Determination of Maximal Lactate Steady State in Healthy Adults: Can NIRS Help?
Open accessThe DOI matches its Crossref record; 40 of the 41 references it cites were found in a registry or an index.
Abstract
PURPOSE: We tested the hypothesis that the maximal lactate steady state (MLSS) can be accurately determined in healthy subjects based on measures of deoxygenated hemoglobin (deoxyHb), an index of oxygen extraction measured noninvasively by near-infrared spectroscopy (NIRS). METHODS: Thirty-two healthy men (mean ± SD age = 48 ± 17 yr, range = 23-74 yr) performed an incremental cycling test to exhaustion and square wave tests for MLSS determination. Cardiorespiratory variables were measured bbb and deoxyHb was monitored noninvasively on the right vastus lateralis with a quantitative NIRS device. The individual values of V˙O2 and HR corresponding to the MLSS were calculated and compared to the NIRS-derived MLSS (NIRSMLSS) that was, in turn, determined by double linear function fitting of deoxyHb during the incremental exercise. RESULTS: V˙O2 and HR at MLSS were 2.25 ± 0.54 L·min (76% ± 9% V˙O2max) and 133 ± 14 bpm (81% ± 7% HRmax), respectively. Muscle O2 extraction increased as a function of exercise intensity up to a deflection point, NIRSMLSS, at which V˙O2 and HR were 2.23 ± 0.59 L·min (76% ± 9% V˙O2max) and 136 ± 17 bpm (82% ± 8% HRmax), respectively. For both V˙O2 and HR, the difference of NIRSMLSS from MLSS values was not significant and the measures were highly correlated (r = 0.81 and r = 0.76). The Bland-Altman analysis confirmed a nonsignificant bias for V˙O2 and HR (-0.015 L·min and 3 bpm, respectively) and a small imprecision of 0.26 L·min and 8 bpm. CONCLUSIONS: A plateau in muscle O2 extraction was demonstrated in coincidence with MLSS during an incremental cycling exercise, confirming the hypothesis that this functional parameter can be accurately estimated with a quantitative NIRS device. The main advantages of NIRSMLSS over lactate-based techniques are the noninvasiveness and the time/cost efficiency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“For instance, the [HHbMb] breakpoint during ramp exercise is suggested to resemble an upper limit of fractional oxygen extraction in the exercising leg muscles during incremental exercise [9–11] and approximates VT2 [10,12,11,13–15], maximal lactate steady state [14,16] and critical power [14].”
From Oxygenation Threshold Derived from Near-Infrared Spectroscopy: Reliability and Its Relationship with the First Ventilatory Threshold (2016) · cites this paper as [16]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“This plateau-like response has been associated with other physiological thresholds, especially those considered indicators of the maximal metabolic steady state, which delineate heavy and severe exercise domains (Bellotti et al. 2013; Keir et al. 2015, Turnes et al. 2019; Possamai et al. 2023).”
From Comparison of NIRS-derived [HHb] breakpoints and concordance with lactate thresholds during speed- and slope-based incremental running tests (2026) · cites this paper as Bellotti et al. 2013
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“During CW cycling exercise, SmO2 at the VL will rapidly deoxygenate before reaching a quasi-steady state within 60–120 s, similar to the primary onset phase of systemic V̇O2 kinetics (21, 22).”
From Comparing the reliability of muscle oxygen saturation with common performance and physiological markers across cycling exercise intensity (2023) · cites this paper as [22]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Multiple studies have validated various stationary NIRS sensors with each of the physiological and performance markers outlined above, during various modes of exercise (12, 17, 22, 29–31).”
From Comparing the reliability of muscle oxygen saturation with common performance and physiological markers across cycling exercise intensity (2023) · cites this paper as [22]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Plum, F. (1960) · Archives of Neurology · doi:10.1001/archneur.1960.03840090124020 · Cited by 10,364
(2014) · Medical Entomology and Zoology · Cited by 9,400
A new method for detecting anaerobic threshold by gas exchange
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.6.2020 · Cited by 4,103
Age-predicted maximal heart rate revisited
Tanaka, H., Monahan, K. D., & Seals, D. R. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)01054-8 · Cited by 3,775
Anaerobic threshold and respiratory gas exchange during exercise.
