Computerized transverse axial scanning (tomography): Part 1. Description of system
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This article describes a technique in which X-ray transmission readings are taken through the head at a multitude of angles: from these data, absorption values of the material contained within the head are calculated on a computer and presented as a series of pictures of slices of the cranium. The system is approximately 100 times more sensitive than conventional X-ray systems to such an extent that variations in soft tissues of nearly similar density can be displayed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computerized transverse axial scanning (tomography): Part 2. Clinical application*
Ambrose, J. (1973) · The British Journal of Radiology · doi:10.1259/0007-1285-46-552-1023 · Cited by 840
Proceedings of the British Society of Neuroradiologists
(1973) · The British Journal of Radiology · doi:10.1259/0007-1285-46-545-401 · Cited by 188
Cited by
Items 101–130 of 130
Plant Tissues in 3D via X-Ray Tomography: Simple Contrasting Methods Allow High Resolution Imaging
Staedler, Y. M., Masson, D., & Schönenberger, J. (2013) · PLoS ONE · doi:10.1371/journal.pone.0075295 · Cited by 182
The ventricular-brain ratio using planimetric measurement of EMI scans
Synek, V., & Reuben, J. R. (1976) · The British Journal of Radiology · doi:10.1259/0007-1285-49-579-233 · Cited by 182
Simaan, N., Yasin, R. M., & Wang, L. (2018) · Annual Review of Control, Robotics, and Autonomous Systems · doi:10.1146/annurev-control-060117-104956 · Cited by 182
Imaging of Neurotransmitter Receptors in the Living Human Brain
Sedvall, G. (1986) · Archives of General Psychiatry · doi:10.1001/archpsyc.1986.01800100089012 · Cited by 179
Imaging modalities to diagnose carotid artery stenosis: progress and prospect
Saxena, A., Ng, E. Y. K., & Lim, S. T. (2019) · BioMedical Engineering OnLine · doi:10.1186/s12938-019-0685-7 · Cited by 177
A General Local Reconstruction Approach Based on a Truncated Hilbert Transform
Ye, Y., Yu, H., Wei, Y., & Wang, G. (2007) · International Journal of Biomedical Imaging · doi:10.1155/2007/63634 · Cited by 176
“Since its introduction in 1973 [1], X-ray CT has revolutionized radiography and become a cornerstone of all the modern hospitals and clinics.”
BackgroundReview of functional/anatomical imaging in oncology
Histed, S. N., Lindenberg, M. L., Mena, E., Turkbey, B., Choyke, P. L., & Kurdziel, K. A. (2012) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e32834ec8a5 · Cited by 175
Flückiger, R., Marone, F., Stampanoni, M., Wokaun, A., & Büchi, F. N. (2011) · Electrochimica Acta · doi:10.1016/j.electacta.2010.12.016 · Cited by 173
Survival Data for 648 Patients with Osteosarcoma Treated at One Institution
Mankin, H. J., Hornicek, F. J., Rosenberg, A. E., Harmon, D. C., & Gebhardt, M. C. (2004) · Clinical Orthopaedics and Related Research · doi:10.1097/01.blo.0000145991.65770.e6 · Cited by 173
X-Ray Luminescence Computed Tomography via Selective Excitation: A Feasibility Study
Pratx, G., Carpenter, C. M., Sun, C., & Xing, L. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2055883 · Cited by 170
“In the proposed XLCT system, a scanning X-ray source and detector are mounted on opposite sides of the sample, in a way comparable to the first X-ray CT scanner [18].”
MethodKrause, M., Hausherr, J. M., Burgeth, B., Herrmann, C., & Krenkel, W. (2010) · Journal of Materials Science · doi:10.1007/s10853-009-4016-4 · Cited by 169
“Initially, CT has been developed as a tool for medical applications [25, 26 ].”
MethodA framework for computational anatomy
Thompson, P. M., & Toga, A. W. (2002) · Computing and Visualization in Science · doi:10.1007/s00791-002-0084-6 · Cited by 169
Advances in functional X-ray imaging techniques and contrast agents
Chen, H., Rogalski, M. M., & Anker, J. N. (2012) · Physical Chemistry Chemical Physics · doi:10.1039/c2cp41858d · Cited by 168
Muscle analysis using pQCT, DXA and MRI
Erlandson, M. C., Lorbergs, A. L., Mathur, S., & Cheung, A. M. (2016) · European Journal of Radiology · doi:10.1016/j.ejrad.2016.03.001 · Cited by 166
New Applications of Cardiac Computed Tomography
Danad, I., Fayad, Z. A., Willemink, M. J., & Min, J. K. (2015) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2015.03.005 · Cited by 166
The biomedical imaging resource at Mayo Clinic
Robb, R. A. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.952724 · Cited by 165
“The early 1970's also marked the advent of medical computer assisted tomography when the first CT scanner for head imaging was announced [ 3 ].”
