CoChat

Use of Accelerometry to Classify Activity Beneficial to Bone in Premenopausal Women

STILES, VICTORIA H., GRIEW, PIPPA J., ROWLANDS, ALEX V. · 2013 · Medicine & Science in Sports & Exercise
Cited by 36

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

PURPOSE: The aims of this study were to quantify the relation between ground reaction force (GRF) and peak acceleration from hip- and wrist-worn accelerometers and determine peak acceleration cut-points associated with a loading rate previously demonstrated as beneficial to bone (43 body weights (BW)·s⁻¹) in premenopausal women. METHODS: Forty-seven premenopausal women (age, 39.2 ± 5.6 yr; mass, 65.9 ± 11.0 kg; height, 1.67 ± 0.06 m) performed walking (slow, fast, and with bag), floor sweeping, running (slow and fast), jumping (low, <5 cm; high, >5 cm), and box drop (20 cm) trials. Peak accelerations were sampled at 100 Hz by GENEActiv and ActiGraph GT3X+ accelerometers (ActiGraph LLC, Pensacola, FL) worn at the hip (vertical and resultant) and the wrist (resultant). A force plate (960 Hz, AMTI) was used to assess peak vertical GRF and peak loading rate for eight steps per activity. Receiver operating characteristic curves were used to determine the optimal peak acceleration cut-points associated with a loading rate of 43 BW·s⁻¹ in 37 participants, and these cut-points were cross-validated in the remaining 10 participants. RESULTS: For all activities combined, peak accelerations were positively and significantly (P < 0.001) correlated with peak vertical GRF (hip r > 0.8, wrist r > 0.7) and peak loading rate (hip r > 0.7, wrist r > 0.57). Irrespective of monitor type and wear site, peak acceleration discriminated between loading rates above and below 43 BW·s⁻¹ with high levels of accuracy (area under the curve >0.92, P < 0.001). Overall classification agreement was >85% for both monitors worn at either the wrist or hip in the cross-validation sample. CONCLUSION: GENEActiv and ActiGraph GT3X+ accelerometers worn at the wrist or hip can be used as an unobtrusive tool to identify the occurrence of loading rates likely beneficial to bone in premenopausal women during their daily activity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/mss.0b013e31829ba765

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 36

Metadata

Authors
STILES, V. H., GRIEW, P. J., & ROWLANDS, A. V.
Venue
Medicine & Science in Sports & Exercise
Published
2013-12
Volume
45
Issue
12
Pages
2353-2361
ISSN
0195-9131 (ISSN-L)
OpenAlex
W1967179129
Cited by
36
References
5
FWCI
1.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of Accelerometry to Classify Activity Beneficial to Bone in Premenopausal Women. https://app.cochat.ai/papers/10.1249/mss.0b013e31829ba765
The paper
STILES, V. H., GRIEW, P. J., & ROWLANDS, A. V. (2013). Use of Accelerometry to Classify Activity Beneficial to Bone in Premenopausal Women. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/mss.0b013e31829ba765

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.