National reference doses for common radiographic, fluoroscopic and dental X-ray examinations in the UK
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
The National Patient Dose Database (NPDD) is maintained by the Radiation Protection Division of the Health Protection Agency. The latest review of the database analysed the data collected from 316 hospitals over a 5-year period to the end of 2005. The information supplied amounted to a total of 23 000 entrance surface dose measurements and 57 000 dose-area product measurements for single radiographs, and 208 000 dose-area product measurements along with 187 000 fluoroscopy times for diagnostic examinations or interventional procedures. In addition, patient dose data for dental X-ray examinations were included for the first time in the series of 5-yearly reviews. This article presents a summary of a key output from the NPDD - national reference doses. These are based on the third quartile values of the dose distributions for 30 types of diagnostic X-ray examination and 8 types of interventional procedure on adults, and for 4 types of X-ray examination on children. The reference doses are approximately 16% lower than the corresponding values in the previous (2000) review, and are typically less than half the values of the original UK national reference doses that were derived from a survey in the mid-1980s. This commentary suggests that two of the national reference doses from the 2000 review be retained as diagnostic reference levels because the older sample size was larger than for the 2005 review. No clear evidence could be found for the use of digital imaging equipment having a significant effect on dose.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
National survey of doses from CT in the UK: 2003
Shrimpton, P. C., Hillier, M. C., Lewis, M. A., & Dunn, M. (2006) · The British Journal of Radiology · doi:10.1259/bjr/93277434 · Cited by 568 · cited 1×
“The latest review of the PREDICT database includes national reference doses for eight common types of CT examination and was performed for the year 2003 [8, 9].”
MethodSelf-citationDoses to Patients from Medical X-ray Examinations in the UK - 2000 Review
Hart, D., Hillier, M., & Wall, B. F. (2002) · OpenGrey (Institut de l'Information Scientifique et Technique) · Cited by 201
Self-citationRecommended Standards For The Routine Performance Testing of Diagnostic X-Ray Imaging Systems
Evans, S. (1998) · Journal of Radiological Protection · doi:10.1088/0952-4746/18/2/023 · Cited by 159
Hart, D. B., Mc, H., & Bf, W. (2007) · Europe PMC (PubMed Central) · Cited by 156
Self-citationShrimpton, P. C., Wall, B. F., Jones, D., Fisher, E. S., Hillier, M., Kendall, G. M., & Harrison, R. M. (1986) · Medical Entomology and Zoology · Cited by 154
Self-citationReference Values for Diagnostic Radiology: Application and Impact
Gray, J. E., Archer, B. R., Butler, P. F., Hobbs, B. B., Mettler, F. A., Pizzutiello, R. J., Schueler, B. A., Strauss, K. J., Suleiman, O. H., & Yaffe, M. J. (2005) · Radiology · doi:10.1148/radiol.2352020016 · Cited by 143 · cited 1×
“Date of setting DRLs 2004 [18] 2003 [19] 2000 [20] 1999 [21] 2002 [22] 2006 [23,24] 2005 [25] ADULT Radiograph ESD per radiograph (mGy) Abdomen AP 4 10 10 10 10 4.”
How to set up and apply reference levels in fluoroscopy at a national level
Aroua, A., Rickli, H., Stauffer, J., Schnyder, P. A., Trueb, P. R., Valley, J. ‐., Vock, P., & Verdun, F. R. (2006) · European Radiology · doi:10.1007/s00330-006-0463-3 · Cited by 95 · cited 1×
“Date of setting DRLs 2004 [18] 2003 [19] 2000 [20] 1999 [21] 2002 [22] 2006 [23,24] 2005 [25] ADULT Radiograph ESD per radiograph (mGy) Abdomen AP 4 10 10 10 10 4.”
Cited by
U.S. Diagnostic Reference Levels and Achievable Doses for 10 Adult CT Examinations
Kanal, K. M., Butler, P. F., Sengupta, D., Bhargavan-Chatfield, M., Coombs, L. P., & Morin, R. L. (2017) · Radiology · doi:10.1148/radiol.2017161911 · Cited by 395
Miller, D. L., Kwon, D., & Bonavia, G. H. (2009) · Radiology · doi:10.1148/radiol.2533090354 · Cited by 207
Updated Australian diagnostic reference levels for adult CT
Lee, K. L., Beveridge, T., Sanagou, M., & Thomas, P. (2020) · Journal of Medical Radiation Sciences · doi:10.1002/jmrs.372 · Cited by 75
“Improved optimisation has resulted in an overall lowering of doses with each iteration of the dose review.(8,15) In Australia, the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) is responsible for setting National DRLs (NDRLs) and conducts an ongoing national dosimetry survey of common MDCT protoc…”
BackgroundReducing Radiation, Revising Reference Levels
Miller, D. L., Vano, E., & Rehani, M. M. (2015) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2014.07.012 · Cited by 17
“The 2005 DRLs were approximately 16% lower than the corresponding 2000 values and were approximately half of the corresponding mid-1980s values [5].”
BackgroundMethodVarghese, B., Kandanga, I., Puthussery, P., Vijayan, D., Babu, S. P. H., Aneesh, M. K., Noufal, M., Binu, E. V., Babu, A. C., James, S. M., et al. (2018) · Indian Journal of Radiology and Imaging · doi:10.4103/ijri.ijri_394_17 · Cited by 12
“The practice of use of DRL has been shown to reduce the overall dose observed in clinical practice.[25] Furthermore, improvements in equipment dose efficiency might also have contributed in these dose reductions.”
Diagnostic Reference Levels of Radiographic and CT Examinations in Jordan: A Systematic Review
Alzyoud, K., Al-Murshedi, S., & England, A. (2024) · Health Physics · doi:10.1097/hp.0000000000001778 · Cited by 6
Alhorani, Q., Alkhybari, E., Rawashdeh, M., Sabarudin, A., Latiff, R. A., Al-Ibraheem, A., & Mohamad, M. (2024) · Journal of Radiological Protection · doi:10.1088/1361-6498/ad2c62 · Cited by 6
“The UK NDRL approach for diagnostic CT has been demonstrated to be a successful dose-reduction tool, with radiation levels decreasing by 16% between 2000 and 2005 and by 50% since its implementation in the 1980s [12].”
Metadata
- Authors
- HART, D., HILLIER, M. C., & WALL, B. F.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-01
- Volume
- 82
- Issue
- 973
- Pages
- 1-12
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W2134552636
- Cited by
- 208
- References
- 7
- FWCI
- 3.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.