The DOI matches its Crossref record.
National reference doses for common radiographic, fluoroscopic and dental X-ray examinations in the UK
Abstract
The National Patient Dose Database (NPDD) is maintained by the Radiation Protection Division of the Health Protection Agency. The latest review of the database analysed the data collected from 316 hospitals over a 5-year period to the end of 2005. The information supplied amounted to a total of 23 000 entrance surface dose measurements and 57 000 dose-area product measurements for single radiographs, and 208 000 dose-area product measurements along with 187 000 fluoroscopy times for diagnostic examinations or interventional procedures. In addition, patient dose data for dental X-ray examinations were included for the first time in the series of 5-yearly reviews. This article presents a summary of a key output from the NPDD - national reference doses. These are based on the third quartile values of the dose distributions for 30 types of diagnostic X-ray examination and 8 types of interventional procedure on adults, and for 4 types of X-ray examination on children. The reference doses are approximately 16% lower than the corresponding values in the previous (2000) review, and are typically less than half the values of the original UK national reference doses that were derived from a survey in the mid-1980s. This commentary suggests that two of the national reference doses from the 2000 review be retained as diagnostic reference levels because the older sample size was larger than for the 2005 review. No clear evidence could be found for the use of digital imaging equipment having a significant effect on dose.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
U.S. Diagnostic Reference Levels and Achievable Doses for 10 Adult CT Examinations
Kanal, K. M., Butler, P. F., Sengupta, D., Bhargavan-Chatfield, M., Coombs, L. P., & Morin, R. L. (2017) · Radiology · doi:10.1148/radiol.2017161911 · Cited by 395
Updated Australian diagnostic reference levels for adult CT
Lee, K. L., Beveridge, T., Sanagou, M., & Thomas, P. (2020) · Journal of Medical Radiation Sciences · doi:10.1002/jmrs.372 · Cited by 75
Reducing Radiation, Revising Reference Levels
Miller, D. L., Vano, E., & Rehani, M. M. (2015) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2014.07.012 · Cited by 17
Varghese, B., Kandanga, I., Puthussery, P., Vijayan, D., Babu, S. P. H., Aneesh, M. K., Noufal, M., Binu, E. V., Babu, A. C., James, S. M., et al. (2018) · Indian Journal of Radiology and Imaging · doi:10.4103/ijri.ijri_394_17 · Cited by 12
Diagnostic Reference Levels of Radiographic and CT Examinations in Jordan: A Systematic Review
Alzyoud, K., Al-Murshedi, S., & England, A. (2024) · Health Physics · doi:10.1097/hp.0000000000001778 · Cited by 6
Metadata
- Authors
- HART, D., HILLIER, M. C., & WALL, B. F.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-01
- Volume
- 82
- Issue
- 973
- Pages
- 1-12
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W2134552636
- Cited by
- 208
- References
- 0
- FWCI
- 3.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: National reference doses for common radiographic, fluoroscopic and dental X-ray examinations in the UK. https://app.cochat.ai/papers/10.1259/bjr/12568539
- The paper
- HART, D., HILLIER, M. C., & WALL, B. F. (2009). National reference doses for common radiographic, fluoroscopic and dental X-ray examinations in the UK. The British Journal of Radiology. https://doi.org/10.1259/bjr/12568539
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.