IN VITRO HUMAN MONOCYTE RESPONSE TO WEAR PARTICLES OF TITANIUM ALLOY CONTAINING VANADIUM OR NIOBIUM
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Our aim was to determine whether in vitro studies would detect differences in the cellular response to wear particles of two titanium alloys commonly used in the manufacture of joint replacement prostheses. Particles were of the order of 1 μm in diameter representative of those found adjacent to failed prostheses. Exposure of human monocytes to titanium 6-aluminium 4- vanadium (TiAlV) at concentrations of 4 x 10 7 particles/ml produced a mean prostaglandin E 2 release of 2627.6 pM; this was significantly higher than the 317.4 pM induced by titanium 6-aluminium 7-niobium alloy (TiAlNb) particles (p = 0.006). Commercially-pure titanium particles induced a release of 347.8 pM. In addition, TiAlV stimulated significantly more release of the other cell mediators, interleukin-1, tumour necrosis factor and interleukin-6. At lower concentrations of particles there was less mediator release and less obvious differences between materials. None of the materials caused significant toxicity. The levels of inflammatory mediators released by phagocytic cells in response to wear particles may influence the amount of periprosthetic bone loss. Our findings have shown that in vitro studies can detect differences in cellular response induced by particles of similar titanium alloys in common clinical use, although in vivo studies have shown little difference. While in vitro studies should not be used as the only form of assessment, they must be considered when assessing the relative biocompatibility of different implant materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldring, S. R., Schiller, A. L., Roelke, M., Rourke, C. M., OʼNeil, D. A., & Harris, W. H. (1983) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198365050-00001 · Cited by 849 · cited 1×
“PGE2 was considered important because it is present in periprosthetic tissue retrieved at revision surgery for loosening and has been proposed as a factor in periprosthetic bone resorption.(15-17) It is also known to be released in vitro in response to TiAlV.”
BackgroundAgins, H. J., Alcock, N. W., Bansal, M., Salvati, E. A., Wilson, P. D., Pellicci, P. M., & Bullough, P. G. (1988) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198870030-00005 · Cited by 496 · cited 2×
“The wear of titaniumalloy prostheses, including the articulating surfaces, the surfaces of the modular components, and cemented and cementless femoral stems, results in the accumulation of wear particles in the periprosthetic tissues.(1-3) Despite this, titanium alloys are useful implant materials because of their exc…”
BackgroundJiranek, W. A., Machado, M., Jasty, M., Jevsevar, D., Wolfe, H. J., Goldring, S. R., Goldberg, M. J., & Harris, W. H. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199306000-00007 · Cited by 436 · cited 1×
“Other mediators of bone resorption, such as interleukin-1 (IL-1), tumour necrosis factor (TNF) and interleukin-6 (IL-6), have been identified in periprosthetic tissue and implicated in the inflammatory response to wear particles and periprosthetic loosening.(18-22) We therefore also examined differences in the release…”
BackgroundHaynes, D. R., Rogers, S. D., Hay, S., Pearcy, M. J., & Howie, D. W. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199306000-00004 · Cited by 425 · cited 9×
“Previous in vitro studies have shown that TiAlV particles stimulate the release of PGE2, IL-1, TNF and IL-6 from human peripheral blood monocytes and rodent peritoneal macrophages.(9-12) This stimulatory effect was shown to be slightly less when human monocytes were exposed to cpTi particles.”
BackgroundResultInfluentialSelf-citationBiological and biomechanical performance of biomaterials
Black, J. (1987) · Biomaterials · doi:10.1016/0142-9612(87)90107-4 · Cited by 390
Composition and morphology of wear debris in failed uncemented total hip replacement
Shanbhag, A., Jacobs, J., Glant, T., Gilbert, J., Black, J., & Galante, J. (1994) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.76b1.8300684 · Cited by 387 · cited 1×
“In our study the wear particles of each material were of comparable size to those found in vivo.(28,30-33) Studies have shown that tissues retrieved during revision surgery for aseptic loosening have had an average of 818 g titanium per gram of tissue.”
ResultIsolation and characterization of debris in membranes around total joint prostheses.
Margevicius, K. J., Bauer, T. W., McMahon, J. T., Brown, S. A., & Merritt, K. (1994) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199411000-00010 · Cited by 270
CHIBA, J., RUBASH, H. E., JUNG, K., & IWAKI, Y. (1994) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199403000-00043 · Cited by 227 · cited 1×
“Other mediators of bone resorption, such as interleukin-1 (IL-1), tumour necrosis factor (TNF) and interleukin-6 (IL-6), have been identified in periprosthetic tissue and implicated in the inflammatory response to wear particles and periprosthetic loosening.(18-22) We therefore also examined differences in the release…”
BackgroundGlant, T. T., & Jacobs, J. J. (1994) · Journal of Orthopaedic Research · doi:10.1002/jor.1100120515 · Cited by 190
Black, J., Sherk, H., Bonini, J., Rostoker, W. R., Schajowicz, F., & Galante, J. O. (1990) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199072010-00021 · Cited by 187 · cited 1×
“The wear of titaniumalloy prostheses, including the articulating surfaces, the surfaces of the modular components, and cemented and cementless femoral stems, results in the accumulation of wear particles in the periprosthetic tissues.(1-3) Despite this, titanium alloys are useful implant materials because of their exc…”
Background
Cited by
Biological reactions to wear debris in total joint replacement
Ingham, E., & Fisher, J. (2000) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411001535219 · Cited by 708
General review of titanium toxicity
Kim, K. T., Eo, M. Y., Nguyen, T. T. H., & Kim, S. M. (2019) · International Journal of Implant Dentistry · doi:10.1186/s40729-019-0162-x · Cited by 404
Kitaura, H., Sands, M. S., Aya, K., Zhou, P., Hirayama, T., Uthgenannt, B., Wei, S., Takeshita, S., Novack, D. V., Silva, M. J., et al. (2004) · The Journal of Immunology · doi:10.4049/jimmunol.173.8.4838 · Cited by 190
“in various osteolytic disorders (11, 14, 20), we next asked whether”
BackgroundThe proliferation and phenotypic expression of human osteoblasts on tantalum metal
Findlay, D. M., Welldon, K., Atkins, G. J., Howie, D. W., Zannettino, A. C. W., & Bobyn, D. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.09.005 · Cited by 189
Self-citation
Metadata
- Authors
- Rogers, S. D., Howie, D. W., Graves, S. E., Pearcy, M. J., & Haynes, D. R.
- Venue
- The Journal of Bone and Joint Surgery. British volume
- Published
- 1997-03
- