CoChat

Radiobiological assessment of permanent implants using tumour repopulation factors in the linear-quadratic model

Dale, R. G. · 1989 · The British Journal of Radiology
Cited by 159

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

By combining existing linear-quadratic equations relating to decaying-source therapy with an assumed tumour repopulation factor, it has been possible to devise a method for the radiobiological assessment of permanent implants. For calculation purposes there is a time after which an implant can no longer be considered effective in sterilizing tumour cells. This “effective” treatment time for a permanent implant can be approximately defined in terms of the radionuclide decay constant, the potential doubling time, the initial dose-rate and the value of α in the tumour α/β ratio. The analytical technique has been applied to a specific intercomparison of commonly encountered implants using 125I and l98Au, and suggests that, even in the most favourable cases, the former radionuclide offers few radiobiological advantages. Although not specifically discussed here, the method can also be applied to the assessment of various forms of biologically targeted radiotherapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1259/0007-1285-62-735-241

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 159

Metadata

Authors
Dale, R. G.
Venue
The British Journal of Radiology
Published
1989-03-01
Volume
62
Issue
735
Pages
241-244
ISSN
  • 0007-1285 (ISSN-L)
  • 1748-880X
OpenAlex
W2056402604
Cited by
159
References
4
FWCI
5.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Radiobiological assessment of permanent implants using tumour repopulation factors in the linear-quadratic model. https://app.cochat.ai/papers/10.1259/0007-1285-62-735-241
The paper
Dale, R. G. (1989). Radiobiological assessment of permanent implants using tumour repopulation factors in the linear-quadratic model. The British Journal of Radiology. https://doi.org/10.1259/0007-1285-62-735-241

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.