Wasserman, K., Whipp, B. J., Koyl, S. N., & Beaver, W. L. (1973) · Journal of Applied Physiology · doi:10.1152/jappl.1973.35.2.236 · Cited by 2,094
Validation of near-infrared spectroscopy in humans
Mancini, D. M., Bolinger, L., Li, H., Kendrick, K., Chance, B., & Wilson, J. R. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.6.2740 · Cited by 669
Critical power as a measure of physical work capacity and anaerobic threshold
MORITANI, T., NAGATA, A., DEVRIES, H. A., & MURO, M. (1981) · Ergonomics · doi:10.1080/00140138108924856 · Cited by 578
Anaerobic Threshold: The Concept and Methods of Measurement
Svedahl, K., & MacIntosh, B. R. (2003) · Canadian Journal of Applied Physiology · doi:10.1139/h03-023 · Cited by 472
Cited by
Grassi, B., & Quaresima, V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091313 · Cited by 345
“”(152) Most of these studies observed a nice correlation between NIRS-obtained indices and more traditional variables utilized to identify the various thresholds.(148,149,151,152) Broxterman et al.”
ResultA Critical Evaluation of Current Methods for Exercise Prescription in Women and Men
IANNETTA, D., INGLIS, E. C., MATTU, A. T., FONTANA, F. Y., POGLIAGHI, S., KEIR, D. A., & MURIAS, J. M. (2020) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000002147 · Cited by 236
“Depending on [La]b responses, the work rate for the subsequent constant-work rate trial was either decreased or increased by 10 W until the highest work rate with stable [La]b was established (28).”
BackgroundSelf-citationDose-Response Matters! - A Perspective on the Exercise Prescription in Exercise-Cognition Research
Herold, F., Müller, P., Gronwald, T., & Müller, N. G. (2019) · Frontiers in Psychology · doi:10.3389/fpsyg.2019.02338 · Cited by 196
Düking, P., Hotho, A., Holmberg, H.-C., Fuss, F. K., & Sperlich, B. (2016) · Frontiers in Physiology · doi:10.3389/fphys.2016.00071 · Cited by 181
Vascular responsiveness determined by near‐infrared spectroscopy measures of oxygen saturation
McLay, K. M., Fontana, F. Y., Nederveen, J. P., Guida, F. F., Paterson, D. H., Pogliaghi, S., & Murias, J. M. (2016) · Experimental Physiology · doi:10.1113/ep085406 · Cited by 127
“Within the last decade, near-infrared spectroscopy (NIRS) has become widely used to obtain measures of tissue oxygenation and haemodynamics at rest and during different exercise modalities and intensities (McCully et al. 1994; De Roia et al. 2012; Murias et al. 2012; Bellotti et al. 2013).”
MethodSelf-citationUsing ramp-incremental V̇O2 responses for constant-intensity exercise selection
Keir, D. A., Paterson, D. H., Kowalchuk, J. M., & Murias, J. M. (2018) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2017-0826 · Cited by 97
van der Zwaard, S., Jaspers, R. T., Blokland, I. J., Achterberg, C., Visser, J. M., den Uil, A. R., Hofmijster, M. J., Levels, K., Noordhof, D. A., de Haan, A., et al. (2016) · PLOS ONE · doi:10.1371/journal.pone.0162914 · Cited by 95
Boone, J., Barstow, T. J., Celie, B., Prieur, F., & Bourgois, J. (2016) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2015-0261 · Cited by 70
Boone, J., Vandekerckhove, K., Coomans, I., Prieur, F., & Bourgois, J. G. (2016) · European Journal of Applied Physiology · doi:10.1007/s00421-016-3468-x · Cited by 68
“…the threshold in integrated electromyography (EMG Th ), respiratory compensation point, maximal lactate steady state and/ or critical power (Osawa et al. 2011; Bellotti et al. 2013; Murias et al. 2013a, b; Racinais et al. 2014; Boone et al. 2015; Fontana et al. 2015; Boone et al. 2016) (Table 1).”
BackgroundMethodInfluentialMurias, J. M., Spencer, M. D., Keir, D. A., & Paterson, D. H. (2013) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00016.2013 · Cited by 67
KEIR, D. A., POGLIAGHI, S., & MURIAS, J. M. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001698 · Cited by 65
Self-citationFontana, F. Y., Keir, D. A., Bellotti, C., De Roia, G. F., Murias, J. M., & Pogliaghi, S. (2015) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2014.07.016 · Cited by 63
Self-citationRogers, B., & Gronwald, T. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.879071 · Cited by 82
“In terms of individual participant agreement between HRV and gas exchange/blood lactate derived thresholds, they appear to be of similar magnitude to that of other comparisons of threshold approaches such as blood lactate versus ventilatory parameters (Pallarés et al., 2016), assessment of gas exchange techniques for…”
BackgroundWearable Lactate Threshold Predicting Device is Valid and Reliable in Runners
Borges, N. R., & Driller, M. W. (2016) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000001307 · Cited by 59
“This study provides the first data on the validity and reliability of the WLT’s ability to predict lactate threshold in runners.”
