The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Jananese Society of Hypertension (JSH) Guidelines for Self-Monitoring of Blood Pressure at Home
Open accessAbstract
UNLABELLED: Home blood pressure (BP) measurements are indispensable for the improvement of hypertension management in medical practice as well as for the recognition of hypertension in the population. The Working Group for Establishment of Guidelines for Measurement Procedures of Self-Monitoring of Blood Pressure at Home of the Japanese Society of Hypertension has established standards for all techniques and procedures of home BP measurements. The recommendations are as follows. RECOMMENDATION: 1) Arm-cuff devices based on the cuff-oscillometric method that have been validated officially, and the accuracy of which has been confirmed in each individual, should be used for home BP measurement. 2) The BP should be measured at the upper arm. Finger-cuff devices and wrist-cuff devices should not be used for home BP measurements. 3) Devices for home BP measurement should be adapted to the American Association for Medical Instrumentation (AAMI) standards and the British Hypertension Society (BHS) guidelines. In addition, the difference between the BP measured by the auscultatory method and that measured using the device should be within 5 mmHg in each individual. The home measurement device should be validated before use, and at regular intervals during use. 4) Home BP should be monitored under the following conditions. The morning measurement should be made within 1 h after waking, after micturition, sitting after 1 to 2 min of rest, before drug ingestion, and before breakfast. The evening measurement should be made just before going to bed, sitting after 1 to 2 min of rest. 5) Home BP should be measured at least once in the morning and once in the evening. 6) All home BP measurements should be documented without selection, together with the date, time, and pulse rate. Use of devices with a printer or an integrated circuit memory is useful to avoid selection bias. 7) The home BP in the morning and that in the evening should be averaged separately for a certain period. The first measurement on each occasion should be used for totaling. 8) Home BP values averaged for a certain period indicate hypertension when 135/80 mmHg and over and definite hypertension when 135/85 mmHg and over. Normotension is defined as less than 125/80 mmHg and definite normotension as less than 125/75 mmHg. Home BP measurements based on these guidelines can be considered an appropriate tool for clinical decision-making, and it is hoped that these guidelines will serve to reduce confusion and confirm the place of home BP measurement in clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chobanian, A. V. (2003) · JAMA · doi:10.1001/jama.289.19.2560 · Cited by 25,386
(1997) · Archives of Internal Medicine · doi:10.1001/archinte.1997.00440420033005 · Cited by 3,777
(1999) · Journal of Hypertension · doi:10.1097/00004872-199917020-00001 · Cited by 3,695
(2003) · Journal of Hypertension · doi:10.1097/00004872-200306000-00001 · Cited by 3,027
Mancia, G., Rosei, E. A., Cífková, R., DeBacker, G., Erdine, S. E., Fagard, R., Farsang, C., Heagerty, A. M., Kawecka-Jaszcs, K., Kiowski, W., et al. (2003) · Lirias · doi:10.1097/01.hjh.0000059051.65882.32 · Cited by 2,601
Human blood pressure determination by sphygmomanometry.
Perloff, D., Grim, C., Flack, J., Frohlich, E. D., Hill, M., McDonald, M., & Morgenstern, B. Z. (1993) · Circulation · doi:10.1161/01.cir.88.5.2460 · Cited by 1,591
O??Brien, E., Petrie, J., Littler, W., de Swiet, M., Padfield, P. L., O??Malley, K., Jamieson, M., Altman, D., Bland, M., & Atkins, N. (1990) · Journal of Hypertension · doi:10.1097/00004872-199007000-00004 · Cited by 772
OʼBrien, E., Pickering, T., Asmar, R., Myers, M., Parati, G., Staessen, J., Mengden, T., Imai, Y., Waeber, B., Palatini, P., et al. (2002) · Blood Pressure Monitoring · doi:10.1097/00126097-200202000-00002 · Cited by 744
Self-citationOhkubo, T., Imai, Y., Tsuji, I., Nagai, K., Kato, J., Kikuchi, N., Nishiyama, A., Aihara, A., Sekino, M., Kikuya, M., et al. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816070-00010 · Cited by 741
Self-citationAmbulatory blood pressure normality: results from the PAMELA study
Mancia, G., Sega, R., Bravi, C., Vito, G. D., Valagussa, F., Cesana, G., & Zanchetti, A. (1995) · Journal of Hypertension · doi:10.1097/00004872-199512000-00003 · Cited by 547
Recommendations for the use of home (self) and ambulatory blood pressure monitoring
Pickering, T. (1996) · American Journal of Hypertension · doi:10.1016/0895-7061(95)00341-x · Cited by 472
Direct arterial pressure recording in unrestricted man.
