Epoxy resin based tissue substitutes
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
A series of epoxy resin based tissue substitutes, simulating adipose tissue, bone, breast, lung, muscle and skin is described. Details of the physical radiation characteristics of the formulated systems are given, together with the manufacturing procedures. The versatility of the range of substitutes is discussed in terms of both investigated and projected applications in experimental radiation studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photon cross sections from 1 keV to 100 MeV for elements Z=1 to Z=100
Storm, L., & Israel, H. I. (1970) · Atomic Data and Nuclear Data Tables · doi:10.1016/s0092-640x(70)80017-1 · Cited by 1,539
American Journal of Roentgenology
Bell, D., Campos, A., & Deng, F. (2017) · Radiopaedia.org · doi:10.53347/rid-56407 · Cited by 806
Hubbell, J. H. (1969) · doi:10.6028/nbs.nsrds.29 · Cited by 598
An instrumented phantom system for analog computation of treatment plans.
Alderson, S. W., Lanzl, L. H., ROLLINS, M., & SPIRA, J. (1962) · PubMed · Cited by 190
The Elementary Composition of Human Cortical Bone
WOODARD, H. Q. (1962) · Health Physics · doi:10.1097/00004032-196210000-00005 · Cited by 114
Cited by
Absorbed Radiation Dose in Mammography
Richard Hammerstein, G., Miller, D. W., White, D. R., Ellen Masterson, M., Woodard, H. Q., & Laughlin, J. S. (1979) · Radiology · doi:10.1148/130.2.485 · Cited by 549
Self-citationDeriving Hounsfield units using grey levels in cone beam computed tomography
Mah, P., Reeves, T. E., & McDavid, W. D. (2010) · Dentomaxillofacial Radiology · doi:10.1259/dmfr/19603304 · Cited by 371
Kalender, W. A., Felsenberg, D., Genant, H. K., Fischer, M., Dequeker, J., & Reeve, J. (1995) · European Journal of Radiology · doi:10.1016/0720-048x(95)00631-y · Cited by 263
Materials used to simulate physical properties of human skin
Dąbrowska, A. K., Rotaru, G. ‐., Derler, S., Spano, F., Camenzind, M., Annaheim, S., Stämpfli, R., Schmid, M., & Rossi, R. M. (2016) · Skin Research and Technology · doi:10.1111/srt.12235 · Cited by 259
Tissue mimicking materials for imaging and therapy phantoms: a review
McGarry, C. K., Grattan, L. J., Ivory, A. M., Leek, F., Liney, G. P., Liu, Y., Miloro, P., Rai, R., Robinson, A., Shih, A. J., et al. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/abbd17 · Cited by 215
Metadata
- Authors
- White, D. R., Martin, R. J., & Darlison, R.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 1977-11
- Volume
- 50
- Issue
- 599
- Pages
- 814-821
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W2092705380
- Cited by
- 252
- References
- 5
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.