BackgroundResultInfluentialSex-related differences in muscle deoxygenation during ramp incremental exercise
Murias, J. M., Keir, D. A., Spencer, M. D., & Paterson, D. H. (2013) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2013.08.011 · Cited by 55
Rogers, B., Giles, D., Draper, N., Mourot, L., & Gronwald, T. (2021) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk6020038 · Cited by 70
“Both the mean difference of −4 bpm and the LOA seen here are of similar magnitudes to that of a comparison of the MLSS and FTP [12] as well as the muscle oxygen desaturation breakpoint association to the MLSS [8].”
BackgroundResultInfluentialIannetta, D., Qahtani, A., Mattioni Maturana, F., & Murias, J. M. (2017) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2017.01.237 · Cited by 48
Caldwell, J. T., Wardlow, G. C., Branch, P. A., Gonzalez, M. R., Black, C. D., & Ade, C. J. (2016) · Physiological Reports · doi:10.14814/phy2.13032 · Cited by 49
“…to exercise steady state (i.e., NIRS kinetic response), the [HHb] response during ramp-incremental exercise varies as a function of continuous dynamic adjustments to changes in workload (Ferreira et al. 2007; Spencer et al. 2012; Bellotti et al. 2013; Fontana et al. 2015; Keir et al. 2015).”
BackgroundInglis, E. C., Iannetta, D., & Murias, J. M. (2017) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00261.2017 · Cited by 44
“55 This breakpoint in the [HHb] signal ([HHb]BP), has been indicated as a reliable measure (16) that can 56 be used as the demarcation point for the exercise intensity closely associated to the V̇O2 at the 57 respiratory compensation point (RCP) (11, 18) as well as the electromyography (EMG) threshold 58 (EMGt) (4, 24…”
MethodExercise Thresholds on Trial: Are They Really Equivalent?
CAEN, K., VERMEIRE, K., BOURGOIS, J. G., & BOONE, J. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001547 · Cited by 42
Boone, J., Barstow, T. J., Celie, B., Prieur, F., & Bourgois, J. (2015) · European Journal of Applied Physiology · doi:10.1007/s00421-014-2991-x · Cited by 41
Caen, K., Bourgois, J. G., Stassijns, E., & Boone, J. (2022) · European Journal of Applied Physiology · doi:10.1007/s00421-022-04942-2 · Cited by 41
“This breakpoint has been linked to an increased O2 provision, likely related to metabolic vasodilation and blood flow redistribution, and may indicate the attainment of an upper limit in muscle O2 extraction and a progressively larger contribution from non-oxidative energy turnover towards the end of a ramp test (Bell…”
BackgroundYogev, A., Arnold, J., Nelson, H., Clarke, D. C., Guenette, J. A., Sporer, B. C., & Koehle, M. S. (2023) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2023.1143393 · Cited by 49
“Frontiers in Sports and Active Living 02 During CW cycling exercise, SmO2 at the VL will rapidly deoxygenate before reaching a quasi-steady state within 60–120 s, similar to the primary onset phase of systemic V̇O2 kinetics (21, 22).”
BackgroundIannetta, D., Fontana, F. Y., Maturana, F. M., Inglis, E. C., Pogliaghi, S., Keir, D. A., & Murias, J. M. (2018) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2018.05.004 · Cited by 39
Self-citationPerrey, S. (2022) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2022.864825 · Cited by 53
“For constant-load heavy exercise, the maximal lactate steady state and critical power/speed were determined accurately by measuring the level of deoxygenated hemoglobin or StO2 (Snyder and Parmenter, 2009; Bellotti et al., 2013; Feldmann and Erlacher, 2021).”
MethodInfluentialSchaffarczyk, M., Rogers, B., Reer, R., & Gronwald, T. (2022) · European Journal of Applied Physiology · doi:10.1007/s00421-022-05050-x · Cited by 44
Determination of Second Lactate Threshold Using Near-infrared Spectroscopy in Elite Cyclists
Salas-Montoro, J.-A., Mateo-March, M., Sánchez-Muñoz, C., & Zabala, M. (2022) · International Journal of Sports Medicine · doi:10.1055/a-1738-0252 · Cited by 27
“To accurately determine the MLSS, the gold standard method requires 30 minutes continuous exercise bouts over multiples days at different but constant intensities [14,15], which is expensive [5].”