Bevan, A. T., Honour, A. J., & Stott, F. H. (1969) · PubMed · Cited by 383
Ayman, D., & Goldshine, A. D. (1940) · The American Journal of the Medical Sciences · doi:10.1097/00000441-194010000-00005 · Cited by 293
"White coat" versus "sustained" borderline hypertension in Tecumseh, Michigan.
Julius, S., Mejia, A., Jones, K., Krause, L., Schork, N., van de Ven, C., Johnson, E., Petrin, J., Sekkarie, M. A., & Kjeldsen, S. E. (1990) · Hypertension · doi:10.1161/01.hyp.16.6.617 · Cited by 272
Reliability of reporting self-measured blood pressure values by hypertensive patients
MENGDEN, T., HERNANDEZMEDINA, R., BELTRAN, B., ALVAREZ, E., KRAFT, K., & VETTER, H. (1998) · American Journal of Hypertension · doi:10.1016/s0895-7061(98)00241-6 · Cited by 268
Mauck, G. W., Smith, C. R., Geddes, L. A., & Bourland, J. D. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138195 · Cited by 222
(1991) · Medical Entomology and Zoology · Cited by 215
Asmar, R., & Zanchetti, A. (2000) · Journal of Hypertension · doi:10.1097/00004872-200018050-00001 · Cited by 213
Self-monitoring of blood pressure at home: how many measurements are needed?
Stergiou, G. S., Skeva, I. I., Zourbaki, A. S., & Mountokalakis, T. D. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816060-00002 · Cited by 212
Riva-Rocci, S. (1896) · Medical Entomology and Zoology · Cited by 192
Ambulatory blood pressure of adults in Ohasama, Japan.
Imai, Y., Nagai, K., Sakuma, M., Sakuma, H., Nakatsuka, H., Satoh, H., Minami, N., Munakata, M., Hashimoto, J., & Yamagishi, T. (1993) · Hypertension · doi:10.1161/01.hyp.22.6.900 · Cited by 181
Self-citationImai, Y., Satoh, H., Nagai, K., Sakuma, M., Sakuma, H., Minami, N., Munakata, M., Hashimoto, J., Yamagishi, T., Watanabe, N., et al. (1993) · Journal of Hypertension · doi:10.1097/00004872-199312000-00017 · Cited by 173
Self-citationImai, Y., Abe, K., Sasaki, S., Minami, N., Munakata, M., Sakuma, H., Hashimoto, J., Sekino, H., Imai, K., & Yoshinaga, K. (1989) · Journal of Hypertension · doi:10.1097/00004872-198912000-00009 · Cited by 123
Self-citationGuidelines for the Management of Hypertension for General Practitioners.
Japanese Society of Hypertension Gu (2001) · Hypertension Research · doi:10.1291/hypres.24.613 · Cited by 120
Characteristics of blood pressure measured at home in the morning and in the evening
Imai, Y., Nishiyama, A., Sekino, M., Aihara, A., Kikuya, M., Ohkubo, T., Matsubara, M., Hozawa, A., Tsuji, I., Ito, S., et al. (1999) · Journal of Hypertension · doi:10.1097/00004872-199917070-00004 · Cited by 110
Self-citationImai, Y., Ohkubo, T., Hozawa, A., Tsuji, I., Matsubara, M., Araki, T., Chonan, K., Kikuya, M., Satoh, H., Hisamichi, S., et al. (2001) · Journal of Hypertension · doi:10.1097/00004872-200102000-00003 · Cited by 102
Self-citationHome blood pressure: variability, comparison with office readings and proposal for reference values
de Gaudemaris, R., Nguyen, C. P., & Mallion, J. (1994) · Journal of Hypertension · doi:10.1097/00004872-199407000-00016 · Cited by 98
(1969) · PubMed · Cited by 96
Device for the self-measurement of blood pressure that can monitor blood pressure during sleep
Chonan, K., Kikuya, M., Araki, T., Fujiwara, T., Suzuki, M., Michimata, M., Hashimoto, J., Ohkubo, T., Hozawa, A., Yamamoto, N., et al. (2001) · Blood Pressure Monitoring · doi:10.1097/00126097-200108000-00008 · Cited by 95
