Classification Accuracy of the Wrist-Worn Gravity Estimator of Normal Everyday Activity Accelerometer
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
PURPOSE: The purpose of this study was to determine whether the published left-wrist cut points for the triaxial Gravity Estimator of Normal Everyday Activity (GENEA) accelerometer are accurate for predicting intensity categories during structured activity bouts. METHODS: A convenience sample of 130 adults wore a GENEA accelerometer on their left wrist while performing 14 different lifestyle activities. During each activity, oxygen consumption was continuously measured using the Oxycon mobile. Statistical analysis used Spearman's rank correlations to determine the relationship between measured and estimated intensity classifications. Cross tabulations were constructed to show the under- or overestimation of misclassified intensities. One-way χ2 tests were used to determine whether the intensity classification accuracy for each activity differed from 80%. RESULTS: For all activities, the GENEA accelerometer-based physical activity monitor explained 41.1% of the variance in energy expenditure. The intensity classification accuracy was 69.8% for sedentary activities, 44.9% for light activities, 46.2% for moderate activities, and 77.7% for vigorous activities. The GENEA correctly classified intensity for 52.9% of observations when all activities were examined; this increased to 61.5% with stationary cycling removed. CONCLUSIONS: A wrist-worn triaxial accelerometer has modest-intensity classification accuracy across a broad range of activities when using the cut points of Esliger et al. Although the sensitivity and the specificity are less than those reported by Esliger et al., they are generally in the same range as those reported for waist-worn, uniaxial accelerometer cut points.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2011 Compendium of Physical Activities: A Second Update of Codes and MET Values
AINSWORTH, B. E., HASKELL, W. L., HERRMANN, S. D., MECKES, N., BASSETT, D. R., TUDOR-LOCKE, C., GREER, J. L., VEZINA, J., WHITT-GLOVER, M. C., & LEON, A. S. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31821ece12 · Cited by 6,317 · cited 3×
“The values we obtained were in close agreement with values predicted by the Compendium of Physical Activities (1) (see Table 1).”
MethodResultSelf-citationCalibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
Self-citationComparison of Accelerometer Cut Points for Predicting Activity Intensity in Youth
TROST, S. G., LOPRINZI, P. D., MOORE, R., & PFEIFFER, K. A. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318206476e · Cited by 1,360
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Self-citationBest Practices for Using Physical Activity Monitors in Population-Based Research
MATTHEWS, C. E., HAGSTRÖMER, M., POBER, D. M., & BOWLES, H. R. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399e5b · Cited by 703
Validation of the GENEA Accelerometer
ESLIGER, D. W., ROWLANDS, A. V., HURST, T. L., CATT, M., MURRAY, P., & ESTON, R. G. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31820513be · Cited by 625 · cited 11×
“(9) are accurate for predicting intensity categories.”
BackgroundMethodInfluentialPhysical Activity Classification Using the GENEA Wrist-Worn Accelerometer
ZHANG, S., ROWLANDS, A. V., MURRAY, P., & HURST, T. L. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31823bf95c · Cited by 233
Protocols for evaluating equivalency of accelerometry-based activity monitors
WELK, G. J., MCCLAIN, J., & AINSWORTH, B. E. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399d8f · Cited by 124 · cited 1×
“Our activities represented a wide range of MET levels and included ambulatory, household, office, and sport activities, as is appropriate for an activity monitor calibration study (10,28).”
BackgroundValidity of 2 Devices for Measuring Steps Taken by Older Adults in Assisted-Living Facilities
Bergman, R. J., Bassett, D. R., & Klein, D. A. (2008) · Journal of Physical Activity and Health · doi:10.1123/jpah.5.s1.s166 · Cited by 62
Self-citation
Cited by
van Hees, V. T., Fang, Z., Langford, J., Assah, F., Mohammad, A., da Silva, I. C. M., Trenell, M. I., White, T., Wareham, N. J., & Brage, S. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00421.2014 · Cited by 676
Sabia, S., van Hees, V. T., Shipley, M. J., Trenell, M. I., Hagger-Johnson, G., Elbaz, A., Kivimaki, M., & Singh-Manoux, A. (2014) · American Journal of Epidemiology · doi:10.1093/aje/kwt330 · Cited by 304
Willetts, M., Hollowell, S., Aslett, L., Holmes, C., & Doherty, A. (2018) · Scientific Reports · doi:10.1038/s41598-018-26174-1 · Cited by 250
“This approach provides an automated analysis of objectively measured behavioural variation in lifestyle behaviours and can be used by researchers to study social and health behaviours at a resolution not previously available.”
Field evaluation of a random forest activity classifier for wrist-worn accelerometer data
Pavey, T. G., Gilson, N. D., Gomersall, S. R., Clark, B., & Trost, S. G. (2017) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2016.06.003 · Cited by 174
Performance of activity classification algorithms in free-living older adults
SASAKI, J. E., HICKEY, A. M., STAUDENMAYER, J. W., JOHN, D., KENT, J. A., & FREEDSON, P. S. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000844 · Cited by 112
“Similar to previous studies, 80% of the correct classification rate was considered an acceptable accuracy level for our algorithms (15,17,19).”
ResultSelf-citation
Metadata
- Authors
- WELCH, W. A., BASSETT, D. R., THOMPSON, D. L., FREEDSON, P. S., STAUDENMAYER, J. W., JOHN, D., STEEVES, J. A., CONGER, S. A., CEASER, T., HOWE, C. A., SASAKI, J. E., & FITZHUGH, E. C.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2013-10
- Volume
- 45
- Issue
- 10
- Pages
- 2012-2019
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2106016438
- Cited by
- 66
- References
- 9
- FWCI
- 4.28
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.