Integral Value of JT Interval in Magnetocardiography is Sensitive to Coronary Stenosis and Improves Soon After Coronary Revascularization

Open access
On, Kei, Watanabe, Shigeyuki, Yamada, Satsuki, Takeyasu, Noriyuki, Nakagawa, Yoshitsugu, Nishina, Hidetaka, Morimoto, Takafumi, Aihara, Hideaki, Kimura, Taizo, Sato, Yoko, Tsukada, Keiji, Kandori, Akihiko, Miyashita, Tsuyoshi, Ogata, Kuniomi, Suzuki, Daisuke, Yamaguchi, Iwao, Aonuma, Kazutaka · 2007 · Circulation Journal
Cited by 32

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Magnetocardiography (MCG) is sensitive to minute cardiac electric abnormalities, but its clinical utility in diagnosing ischemic heart disease (IHD) has not been established. The present study examined the usefulness of an integral MCG value of ventricular repolarization in patients with IHD. METHODS AND RESULTS: MCG was performed at rest in 14 patients with coronary stenosis >75% confirmed by coronary angiography (IHD group) using a 64-channel system, and then the sum of the 64-channel integral values of the QRS or JT intervals (QRSi and JTi, respectively) was calculated. The JTi/QRSi value indicated the total power of currents in JT compared with those in QRS. These measurements were repeated within 2 weeks after coronary revascularization. The Control group comprised 30 healthy volunteers. The baseline value of JTi/QRSi was significantly smaller in the IHD than in the Control group, but after revascularization it increased and did not significantly differ from the Control group. No significant difference in ST deviation was identified by electrocardiography (ECG) before and after coronary revascularization. Analysis of the Control group revealed that JTi/QRSi was not affected by age. CONCLUSIONS: The JTi/QRSi of the MCG is more sensitive to coronary stenosis than ECG, and this parameter improves soon after coronary revascularization.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1253/circj.71.1586

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 32

Metadata

Authors
On, K., Watanabe, S., Yamada, S., Takeyasu, N., Nakagawa, Y., Nishina, H., Morimoto, T., Aihara, H., Kimura, T., Sato, Y., Tsukada, K., Kandori, A., Miyashita, T., Ogata, K., Suzuki, D., Yamaguchi, I., & Aonuma, K.
Venue
Circulation Journal
Published
2007
Volume
71
Issue
10
Pages
1586-1592
ISSN
  • 1346-9843 (ISSN-L)
  • 1347-4820
OpenAlex
W2015006354
Cited by
32
References
6
FWCI
1.73
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Integral Value of JT Interval in Magnetocardiography is Sensitive to Coronary Stenosis and Improves Soon After Coronary Revascularization. https://app.cochat.ai/papers/10.1253/circj.71.1586
The paper
On, K., Watanabe, S., Yamada, S., Takeyasu, N., Nakagawa, Y., Nishina, H., Morimoto, T., Aihara, H., Kimura, T., Sato, Y., Tsukada, K., Kandori, A., Miyashita, T., Ogata, K., Suzuki, D., Yamaguchi, I., & Aonuma, K. (2007). Integral Value of JT Interval in Magnetocardiography is Sensitive to Coronary Stenosis and Improves Soon After Coronary Revascularization. Circulation Journal. https://doi.org/10.1253/circj.71.1586

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.