BackgroundMethodResultKlusiewicz, A., Rębiś, K., Ozimek, M., & Czaplicki, A. (2021) · Biology of Sport · doi:10.5114/biolsport.2021.103571 · Cited by 24
Inglis, E. C., Iannetta, D., Keir, D. A., & Murias, J. M. (2020) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2019-0046 · Cited by 21
Turnes, T., Penteado dos Santos, R., de Aguiar, R. A., Loch, T., Possamai, L. T., & Caputo, F. (2019) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2018-0675 · Cited by 19
Multimodal Wearable Platform with Simultaneous Electrochemical and Biophotonic Sensing
Evert, B., Peterson, K., Songkakul, T., Bozkurt, A. Y., & Daniele, M. A.-A. (2025) · ACS Sensors · doi:10.1021/acssensors.4c03492 · Cited by 20
Aerobic Interval Training Impacts Muscle and Brain Oxygenation Responses to Incremental Exercise
Caen, K., Vermeire, K., Pogliaghi, S., Moerman, A., Niemeijer, V. M., Bourgois, J., & Boone, J. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.01195 · Cited by 24
“The NIRS data (O2Hb, HHb, tHb, and TOI) were averaged into 10s-bins, expressed as function of power output and analyzed using a double-linear model (Osawa et al., 2011; Bellotti et al., 2013; Boone et al., 2015) (Sigmaplot 13, Systat Software Inc.”
MethodSelf-citationAcute Effects of Plyometric and Resistance Training on Running Economy in Trained Runners
Marcello, R. T., Greer, B. K., & Greer, A. E. (2016) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000001705 · Cited by 24
“It was a general assumption that an intensity of 80% V̇O2 peak would be below lactate threshold for the highly trained subject pool (Bellotti et al., 2013).”
BackgroundSendra-Pérez, C., Encarnacion-Martinez, A., Salvador-Palmer, R., Murias, J. M., & Priego-Quesada, J. I. (2025) · European Journal of Applied Physiology · doi:10.1007/s00421-024-05593-1 · Cited by 16
“…2022; Iannetta et al. 2017a, b; Rodrigo-Carranza et al. 2021; Salas-Montoro et al. 2022), some of which have been associated to metabolic boundaries (i.e., thresholds) separating exercise intensity domains (Bellotti et al. 2013; Feldmann et al. 2022; Keir et al. 2015a; Sendra-Pérez et al. 2023b).”
Fat Oxidation Kinetics Is Related to Muscle Deoxygenation Kinetics During Exercise
Zurbuchen, A., Lanzi, S., Voirol, L., Trindade, C. B., Gojanovic, B., Kayser, B., Bourdillon, N., Chenevière, X., & Malatesta, D. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2020.00571 · Cited by 20
Evaluating a new wearable lactate threshold sensor in recreational to highly trained cyclists
Driller, M., Borges, N., & Plews, D. (2016) · Sports Engineering · doi:10.1007/s12283-016-0198-6 · Cited by 15
Soares, R. N., Colosio, A. L., Murias, J. M., & Pogliaghi, S. (2019) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2018-0866 · Cited by 18
Self-citationInglis, E. C., Iannetta, D., & Murias, J. M. (2019) · PLoS ONE · doi:10.1371/journal.pone.0220192 · Cited by 15
Azevedo, R. D. A., E., B. S. J., Inglis, E. C., Iannetta, D., & Murias, J. M. (2020) · Physiological Reports · doi:10.14814/phy2.14478 · Cited by 18
Local muscle oxygen consumption related to external and joint specific power
Skovereng, K., Ettema, G. J. C., & Beekvelt, M. C. P. V. (2015) · Human Movement Science · doi:10.1016/j.humov.2015.11.009 · Cited by 15
Influence of type 2 diabetes on muscle deoxygenation during ramp incremental cycle exercise
Gildea, N., Rocha, J., McDermott, A., O'Shea, D. B., Green, S., & Egaña, M. (2019) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2019.103258 · Cited by 13
Stuer, L., Teso, M., Colosio, A. L., Loi, M., Mucci, P., Pogliaghi, S., Boone, J., & Caen, K. (2024) · European Journal of Applied Physiology · doi:10.1007/s00421-024-05654-5 · Cited by 13
“Additionally, NIRS has also been suggested as an alternative for threshold determination (Bellotti et al. 2013; Snyder and Parmenter 2009).”
