Utility of High-Resolution Magnetocardiography to Predict Later Cardiac Events in Nonischemic Cardiomyopathy Patients With Normal QRS Duration
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Nonischemic dilated cardiomyopathy (NIDCM) patients, even those with a narrow QRS, are at increased risk for major adverse cardiac events (MACE). We hypothesized that 64-channel magnetocardiography (MCG) would be useful to detect prognostic left intraventricular disorganized conduction (LiDC) by overcoming the limitations of fragmented QRS (fQRS, qualitative definitions, low specificity) and late potential (abnormality undetectable in earlier QRS). METHODS AND RESULTS: We evaluated LiDC on MCG, defined as significant deviation from a global clockwise left ventricular (LV) activation pattern, and conventional noninvasive predictors of MACE, including fQRS and late potential, in 51 NIDCM patients with narrow QRS (LV ejection fraction, 22±7%; QRS duration, 99±11 ms). MACE was defined as cardiac death, lethal ventricular arrhythmias, or LV assist device (LVAD) implantation. LiDC was present in 22 patients. Baseline characteristics were comparable between patients with and without LiDC, except for the ratio of positive late potential. During a mean follow-up of 2.9 years, MACE developed in 16 NIDCM patients (3 cardiac deaths, 9 lethal ventricular arrhythmias, and 4 LVAD). MACE was more incident in patients with LiDC (13/22) than in those without (3/29, P<0.001). Multivariate analysis revealed LiDC, but not fQRS or late potential, as the strongest independent predictor of MACE (hazard ratio 4.28, 95% confidence interval 1.30-19.39, P=0.015). CONCLUSIONS: MCG accurately depicts LiDC, a promising noninvasive predictor of MACE in patients with NIDCM and normal QRS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Peters, S., Trümmel, M., & Koehler, B. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.07.012 · Cited by 155
Kwong, J. S. W., Leithäuser, B., Park, J.-W., & Yu, C.-M. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.12.056 · Cited by 103
KORHONEN, P., HUSA, T., TIERALA, I., VÄÄNÄNEN, H., MÄKIJÄRVI, M., KATILA, T., & TOIVONEN, L. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.00332.x · Cited by 51
Cited by
Millimetre-scale magnetocardiography of living rats with thoracotomy
Arai, K., Kuwahata, A., Nishitani, D., Fujisaki, I., Matsuki, R., Nishio, Y., Xin, Z., Cao, X., Hatano, Y., Onoda, S., et al. (2022) · Communications Physics · doi:10.1038/s42005-022-00978-0 · Cited by 85
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Kurashima, K., Kataoka, M., Nakano, T., Fujiwara, K., Kato, S., Nakamura, T., Yuzawa, M., Masuda, M., Ichimura, K., Okatake, S., et al. (2023) · Sensors · doi:10.3390/s23020646 · Cited by 56
“Moreover, relationships between the abnormality in the spatial mappings of heart magnetic fields obtained with magnetocardiography and Brugada syndrome [8], left intraventricular disorganized conduction in patients with dilated cardiomyopathy [9], right ventricular cardiomyopathy [10] and malignant arrhythmias [11] ha…”
BackgroundSorbo, A. R., Lombardi, G., La Brocca, L., Guida, G., Fenici, R., & Brisinda, D. (2018) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12526 · Cited by 18
“, 2001), a standardization adequate for clinical application is still missing, especially taking into account the potential source of error due to different S/Nr and/or sequential data acquisition (Bang et al., 2016; Hänninen et al., 2002; Kawakami et al., 2017; Mäkijärvi et al., 2010; Shin et al., 2015) as occurs wit…”
BackgroundInfluentialBrisinda, D., Fenici, R., & Smars, P. (2022) · Contemporary Cardiology · doi:10.1007/978-3-031-05520-1_17 · Cited by 6
Metadata
- Authors
- Kawakami, S., Takaki, H., Hashimoto, S., Kimura, Y., Nakashima, T., Aiba, T., Kusano, K. F., Kamakura, S., Yasuda, S., & Sugimachi, M.
- Venue
- Circulation Journal
- Publisher
- Japanese Circulation Society
- Published
- 2017
- Volume
- 81
- Issue
- 1
- Pages
- 44-51
- ISSN
- 1346-9843 (ISSN-L)
- 1347-4820
- OpenAlex
- W2553532804
- Cited by
- 27
- References
- 3
- FWCI
- 1.49
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Utility of High-Resolution Magnetocardiography to Predict Later Cardiac Events in Nonischemic Cardiomyopathy Patients With Normal QRS Duration. https://app.cochat.ai/papers/10.1253/circj.cj-16-0683
- The paper
- Kawakami, S., Takaki, H., Hashimoto, S., Kimura, Y., Nakashima, T., Aiba, T., Kusano, K. F., Kamakura, S., Yasuda, S., & Sugimachi, M. (2017). Utility of High-Resolution Magnetocardiography to Predict Later Cardiac Events in Nonischemic Cardiomyopathy Patients With Normal QRS Duration. Circulation Journal. https://doi.org/10.1253/circj.cj-16-0683
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.