Abstract
The performance of three different types of mass spectrometer (MS) coupled to high performance liquid chromatography (HPLC), was compared for trace analysis of perfluoroalkylated substances (PFAS) and fluorotelomer alcohols (FTOHs). An ion trap MS in the full-scan and product-ion mass spectrometry (MS 2) mode, time-of-flight (ToF) high-resolution MS and quadrupole MS in the selected ion mode, as well as triple quadrupole tandem MS were tested. Electrospray ionisation in the negative-ion mode [ESI(–)] was best suited for all instruments and compounds. PFAS could only be separated by a buffered mobile phase, but the presence of buffer suppressed the ionisation of FTOHs. Therefore, two independent chromatographic methods were developed for the two compound classes. Mass spectra and product-ion spectra obtained by in-source and collision-induced dissociation fragmentation are discussed, including ion adduct formation. Product ion yields of PFAS were only in the range of 0.3 to 12%, independent of the applied MS instrument. Ion trap MS 2 gave product ion yields of 20 to 62% for FTOHs, whereas only 4.1 to 5.8% were obtained by triple quadrupole tandem MS. Ion trap MS was best suited for qualitative analysis and structure elucidation of branched isomeric structures of PFAS. Providing typical detection limits of 5 ng injected in MS 2 mode, it was not sensitive enough for selective trace amount quantification. ToF high-resolution MS was the only technique combining high selectivity and excellent sensitivity for PFAS analysis (detection limits of 2 to 10 pg), but lacked the possibilities of MS/MS. Triple-quadrupole tandem MS was the method of choice for quantification of FTOHs with detection limits in the low pg range. It is also well suited for the determination of PFAS, although its detection limits of 10 to 100 pg in tandem MS mode are about one order of magnitude higher than for ToF MS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Global Distribution of Perfluorooctane Sulfonate in Wildlife
Giesy, J. P., & Kannan, K. (2001) · Environmental Science & Technology · doi:10.1021/es001834k · Cited by 2,750
Compound-specific, quantitative characterization of organic fluorochemicals in biological matrices
Hansen, K. J., Clemen, L. A., Ellefson, M. E., & Johnson, H. O. (2001) · Environmental Science & Technology · doi:10.1021/es001489z · Cited by 923
Martin, J. W., Muir, D. C. G., Moody, C. A., Ellis, D. A., Kwan, W. C., Solomon, K. R., & Mabury, S. A. (2002) · Analytical Chemistry · doi:10.1021/ac015630d · Cited by 299
Cited by
Polyfluoroalkyl compounds in the aquatic environment: a review of their occurrence and fate
Ahrens, L. (2011) · J. Environ. Monit. · doi:10.1039/c0em00373e · Cited by 759
The overlooked short- and ultrashort-chain poly- and perfluorinated substances: A review
Ateia, M., Maroli, A., Tharayil, N., & Karanfil, T. (2019) · Chemosphere · doi:10.1016/j.chemosphere.2018.12.186 · Cited by 639
(EFSA), E. F. S. A. (2008) · EFSA Journal · doi:10.2903/j.efsa.2008.653 · Cited by 527
Microbial degradation of polyfluoroalkyl chemicals in the environment: A review
Liu, J., & Mejia Avendaño, S. (2013) · Environment International · doi:10.1016/j.envint.2013.08.022 · Cited by 525
Haug, L. S., Huber, S., Becher, G., & Thomsen, C. (2011) · Environment International · doi:10.1016/j.envint.2011.01.011 · Cited by 391
Metadata
- Authors
- Berger, U., Langlois, I., Oehme, M., & Kallenborn, R.
- Venue
- European Journal of Mass Spectrometry
- Publisher
- SAGE Publications
- Published
- 2004-10
- Volume
- 10
- Issue
- 5
- Pages
- 579-588
- ISSN
- 1356-1049 (ISSN-L)
- 1469-0667
- 1751-6838
- OpenAlex
- W2008199301
- Cited by
- 83
- References
- 3
- FWCI
- 2.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Three Types of Mass Spectrometer for High-Performance Liquid Chromatography/Mass Spectrometry Analysis of Perfluoroalkylated Substances and Fluorotelomer Alcohols. https://app.cochat.ai/papers/10.1255/ejms.679
- The paper
- Berger, U., Langlois, I., Oehme, M., & Kallenborn, R. (2004). Comparison of Three Types of Mass Spectrometer for High-Performance Liquid Chromatography/Mass Spectrometry Analysis of Perfluoroalkylated Substances and Fluorotelomer Alcohols. European Journal of Mass Spectrometry. https://doi.org/10.1255/ejms.679
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.