Self-citationAccuracy and reliability of wrist-cuff devices for self-measurement of blood pressure
Kikuya, M., Chonan, K., Imai, Y., Gotō, E., & Ishii, M. (2002) · Journal of Hypertension · doi:10.1097/00004872-200204000-00019 · Cited by 92
Self-citationThijs, L., Staessen, J. A., Celis, H., Fagard, R., Cort, P. D., de Gaudemaris, R., Enström, I., lmai, Y., Julius, S., Ménard, J., et al. (1999) · Blood Pressure Monitoring · doi:10.1097/00126097-199902000-00004 · Cited by 67
Mengden, T., Chamontin, B., Chau, N. P., Gámiz, J. L. P., & Chanudet, X. (2000) · PubMed · Cited by 60
Shirasaki, O., Terada, H., Niwano, K., Nakanishi, T., Kanai, M., Miyawaki, Y., Souma, T., Tanaka, T., & Kusunoki, T. (2001) · Blood Pressure Monitoring · doi:10.1097/00126097-200112000-00007 · Cited by 59
Self-measurement of blood pressure at home to evaluate drug effects by the trough
M??nard, J., Châtellier, G., Day, M., & Vaur, L. (1994) · Journal of Hypertension · doi:10.1097/00004872-199412001-00005 · Cited by 58
Fujiwara, T., Nishimura, T., Ohkuko, T., & Imai, Y. (2002) · Blood Pressure Monitoring · doi:10.1097/00126097-200202000-00016 · Cited by 58
Self-citationAmerican College of Physicians (1993) · Annals of Internal Medicine · doi:10.7326/0003-4819-118-11-199306010-00010 · Cited by 58
Imai, Y., Hozawa, A., Ohkubo, T., Tsuji, I., Yamaguchi, J., Matsubara, M., Michimata, M., Hashimoto, J., Fujiwara, T., Nagai, K., et al. (2001) · Blood Pressure Monitoring · doi:10.1097/00126097-200112000-00013 · Cited by 42
Self-citationAmerican national standard for nonautomated sphygmomanometers summary report
Prisant, L. M., Alpert, B. S., Robbins, C., et al. (1995) · American Journal of Hypertension · doi:10.1016/0895-7061(94)00175-b · Cited by 38
Staessen, J. A., Celis, H., Hond, E. D., Giot, C., Leeman, M., O'Brien, E. T., Vandenhoven, G., & Fagard, R. H. (2002) · Blood Pressure Monitoring · doi:10.1097/00126097-200202000-00012 · Cited by 23
Cited by
The Japanese Society of Hypertension Guidelines for the Management of Hypertension (JSH 2019)
Umemura, S., Arima, H., Arima, S., Asayama, K., Dohi, Y., Hirooka, Y., Horio, T., Hoshide, S., Ikeda, S., Ishimitsu, T., et al. (2019) · Hypertension Research · doi:10.1038/s41440-019-0284-9 · Cited by 1,880
Self-citationAssessment and management of blood-pressure variability
Parati, G., Ochoa, J. E., Lombardi, C., & Bilo, G. (2013) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2013.1 · Cited by 853
Parati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837
Self-citationPickering, T. G., Miller, N. H., Ogedegbe, G., Krakoff, L. R., Artinian, N. T., & Goff, D. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.189010 · Cited by 668
Does monitoring goal progress promote goal attainment? A meta-analysis of the experimental evidence.
Harkin, B., Webb, T. L., Chang, B. P. I., Prestwich, A., Conner, M., Kellar, I., Benn, Y., & Sheeran, P. (2016) · Psychological Bulletin · doi:10.1037/bul0000025 · Cited by 564
Metadata
- Authors
- IMAI, Y., OTSUKA, K., KAWANO, Y., SHIMADA, K., HAYASHI, H., TOCHIKUBO, O., MIYAKAWA, M., & FUKIYAMA, K.
- Venue
- Hypertension Research
- Publisher
- Japanese Society of Hypertension
- Published
- 2003
- Volume
- 26
- Issue
- 10
- Pages
- 771-782
- ISSN
- 0916-9636 (ISSN-L)
- 1348-4214
- OpenAlex
- W2105052825
- Cited by
- 309
- References
- 40
- FWCI
- 10.27
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.