Vibration control of high-rise buildings for wind: a robust passive and active tuned mass damper
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Tuned mass dampers (TMDs) have been installed in many high-rise buildings, to improve their resiliency under dynamic loads. However, high-rise buildings may experience natural frequency changes under ambient temperature fluctuations, extreme wind loads and relative humidity variations. This makes the design of a TMD challenging and may lead to a detuned scenario, which can reduce significantly the performance. To alleviate this problem, the current paper presents a proposed approach for the design of a robust and efficient TMD. The approach accounts for the uncertain natural frequency, the optimization objective and the input excitation. The study shows that robust design parameters can be different from the optimal parameters. Nevertheless, predetermined optimal parameters are useful to attain design robustness. A case study of a high-rise building is executed. The TMD designed with the proposed approach showed its robustness and effectiveness in reducing the responses of high-rise buildings under multidirectional wind. The case study represents an engineered design that is instructive. The results show that shear buildings may be controlled with less effort than cantilever buildings. Structural control performance in high-rise buildings may depend on the shape of the building, hence the flow patterns, as well as the wind direction angle. To further increase the performance of the robust TMD in one lateral direction, active control using LQG and fuzzy logic controllers was carried out. The performance of the controllers is remarkable in enhancing the response reduction. In addition, the fuzzy logic controller may be more robust than the LQG controller.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Long term vibration monitoring of an RC slab: Temperature and humidity effect
Xia, Y., Hao, H., Zanardo, G., & Deeks, A. (2006) · Engineering Structures · doi:10.1016/j.engstruct.2005.09.001 · Cited by 331
Aly, A. M. (2014) · The Structural Design of Tall and Special Buildings · doi:10.1002/tal.1068 · Cited by 74
Self-citation
Research works printed but not linked: 32
- 2001, Eng. Struct., 23, 1512, 10.1016/S0141-0296(01)00037-2 · DOI
- 10.1155/2012/251543 · DOI
- 10.1002/tal.647 · DOI
- 10.1155/2011/549621 · DOI
- 10.1061/41016(314)285 · DOI
- 2007, Struct. Control. Health Monit., 14, 83, 10.1002/stc.85 · DOI · Paper page
- 1997, J. Microcomput. Civ. Eng., 12, 205, 10.1111/0885-9507.00057 · DOI
- 2006, Bull Seismol. Soc. Amer., 96, 237, 10.1785/0120050052 · DOI · Paper page
- 1966, IEEE T. Automat. Contr., 11, 93, 10.1109/TAC.1966.1098264 · DOI · Paper page
- 2003, J. Struct. Eng., 129, 857, 10.1061/(ASCE)0733-9445(2003)129:7(857) · doi:10.1061/(asce)0733-9445(2003)129:7(857 · Paper page
- 1995, J. Eng. Mech., 121, 1082, 10.1061/(ASCE)0733-9399(1995)121:10(1082) · doi:10.1061/(asce)0733-9399(1995)121:10(1082 · Paper page
- 10.1002/tal.421 · DOI · Paper page
- 2002, J. Wind Eng. Ind. Aerod., 90, 1919, 10.1016/S0167-6105(02)00298-2 · DOI
- 2006, Eng. Struct., 28, 912, 10.1016/j.engstruct.2005.10.017 · DOI
- 2010, Mech. Syst. Signal Pr., 24, 746, 10.1016/j.ymssp.2009.09.011 · DOI
- 2006, J. Sound Vib., 298, 280, 10.1016/j.jsv.2006.05.018 · DOI
- 2002, Struct. Des. Tall Spec., 11, 129
- 2007, J. Struct. Eng., 133, 1742, 10.1061/(ASCE)0733-9445(2007)133:12(1742) · doi:10.1061/(asce)0733-9445(2007)133:12(1742 · Paper page
- 10.1016/S0167-6105(02)00431-2 · DOI
- 10.1002/tal.1027 · DOI
- 2006, Alex. Eng. J., 45, 131
- 2012, J. Wind Eng. Ind. Aerod., 107-108, 118, 10.1016/j.jweia.2012.03.034 · DOI
- 2003, J. Struct. Eng., 129, 470, 10.1061/(ASCE)0733-9445(2003)129:4(470) · doi:10.1061/(asce)0733-9445(2003)129:4(470 · Paper page
- 2004, J. Eng. Mech., 130, 492, 10.1061/(ASCE)0733-9399(2004)130:4(492) · doi:10.1061/(asce)0733-9399(2004)130:4(492
- 2007, Struct. Des. Tall Spec., 16, 501, 10.1002/tal.413 · DOI · Paper page
- 1999, Earthq. Eng. Struct. D., 28, 879, 10.1002/(SICI)1096-9845(199908)28:8<879::AID-EQE845>3.0.CO;2-V · DOI · Paper page
- 1998, Earthq. Eng. Struct. D., 27, 1127, 10.1002/(SICI)1096-9845(1998110)27:11<1127::AID-EQE774>3.0.CO;2-F · DOI · Paper page
- 1980, Earthq. Eng. Struct. D., 8, 197, 10.1002/eqe.4290080302 · DOI · Paper page
- 1998, Eng. Struct., 20, 222, 10.1016/S0141-0296(97)00081-3 · DOI
- 2004, J. Eng. Mech., 130, 437, 10.1061/(ASCE)0733-9399(2004)130:4(437) · doi:10.1061/(asce)0733-9399(2004)130:4(437 · Paper page
- 2010, Eng. Struct., 32, 2379, 10.1016/j.engstruct.2010.04.012 · DOI · Paper page
- 2010, Earthq. Eng. Eng. Vib., 9, 295, 10.1007/s11803-010-0014-4 · DOI
Cited by
Research developments in vibration control of structures using passive tuned mass dampers
Elias, S., & Matsagar, V. (2017) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2017.09.015 · Cited by 556
Application of Tuned Mass Dampers for Structural Vibration Control: A State-of-the-art Review
Rahimi, F., Aghayari, R., & Samali, B. (2020) · Civil Engineering Journal · doi:10.28991/cej-2020-03091571 · Cited by 138
“Since then, they have been installed in a number of high-rise buildings [18].”
BackgroundCompliant liquid column damper modified by shape memory alloy device for seismic vibration control
Gur, S., Mishra, S. K., Bhowmick, S., & Chakraborty, S. (2014) · Smart Materials and Structures · doi:10.1088/0964-1726/23/10/105009 · Cited by 30
Vibration Control in High-Rise Buildings for Multi-Hazard
Abburu, S. A. S. (2022) · doi:10.31390/gradschool_theses.1991 · Cited by 1
“…earthquake or wind excitation, one can obtain the uncontrolled displacement and acceleration response (without the TMD), then from Figure 6 according to the required reduction 17 in the displacement and/or the acceleration response, the required mass ratio of the TMD can be estimated (Aly, 2014).”
BackgroundMethodInfluential
Metadata
- Authors
- Aly, A. M.
- Venue
- Smart Structures and Systems
- Publisher
- Techno-Press
- Published
- 2014-03-25
- Volume
- 13
- Issue
- 3
- Pages
- 473-500
- ISSN
- 1738-1584 (ISSN-L)
- OpenAlex
- W2048879479
- Cited by
- 58
- References
- 2
- FWCI
- 8.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.