CoChat

Control of Blood Pressure as Measured at Home and Office, and Comparison with Physicians' Assessment of Control among Treated Hypertensive Patients in Japan: First Report of the Japan Home versus Office Blood Pressure Measurement Evaluation (J-HOME) Study

Open access
OHKUBO, Takayoshi, OBARA, Taku, FUNAHASHI, Jin, KIKUYA, Masahiro, ASAYAMA, Kei, METOKI, Hirohito, OIKAWA, Takuya, TAKAHASHI, Hisaki, HASHIMOTO, Junichiro, TOTSUNE, Kazuhito, IMAI, Yutaka · 2004 · Hypertension Research
Cited by 127

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

The Japan Home versus Office Blood Pressure Measurement Evaluation (J-HOME) study was conducted to measure the control of blood pressure (BP) as evaluated by home BP measurement among 3,400 patients with essential hypertension (mean age: 66 years; females: 55%) receiving antihypertensive treatment in primary care settings in Japan. The purpose of this first report was to compare characteristics of BP control as measured at home and in the clinic (office) and define their association with BP control as evaluated by physicians. Mean systolic/diastolic BP (SBP/DBP) values were 140/82 mmHg for home BP and 143/81 mmHg for office BP. BP levels were not adequately controlled among approximately 60% of the patients, according to reference values described in the national guidelines (office BP: <140/90 mmHg; home BP: <135/85 mmHg). Even among patients evaluated by physicians as having excellent or fairly good BP control, office and home SBP values were insufficiently controlled in approximately 50%. Although the tendency was more remarkable among older patients, whose recommended target BP levels are higher than those of middle-aged patients in the Japanese Hypertension Society 2000 criteria, office and home BP values were not adequately controlled in approximately 50% of the middle-aged patients whose BP control was evaluated as good. Our findings suggest that an important reason why home and office BP values are not adequately controlled is that physicians approve relatively higher BP levels under treatment, even among middle-aged patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1291/hypres.27.755

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

Metadata

Authors
OHKUBO, T., OBARA, T., FUNAHASHI, J., KIKUYA, M., ASAYAMA, K., METOKI, H., OIKAWA, T., TAKAHASHI, H., HASHIMOTO, J., TOTSUNE, K., & IMAI, Y.
Venue
Hypertension Research
Published
2004
Volume
27
Issue
10
Pages
755-763
ISSN
  • 0916-9636 (ISSN-L)
  • 1348-4214
OpenAlex
W2006487233
Cited by
127
References
7
FWCI
5.99
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.