An intelligent emergency response system: preliminary development and testing of automated fall detection
The DOI matches its Crossref record.
Abstract
We have designed an intelligent emergency response system to detect falls in the home. It uses image-based sensors. A pilot study was conducted using 21 subjects to evaluate the efficacy and performance of the fall-detection component of the system. Trials were conducted in a mock-up bedroom setting, with a bed, a chair and other typical bedroom furnishings. A small digital videocamera was installed in the ceiling at a height of approximately 2.6 m. The digital camera covered an area of approximately 5.0 m × 3.8 m. The subjects were asked to assume a series of postures, namely walking/standing, sitting/lying down in an inactive zone, stooping, lying down in a 'stretched' position, and lying down in a 'tucked' position. These five scenarios were repeated three times by each subject in a random order. These test positions totalled 315 tasks with 126 fall-simulated tasks and 189 non-fall-simulated tasks. The system detected a fall on 77% of occasions and missed a fall on 23%. False alarms occurred on only 5% of occasions. The results encourage the potential use of a vision-based system to provide safety and security in the homes of the elderly.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Challenges, issues and trends in fall detection systems
Igual, R., Medrano, C., & Plaza, I. (2013) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-12-66 · Cited by 654
Fall detection - Principles and Methods
Noury, N., Fleury, A., Rumeau, P., Bourke, A. K., Laighin, G. O., Rialle, V., & Lundy, J. E. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4352627 · Cited by 615
Fall Detection in Homes of Older Adults Using the Microsoft Kinect
Stone, E. E., & Skubic, M. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2312180 · Cited by 528
Robust Video Surveillance for Fall Detection Based on Human Shape Deformation
Rougier, C., Meunier, J., St-Arnaud, A., & Rousseau, J. (2011) · IEEE Transactions on Circuits and Systems for Video Technology · doi:10.1109/tcsvt.2011.2129370 · Cited by 490
Zigel, Y., Litvak, D., & Gannot*, I. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2030171 · Cited by 375
Bharucha, A. J., Anand, V., Forlizzi, J., Dew, M. A., Reynolds, C. F., Stevens, S., & Wactlar, H. (2009) · The American Journal of Geriatric Psychiatry · doi:10.1097/jgp.0b013e318187dde5 · Cited by 350
Approaches and principles of fall detection for elderly and patient
Yu, X. (2008) · HealthCom 2008 - 10th International Conference on e-health Networking, Applications and Services · doi:10.1109/health.2008.4600107 · Cited by 328
Fall Detection from Human Shape and Motion History Using Video Surveillance
Rougier, C., Meunier, J., St-Arnaud, A., & Rousseau, J. (2007) · 21st International Conference on Advanced Information Networking and Applications Workshops (AINAW'07) · doi:10.1109/ainaw.2007.181 · Cited by 324
iFall: An android application for fall monitoring and response
Sposaro, F., & Tyson, G. (2009) · 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2009.5334912 · Cited by 317
Yu, M., Rhuma, A., Naqvi, S. M., Wang, L., & Chambers, J. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2012.2214786 · Cited by 316
A proposal for the classification and evaluation of fall detectors
Noury, N., Rumeau, P., Bourke, A. K., ÓLaighin, G., & Lundy, J. E. (2008) · IRBM · doi:10.1016/j.irbm.2008.08.002 · Cited by 285
Vision-Based Fall Detection with Convolutional Neural Networks
Núñez-Marcos, A., Azkune, G., & Arganda-Carreras, I. (2017) · Wireless Communications and Mobile Computing · doi:10.1155/2017/9474806 · Cited by 282
“The use of tracking systems is also very extended; for example, Lee and Mihailidis [18] applied tracking techniques in a close environment to detect falls.”
MethodAuvinet, E., Multon, F., Saint-Arnaud, A., Rousseau, J., & Meunier, J. (2011) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2087385 · Cited by 256
Towards pervasive computing in health care – A literature review
Orwat, C., Graefe, A., & Faulwasser, T. (2008) · BMC Medical Informatics and Decision Making · doi:10.1186/1472-6947-8-26 · Cited by 232
A Wearable Airbag to Prevent Fall Injuries
Tamura, T., Yoshimura, T., Sekine, M., Uchida, M., & Tanaka, O. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2033673 · Cited by 223
Fall Detection Devices and Their Use With Older Adults: A Systematic Review
Chaudhuri, S., Thompson, H., & Demiris, G. (2014) · Journal of Geriatric Physical Therapy · doi:10.1519/jpt.0b013e3182abe779 · Cited by 215
iWander: An Android application for dementia patients
Sposaro, F., Danielson, J., & Tyson, G. (2010) · 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology · doi:10.1109/iembs.2010.5627669 · Cited by 178
Monocular 3D Head Tracking to Detect Falls of Elderly People
Rougier, C., Meunier, J., St-Arnaud, A., & Rousseau, J. (2006) · 2006 International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2006.260829 · Cited by 172
“For instance, Lee and Mihailidis [11] detect a fall using the shape of the person’s silhouette, and Nait-Charif and McKenna [12] detect inactivity outside the normal zones of inactivity like chairs or sofas.”
MethodAmbient Sensors for Elderly Care and Independent Living: A Survey
Uddin, M. Z., Khaksar, W., & Torresen, J. (2018) · Sensors · doi:10.3390/s18072027 · Cited by 166
“Lee & Chung [74] (2012) Fall detection Kinect depth camera with a laptop was installed to record a total 175 videos of different fall scenarios in indoor environments.”
BackgroundEdge Video Analytics for Public Safety: A Review
Zhang, Q., Sun, H., Wu, X., & Zhong, H. (2019) · Proceedings of the IEEE · doi:10.1109/jproc.2019.2925910 · Cited by 156
“[125] T.”
BackgroundVideo based technology for ambient assisted living: A review of the literature
Cardinaux, F., Bhowmik, D., Abhayaratne, C., & Hawley, M. S. (2011) · Journal of Ambient Intelligence and Smart Environments · doi:10.3233/ais-2011-0110 · Cited by 98
Rudzicz, F., Wang, R., Begum, M., & Mihailidis, A. (2015) · ACM Transactions on Accessible Computing · doi:10.1145/2744206 · Cited by 83
Self-citationDevelopment of an automated speech recognition interface for personal emergency response systems
Hamill, M., Young, V., Boger, J., & Mihailidis, A. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-26 · Cited by 74
Self-citationYoung, V., Rochon, E., & Mihailidis, A. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0207-9 · Cited by 9
“This system is further described by [1 – 4].”
MethodSelf-citation
Metadata
- Authors
- Lee, T., & Mihailidis, A.
- Venue
- Journal of Telemedicine and Telecare
- Publisher
- SAGE Publications
- Published
- 2005-06-01
- Volume
- 11
- Issue
- 4
- Pages
- 194-198
- ISSN
- 1357-633X (ISSN-L)
- 1758-1109
- OpenAlex
- W2091566335
- Cited by
- 237
- References
- 0
- FWCI
- 9.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.