Self-citationFleitas‐Paniagua, P. R., Azevedo, R. D. A., Trpcic, M., Murias, J. M., & Rogers, B. (2023) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000004597 · Cited by 15
“Within the past 2 decades, the use of the deoxygenated hemoglobin signal ([HHb]) from near-infrared spectroscopy (NIRS) and measures of heart rate variability (HRV) have been proposed to estimate the critical intensity in a single laboratory visit using less-expensive equipment (6,42).”
BackgroundInfluentialVandekerckhove, K., Coomans, I., Moerman, A., Wolf, D. D., & Boone, J. (2016) · European Journal of Applied Physiology · doi:10.1007/s00421-016-3486-8 · Cited by 11
Wearable near Infrared Sensor for Determining an Athlete's Lactate Threshold during Exercise
Driller, M., Plews, D., & Borges, N. (2016) · NIR news · doi:10.1255/nirn.1609 · Cited by 9
Possamai, L. T., Borszcz, F. K., de Aguiar, R. A., Lucas, R. D. D., & Turnes, T. (2024) · Biology of Sport · doi:10.5114/biolsport.2024.129486 · Cited by 9
Rogers, B., Schaffarczyk, M., & Gronwald, T. (2023) · Sensors · doi:10.3390/s23041973 · Cited by 14
Peinado, A. B., Filho, D. M. P., Díaz, V., Benito, P. J., Álvarez-Sánchez, M., Zapico, A. G., & Calderón, F. (2016) · Biology of Sport · doi:10.5604/20831862.1221812 · Cited by 13
“…points during an incremental test have been proposed as intensities that indicate MLSS, which would permit its determination with one single test [1, 15, 19, 25, 27, 28, 52-55], none of these studies is definitive, and the challenge remains to be able to determine this intensity with just one test.”
BackgroundFontana, F. Y., Colosio, A. L., Keir, D. A., Murias, J. M., & Pogliaghi, S. (2016) · Journal of Sports Sciences · doi:10.1080/02640414.2016.1261177 · Cited by 10
Self-citationEasy Prediction of the Maximal Lactate Steady-State in Young and Older Men and Women
Pogliaghi, S., Teso, M., Ferrari, L., Boone, J., Murias, J. M., & Colosio, A. L. (2023) · Journal of Sports Science and Medicine · doi:10.52082/jssm.2023.68 · Cited by 6
Self-citationMUSCLE OXYGENATION OF THE QUADRICEPS AND GASTROCNEMIUS DURING MAXIMAL AEROBIC EFFORT
Paredes-Ruiz, M.-J., Jódar-Reverte, M., Ferrer-López, V., & González-Moro, I. M. (2021) · Revista Brasileira de Medicina do Esporte · doi:10.1590/1517-8692202127022020_0076 · Cited by 7
Lubiak, S. M., Proppe, C. E., Rivera, P. M., Howard, M. A., Prajapati, A. J., Shah, N. M., Patel, N. N., Schmidt, J. T., Zak, R., & Hill, E. C. (2025) · European Journal of Applied Physiology · doi:10.1007/s00421-025-05886-z · Cited by 2
“The NIRS-derived StO 2 signal reflects muscle tissue oxygen transport, extraction, and utilization (Barstow 2019) and has previously been used to indirectly estimate metabolite accumulation (Bellotti et al. 2013; Keller et al. 2022).”
Vasquez-Bonilla, A. A., Camacho-Cardeñosa, A., Camacho-Cardeñosa, M., Martínez‐Guardado, I., Timón, R., & Olcina, G. J. (2016) · RICYDE Revista Internacional de Ciencias del Deporte · doi:10.5232/ricyde2017.04705 · Cited by 2
Validity of a Muscle Specific Method to Evaluate the Anaerobic Threshold in Exercised Muscles
Popov, D. V., Kuznetsov, S. Y., Orlova, E. A., Sharova, A. P., Боровик, А. С., & Виноградова, О. Л. (2019) · Human Physiology · doi:10.1134/s0362119719020087 · Cited by 2
Ventura, T. P., Borszcz, F. K., Aguiar, R. A. D., de Lucas, R. D., & Turnes, T. (2026) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2025-0240 · Cited by 3
Estimation of the maximal lactate steady state in postmenopausal women
Gil‐Rey, E., Maldonado‐Martín, S., Samper, N. P., & Gorostiaga, E. M. (2019) · Journal of Sports Sciences · doi:10.1080/02640414.2019.1586814 · Cited by 4
“This value is among the highest reported in the literature (55–88%) (Bellotti et al., 2013; Faude et al., 2009; Garcia-Tabar & Gorostiaga, 2018; Llodio et al., 2015; Pallarés et al., 2016; Pardono et al., 2008).”
