers across cycling exercise intensity (2023) · cites this paper as [22]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Multiple studies have validated various stationary NIRS sensors with each of the physiological and performance markers outlined above, during various modes of exercise (12, 17, 22, 29–31).”
From Comparing the reliability of muscle oxygen saturation with common performance and physiological markers across cycling exercise intensity (2023) · cites this paper as [22]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Plum, F. (1960) · Archives of Neurology · doi:10.1001/archneur.1960.03840090124020 · Cited by 10,364
(2014) · Medical Entomology and Zoology · Cited by 9,400
A new method for detecting anaerobic threshold by gas exchange
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.6.2020 · Cited by 4,103
Age-predicted maximal heart rate revisited
Tanaka, H., Monahan, K. D., & Seals, D. R. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)01054-8 · Cited by 3,775
Anaerobic threshold and respiratory gas exchange during exercise.
Wasserman, K., Whipp, B. J., Koyl, S. N., & Beaver, W. L. (1973) · Journal of Applied Physiology · doi:10.1152/jappl.1973.35.2.236 · Cited by 2,094
Validation of near-infrared spectroscopy in humans
Mancini, D. M., Bolinger, L., Li, H., Kendrick, K., Chance, B., & Wilson, J. R. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.6.2740 · Cited by 669
Critical power as a measure of physical work capacity and anaerobic threshold
MORITANI, T., NAGATA, A., DEVRIES, H. A., & MURO, M. (1981) · Ergonomics · doi:10.1080/00140138108924856 · Cited by 578
Anaerobic Threshold: The Concept and Methods of Measurement
Svedahl, K., & MacIntosh, B. R. (2003) · Canadian Journal of Applied Physiology · doi:10.1139/h03-023 · Cited by 472
Grassi, B., Pogliaghi, S., Rampichini, S., Quaresima, V., Ferrari, M., Marconi, C., & Cerretelli, P. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00695.2002 · Cited by 429
Self-citationValidity of criteria for establishing maximal O2 uptake during ramp exercise tests
Poole, D. C., Wilkerson, D. P., & Jones, A. M. (2008) · European Journal of Applied Physiology · doi:10.1007/s00421-007-0596-3 · Cited by 417
Billat, V. L., Sirvent, P., Py, G., Koralsztein, J.-P., & Mercier, J. (2003) · Sports Medicine · doi:10.2165/00007256-200333060-00003 · Cited by 397
DeLorey, D. S., Kowalchuk, J. M., & Paterson, D. H. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00956.2002 · Cited by 369
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Mortensen, S. P., Dawson, E. A., Yoshiga, C. C., Dalsgaard, M. K., Damsgaard, R., Secher, N. H., & González‐Alonso, J. (2005) · The Journal of Physiology · doi:10.1113/jphysiol.2005.086025 · Cited by 266
Methodological aspects of maximal lactate steady state-implications for performance testing
Beneke, R. (2003) · European Journal of Applied Physiology · doi:10.1007/s00421-002-0783-1 · Cited by 264
Billat, L. V. (1996) · Sports Medicine · doi:10.2165/00007256-199622030-00003 · Cited by 249
Blood lactate accumulation and muscle deoxygenation during incremental exercise
Grassi, B., Quaresima, V., Marconi, C., Ferrari, M., & Cerretelli, P. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.1.348 · Cited by 248
Maximal lactate steady state, respiratory compensation threshold and critical power
Dekerle, J., Baron, B., Dupont, L., Vanvelcenaher, J., & Pelayo, P. (2003) · European Journal of Applied Physiology · doi:10.1007/s00421-002-0786-y · Cited by 243
Maximal lactate steady state, critical power and EMG during cycling
Pringle, J., & Jones, A. (2002) · European Journal of Applied Physiology · doi:10.1007/s00421-002-0703-4 · Cited by 224
Bruce, R. A. (1974) · The American Journal of Cardiology · doi:10.1016/0002-9149(74)90211-2 · Cited by 197
Control of Blood Flow to Cardiac and Skeletal Muscle During Exercise
Laughlin, M. H., Korthuis, R. J., Duncker, D. J., & Bache, R. J. (1996) · Comprehensive Physiology · doi:10.1002/cphy.cp120116 · Cited by 188
Hamaoka, T., McCully, K. K., Niwayama, M., & Chance, B. (2011) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2011.0298 · Cited by 186
Effect of work rate on the functional ‘gain’ of Phase II pulmonary O2 uptake response to exercise
Wilkerson, D. P., Koppo, K., Barstow, T. J., & JONES, A. M. (2004) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2004.06.001 · Cited by 154
Dynamics of noninvasively estimated microvascular O2 extraction during ramp exercise
Ferreira, L. F., Koga, S., & Barstow, T. J. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01414.2006 · Cited by 130
Chin, L. M. K., Kowalchuk, J. M., Barstow, T. J., Kondo, N., Amano, T., Shiojiri, T., & Koga, S. (2011) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01216.2010 · Cited by 106
Blood flow and O2 extraction as a function of O2 uptake in muscles composed of different fiber types
Ferreira, L. F., McDonough, P., Behnke, B. J., Musch, T. I., & Poole, D. C. (2005) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2005.11.004 · Cited by 96
Characterizing the profile of muscle deoxygenation during ramp incremental exercise in young men
Spencer, M. D., Murias, J. M., & Paterson, D. H. (2012) · European Journal of Applied Physiology · doi:10.1007/s00421-012-2323-y · Cited by 96
Detection of ventilatory threshold using near infrared spectroscopy in men and women
BHAMBHANI, Y. N., BUCKLEY, S. M., & SUSAKI, T. (1997) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199703000-00017 · Cited by 89
Koga, S., Kano, Y., Barstow, T. J., Ferreira, L. F., Ohmae, E., Sudo, M., & Poole, D. C. (2012) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00925.2011 · Cited by 64
Which common NIRS variable reflects muscle estimated lactate threshold most closely?
