The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
U.S. Diagnostic Reference Levels and Achievable Doses for 10 Adult CT Examinations
Abstract
Purpose To develop diagnostic reference levels (DRLs) and achievable doses (ADs) for the 10 most common adult computed tomographic (CT) examinations in the United States as a function of patient size by using the CT Dose Index Registry. Materials and Methods Data from the 10 most commonly performed adult CT head, neck, and body examinations from 583 facilities were analyzed. For head examinations, the lateral thickness was used as an indicator of patient size; for neck and body examinations, water-equivalent diameter was used. Data from 1 310 727 examinations (analyzed by using SAS 9.3) provided median values, as well as means and 25th and 75th (DRL) percentiles for volume CT dose index (CTDIvol), dose-length product (DLP), and size-specific dose estimate (SSDE). Applicable results were compared with DRLs from eight countries. Results More than 46% of the facilities were community hospitals; 13% were academic facilities. More than 48% were in metropolitan areas, 39% were suburban, and 13% were rural. More than 50% of the facilities performed fewer than 500 examinations per month. The abdomen and pelvis was the most frequently performed examination in the study (45%). For body examinations, DRLs (75th percentile) and ADs (median) for CTDIvol, SSDE, and DLP increased consistently with the patient’s size (water-equivalent diameter). The relationships between patient size and DRLs and ADs were not as strong for head and neck examinations. These results agree well with the data from other countries. Conclusion DRLs and ADs as a function of patient size were developed for the 10 most common adult CT examinations performed in the United States. © RSNA, 2017
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ICRP Publication 135: Diagnostic Reference Levels in Medical Imaging
Vañó, E., Miller, D. L., Martin, C. J., Rehani, M. M., Kang, K., Rosenstein, M., Ortiz-López, P., Mattsson, S., Padovani, R., & Rogers, A. (2017) · Annals of the ICRP · doi:10.1177/0146645317717209 · Cited by 1,043
NCRP report no. 93: Ionizing radiation exposure of the population of the United States
Eckelman, W. C. (1988) · International Journal of Radiation Applications and Instrumentation. Part B. Nuclear Medicine and Biology · doi:10.1016/0883-2897(88)90020-7 · Cited by 755
CT Dose Index and Patient Dose: They Are Not the Same Thing
McCollough, C. H., Leng, S., Yu, L., Cody, D. D., Boone, J. M., & McNitt-Gray, M. F. (2011) · Radiology · doi:10.1148/radiol.11101800 · Cited by 463
Radiological protection and safety in medicine
(1996) · Annals of the ICRP · doi:10.1016/s0146-6453(00)89195-2 · Cited by 438
McCollough, C. H., Bakalyar, D., Bostani, M., Brady, S. L., Boedeker, K., Boone, J. M., Chen‐Mayer, H. H., Christianson, O. I., Leng, S., Li, B., et al. (2014) · PubMed · Cited by 269
HART, D., HILLIER, M. C., & WALL, B. F. (2009) · The British Journal of Radiology · doi:10.1259/bjr/12568539 · Cited by 208
(1991) · Annals of the ICRP · doi:10.1016/0146-6453(91)90065-o · Cited by 189
Establishment of CT diagnostic reference levels in Ireland
Foley, S. J., McEntee, M. F., & Rainford, L. A. (2012) · The British Journal of Radiology · doi:10.1259/bjr/15839549 · Cited by 186
CT in the Emergency Department: A Real-Time Study of Changes in Physician Decision Making
Pandharipande, P. V., Reisner, A. T., Binder, W. D., Zaheer, A., Gunn, M. L. D., Linnau, K. F., Miller, C., Avery, L. L., Herring, M. S., Tramontano, A. C., et al. (2015) · Radiology · doi:10.1148/radiol.2015150473 · Cited by 151
Diagnostic Reference Ranges for Pediatric Abdominal CT
Goske, M. J., Strauss, K. J., Coombs, L. P., Mandel, K. E., Towbin, A. J., Larson, D. B., Callahan, M. J., Darge, K., Podberesky, D. J., Frush, D. P., et al. (2013) · Radiology · doi:10.1148/radiol.13120730 · Cited by 120
Self-citation
Cited by
Updated Australian diagnostic reference levels for adult CT
Lee, K. L., Beveridge, T., Sanagou, M., & Thomas, P. (2020) · Journal of Medical Radiation Sciences · doi:10.1002/jmrs.372 · Cited by 75
Bos, D., Yu, S., Luong, J., Chu, P., Wang, Y., Einstein, A. J., Starkey, J., Delman, B. N., Duong, P.-A. T., Das, M., et al. (2022) · European Radiology · doi:10.1007/s00330-021-08266-1 · Cited by 64
Kumsa, M. J., Nguse, T. M., Ambessa, H. B., Gele, T. T., Fantaye, W. G., & Dellie, S. T. (2023) · BMC Medical Imaging · doi:10.1186/s12880-023-00963-1 · Cited by 18
Sohrabi, M., Parsi, M., & Mianji, F. (2018) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncx252 · Cited by 18
Relationships of radiation dose indices with body size indices in adult body computed tomography
Inoue, Y., Itoh, H., Nagahara, K., Hata, H., & Mitsui, K. (2023) · Tomography · doi:10.3390/tomography9040110 · Cited by 16
Metadata
- Authors
- Kanal, K. M., Butler, P. F., Sengupta, D., Bhargavan-Chatfield, M., Coombs, L. P., & Morin, R. L.
- Venue
- Radiology
- Published
- 2017-07
- Volume
- 284
- Issue
- 1
- Pages
- 120-133
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2590236471
- Cited by
- 395
- References
- 18
- FWCI
- 21.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: U.S. Diagnostic Reference Levels and Achievable Doses for 10 Adult CT Examinations. https://app.cochat.ai/papers/10.1148/radiol.2017161911
- The paper
- Kanal, K. M., Butler, P. F., Sengupta, D., Bhargavan-Chatfield, M., Coombs, L. P., & Morin, R. L. (2017). U.S. Diagnostic Reference Levels and Achievable Doses for 10 Adult CT Examinations. Radiology. https://doi.org/10.1148/radiol.2017161911
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.