Comparison of Different Body Size Parameters for Individual Dose Adaptation in Body CT of Adults
Menke, J. (2005) · Radiology · doi:10.1148/radiol.2362041327 · Cited by 164
Strong-field ionization with two-color circularly polarized laser fields
Mancuso, C. A., Hickstein, D. D., Grychtol, P., Knut, R., Kfir, O., Tong, X.-M., Dollar, F., Zusin, D., Gopalakrishnan, M., Gentry, C., et al. (2015) · Physical Review A · doi:10.1103/physreva.91.031402 · Cited by 164
Brain imaging: Applications in psychiatry
Swayze, V. W., Yates, W., & Andreasen, N. C. (1987) · Behavioral Sciences & the Law · doi:10.1002/bsl.2370050303 · Cited by 163
Mandibular morphology and diet in the genusCebus
Daegling, D. J. (1992) · International Journal of Primatology · doi:10.1007/bf02547832 · Cited by 162
“The major technological breakthrough of CT is that plane structures (i.e., mandibular cross sections) can be visualized without the interference of structures to either side of the section ( Hounsfield, 1973 ).”
BackgroundComputerised Tomography in Schizophrenia 15 Years On
Lewis, S. W. (1990) · British Journal of Psychiatry · doi:10.1192/s0007125000291824 · Cited by 161
Chiumello, D., Marino, A., Brioni, M., Cigada, I., Menga, F., Colombo, A., Crimella, F., Algieri, I., Cressoni, M., Carlesso, E., et al. (2016) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201507-1413oc · Cited by 161
The Edwin Smith papyrus: a clinical reappraisal of the oldest known document on spinal injuries
van Middendorp, J. J., Sanchez, G. M., & Burridge, A. L. (2010) · European Spine Journal · doi:10.1007/s00586-010-1523-6 · Cited by 160
“With the breakthroughs in medical imaging by Roentgen in 1895 (X-rays) and Hounsfield and Cormack in 1971 (computed tomography) physicians became able to estimate the severity of closed spinal column injuries [ 33 , 34].”
BackgroundBasics of iterative reconstruction methods in computed tomography: A vendor-independent overview
Stiller, W. (2018) · European Journal of Radiology · doi:10.1016/j.ejrad.2018.10.025 · Cited by 160
PRESENILE DEMENTIA: THE DIFFICULTIES OF EARLY DIAGNOSIS
Nott, P. N., & Fleminger, J. J. (1975) · Acta Psychiatrica Scandinavica · doi:10.1111/j.1600-0447.1975.tb00006.x · Cited by 160
Yamada, Y., Jinzaki, M., Hosokawa, T., Tanami, Y., Sugiura, H., Abe, T., & Kuribayashi, S. (2012) · European Journal of Radiology · doi:10.1016/j.ejrad.2012.07.013 · Cited by 160
Multimodality imaging techniques
Martí‐Bonmatí, L., Sopena, R., Bartumeus, P., & Sopena, P. (2010) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.393 · Cited by 158
Braunwald, E. (2017) · Circulation Research · doi:10.1161/circresaha.117.311812 · Cited by 150
Risk of Brain Tumor Induction from Pediatric Head CT Procedures: A Systematic Literature Review
Sheppard, J. P., Nguyen, T., Alkhalid, Y., Beckett, J. S., Salamon, N., & Yang, I. (2018) · Brain Tumor Research and Treatment · doi:10.14791/btrt.2018.6.e4 · Cited by 90
Dual-energy CT of acute bowel ischemia
Obmann, M. M., Punjabi, G., Obmann, V. C., Boll, D. T., Heye, T., Benz, M. R., & Yeh, B. M. (2022) · Abdominal Radiology · doi:10.1007/s00261-021-03188-4 · Cited by 50
Metadata
- Authors
- Hounsfield, G. N.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 1973-12
- Volume
- 46
- Issue
- 552
- Pages
- 1016-1022
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W2123169298
- Cited by
- 3,924
- References
- 2
- FWCI
- 110.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.