Wang, L., Yoshikawa, T., Hara, T., Nakao, H., Suzuki, T., & Fujimoto, S. (2006) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h06-069 · Cited by 54
Effect of Exercise Protocol on Deoxy[Hb + Mb]: Incremental Step versus Ramp Exercise
BOONE, J., KOPPO, K., BARSTOW, T. J., & BOUCKAERT, J. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181c0ecea · Cited by 46
Terakado, S., Takeuchi, T., Miura, T., Sato, H., Nishioka, N., Fujieda, Y., Kobayashi, R., & Ibukiyama, C. (1999) · Japanese Circulation Journal · doi:10.1253/jcj.63.97 · Cited by 31
Moalla, W., Dupont, G., Berthoin, S., & Ahmaidi, S. (2005) · International Journal of Sports Medicine · doi:10.1055/s-2004-830332 · Cited by 30
Miura, T., Takeuchi, T., Sato, H., Nishioka, N., Terakado, S., Fujieda, Y., & Ibukiyama, C. (1998) · Japanese Circulation Journal · doi:10.1253/jcj.62.649 · Cited by 30
Soller, B. R., Yang, Y., Lee, S. M. C., Wilson, C., & Hagan, R. D. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00849.2007 · Cited by 29
Influence of priming exercise on muscle deoxy[Hb + Mb] during ramp cycle exercise
Boone, J., Bouckaert, J. J., Barstow, T. J., & Bourgois, J. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-011-2068-z · Cited by 28
Pogliaghi, S., Casiello, L., & Bandera, A. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000354914.23924.fd · Cited by 1
Self-citationAnaerobic Threshold Determination In Young Males: Can Nirs Help?
Pogliaghi, S., Bellotti, C., Roia, G. F. D., & Schena, F. F. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000386171.89913.9b · Cited by 1
Self-citation
Cited by
Grassi, B., & Quaresima, V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091313 · Cited by 345
“”(152) Most of these studies observed a nice correlation between NIRS-obtained indices and more traditional variables utilized to identify the various thresholds.(148,149,151,152) Broxterman et al.”
ResultA Critical Evaluation of Current Methods for Exercise Prescription in Women and Men
IANNETTA, D., INGLIS, E. C., MATTU, A. T., FONTANA, F. Y., POGLIAGHI, S., KEIR, D. A., & MURIAS, J. M. (2020) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000002147 · Cited by 236
“Depending on [La]b responses, the work rate for the subsequent constant-work rate trial was either decreased or increased by 10 W until the highest work rate with stable [La]b was established (28).”
BackgroundSelf-citationDose-Response Matters! - A Perspective on the Exercise Prescription in Exercise-Cognition Research
Herold, F., Müller, P., Gronwald, T., & Müller, N. G. (2019) · Frontiers in Psychology · doi:10.3389/fpsyg.2019.02338 · Cited by 196
Düking, P., Hotho, A., Holmberg, H.-C., Fuss, F. K., & Sperlich, B. (2016) · Frontiers in Physiology · doi:10.3389/fphys.2016.00071 · Cited by 181
Vascular responsiveness determined by near‐infrared spectroscopy measures of oxygen saturation
McLay, K. M., Fontana, F. Y., Nederveen, J. P., Guida, F. F., Paterson, D. H., Pogliaghi, S., & Murias, J. M. (2016) · Experimental Physiology · doi:10.1113/ep085406 · Cited by 127
“Within the last decade, near-infrared spectroscopy (NIRS) has become widely used to obtain measures of tissue oxygenation and haemodynamics at rest and during different exercise modalities and intensities (McCully et al. 1994; De Roia et al. 2012; Murias et al. 2012; Bellotti et al. 2013).”
MethodSelf-citation
Metadata
- Authors
- BELLOTTI, C., CALABRIA, E., CAPELLI, C., & POGLIAGHI, S.
- Affiliations
- University of Verona (IT)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2013-06
- Volume
- 45
- Issue
- 6
- Pages
- 1208-1216
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2316058784
- Semantic Scholar
- c8304dd1a61bba155d751c187203aa2804c02534
- Cited by
- 65
- References
- 41
- Citations by year
- 2026: 3 · 2025: 4 · 2024: 3 · 2023: 6 · 2022: 6 · 2021: 4 · 2020: 2 · 2019: 11 · 2018: 4 · 2017: 2 · 2016: 12 · 2015: 4 · 2014: 2 · 2013: 2
- FWCI
- 15.76
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- other-oa
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- Archivio Istituzionale della Ricerca (Universita Degli Studi Di Milano) (submittedVersion, other-oa)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Health Sciences › Medicine › Physiology (medical) › Exercise and Physiological Responses
- Keywords
- maximal lactate steady state, near-infrared spectroscopy, deoxyhemoglobin, muscle oxygen extraction, incremental cycling test, exercise intensity, oxygen consumption, heart rate, healthy adults
- MeSH terms
- Adult, Aged, Bicycling, Exercise Test, Hemoglobins, Humans, Male, Middle Aged, Anaerobic Threshold, Biomarkers, Exercise, Linear Models, Spectroscopy, Near-Infrared, Lactic Acid, Quadriceps Muscle, Healthy Volunteers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.