A Haemodynamic Brain–Computer Interface Based on Real-Time Classification of near Infrared Spectroscopy Signals during Motor Imagery and Mental Arithmetic
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Over the past decade, an increasing number of studies have investigated near infrared (NIR) spectroscopy for signal acquisition in brain–computer interface (BCI) systems. However, although a BCI relies on classifying brain signals in real-time, the majority of previous studies did not perform real-time NIR spectroscopy signal classification but derived knowledge about the feasibility of NIR spectroscopy for BCI purposes from offline analyses. The present study investigates whether NIR spectroscopy signals evoked by two different mental tasks (i.e. motor imagery and mental arithmetic) can be classified in real-time in order to control a NIR-BCI application. Furthermore, since this is the first study that attempts to distinguish between the haemodynamic responses to these two tasks, we aimed to investigate whether this task-combination is feasible for controlling a NIR-BCI. Twelve healthy participants were asked to control a moving ball on a computer screen by performing motor imagery and mental arithmetic tasks. The real-time classification of their task-specific NIR spectroscopy signals yielded accuracy rates ranging from 45% up to 93%. Offline analyses across all participants showed that both tasks evoked different haemodynamic responses in prefrontal and sensorimotor cortex areas. On the one hand, these results demonstrate the considerable potential of NIR spectroscopy for BCI signal acquisition and the feasibility of the applied mental tasks for NIR-BCI control. On the other hand, since the classification accuracy showed an unsatisfactory stability across measurement sessions, we conclude that further investigations and progress in methodological issues are needed and we discuss further steps that have to be taken until it is conceivable to implement a real-time capable NIR-BCI that works with sufficient accuracy across a large group of individuals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Procedures for Detecting Outlying Observations in Samples
Grubbs, F. E. (1969) · Technometrics · doi:10.1080/00401706.1969.10490657 · Cited by 4,105
Fox, P. T., & Raichle, M. E. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.4.1140 · Cited by 2,056
Motor imagery and direct brain-computer communication
Pfurtscheller, G., & Neuper, C. (2001) · Proceedings of the IEEE · doi:10.1109/5.939829 · Cited by 1,990
Self-citationBreaking the silence: Brain-computer interfaces (BCI) for communication and motor control
Birbaumer, N. (2006) · Psychophysiology · doi:10.1111/j.1469-8986.2006.00456.x · Cited by 722
Neurophysiological predictor of SMR-based BCI performance
Blankertz, B., Sannelli, C., Halder, S., Hammer, E. M., Kübler, A., Müller, K.-R., Curio, G., & Dickhaus, T. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.022 · Cited by 674
Do imagined and executed actions share the same neural substrate?
Decety, J. (1996) · Cognitive Brain Research · doi:10.1016/0926-6410(95)00033-x · Cited by 643
Cited by
fNIRS-based brain-computer interfaces: a review
Naseer, N., & Hong, K.-S. (2015) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2015.00003 · Cited by 988
“…al., 2015), signal variance (Tai and Chau, 2009; Holper and Wolf, 2011), amplitude (Naito et al., 2007; Cui et al., 2010b; Bauernfeind et al., 2011; Stangl et al., 2013), skewness (Tai and Chau, 2009; Holper and Wolf, 2011), kurtosis (Tai and Chau, 2009; Holper and Wolf, 2011), and zero crossing…”
BackgroundInfluentialMental stress assessment using simultaneous measurement of EEG and fNIRS
Al-Shargie, F., Kiguchi, M., Badruddin, N., Dass, S. C., Hani, A. F. M., & Tang, T. B. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.003882 · Cited by 284
Feature Extraction and Classification Methods for Hybrid fNIRS-EEG Brain-Computer Interfaces
Hong, K.-S., Khan, M. J., & Hong, M. J. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00246 · Cited by 283
Decoding of four movement directions using hybrid NIRS-EEG brain-computer interface
Khan, M. J., Hong, M. J., & Hong, K.-S. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00244 · Cited by 280
Hong, K.-S., & Khan, M. J. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00035 · Cited by 267
Kohl, S. H., Mehler, D. M. A., Lührs, M., Thibault, R. T., Konrad, K., & Sorger, B. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00594 · Cited by 161
“However, a recent study (Klein and Kranczioch, 2019) demonstrated that HbR is also affected by a global signal component.”
BackgroundInfluential
Metadata
- Authors
- Stangl, M., Bauernfeind, G., Kurzmann, J., Scherer, R., & Neuper, C.
- Venue
- Journal of Near Infrared Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2013-01-01
- Volume
- 21
- Issue
- 3
- Pages
- 157-171
- ISSN
- 0967-0335 (ISSN-L)
- 1751-6552
- OpenAlex
- W2316791108
- Cited by
- 50
- References
- 6
- FWCI
- 2.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.