BackgroundInfluentialRomarate, A., Jauregi, A. P., Feldmann, A., Viribay, A., & Santos‐Concejero, J. (2025) · European Journal of Sport Science · doi:10.1002/ejsc.70025 · Cited by 2
“� Near‐infrared spectroscopy technology is useful for coaches without time to do complicated analyses. compared maximal lactate steady state (MLSS) with detection using NIRS technology and concluded that MLSS can be accurately detected using NIRS technology (Bellotti et al. 2013).”
InfluentialPolito, L. F. T., Marquezi, M. L., Marin, D. P., Boas, M. V., & Brandão, M. R. F. (2021) · Frontiers in Psychology · doi:10.3389/fpsyg.2020.623480 · Cited by 2
“These parameters can be analyzed by the physiological variables such as the oxygen consumption (VO2), the heart rate (HR), the ventilator anaerobic thresholds, blood lactate concentration (Bellotti et al., 2013), and by psychophysiological variables such as the ratings of perceived exertion (RPE) (Borg, 1962), the tot…”
BackgroundBeziehung zwischen Laktat- und anderen Schwellenkonzepten
Heck, H., & Bartmus, U. (2022) · Springer eBooks · doi:10.1007/978-3-662-59835-1_10 · Cited by 1
Information technologies in training process modelling
Plećaš, J. (2019) · TIMS Acta · doi:10.5937/timsacta1902089p
Piñero-Saez, S., LOPEZ, A., Guisado-Requena, I. M., López-Tendero, J., Guerrero-Agenjo, C. M., González-Moro, I. M., Rabanales-Sotos, J., & García-Alcaráz, F. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4632540
Muscle Near-Infrared Spectroscopy: mNIRS the Next Generation of Applied Muscle Physiology
Feldmann, A. (2024) · Springer eBooks · doi:10.1007/978-3-662-68241-8_17-1 · Cited by 1
Muscle Near-Infrared Spectroscopy: mNIRS the Next Generation of Applied Muscle Physiology
Feldmann, A. (2025) · Springer eBooks · doi:10.1007/978-3-662-70475-2_17 · Cited by 1
Lubiak, S. M., Proppe, C. E., Rivera, P. M., Howard, M. A., Prajapati, A. J., Shah, N. M., Patel, N. N., Zak, R., Perlet, M. R., Pennartz, K. J., et al. (2026) · Physiology International · doi:10.1556/2060.2025.00711
Muscle Near-Infrared Spectroscopy: mNIRS the Next Generation of Applied Muscle Physiology
Feldmann, A. (2026) · Springer eBooks · doi:10.1007/978-3-662-73013-3_14
Metadata
- Authors
- BELLOTTI, C., CALABRIA, E., CAPELLI, C., & POGLIAGHI, S.
- Affiliations
- University of Verona (IT)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2013-06
- Volume
- 45
- Issue
- 6
- Pages
- 1208-1216
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2316058784
- Semantic Scholar
- c8304dd1a61bba155d751c187203aa2804c02534
- Cited by
- 65
- References
- 41
- Citations by year
- 2026: 3 · 2025: 4 · 2024: 3 · 2023: 6 · 2022: 6 · 2021: 4 · 2020: 2 · 2019: 11 · 2018: 4 · 2017: 2 · 2016: 12 · 2015: 4 · 2014: 2 · 2013: 2
- FWCI
- 15.76
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- other-oa
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- Archivio Istituzionale della Ricerca (Universita Degli Studi Di Milano) (submittedVersion, other-oa)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Health Sciences › Medicine › Physiology (medical) › Exercise and Physiological Responses
- Keywords
- maximal lactate steady state, near-infrared spectroscopy, deoxyhemoglobin, muscle oxygen extraction, incremental cycling test, exercise intensity, oxygen consumption, heart rate, healthy adults
- MeSH terms
- Adult, Aged, Bicycling, Exercise Test, Hemoglobins, Humans, Male, Middle Aged, Anaerobic Threshold, Biomarkers, Exercise, Linear Models, Spectroscopy, Near-Infrared, Lactic Acid, Quadriceps Muscle, Healthy Volunteers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.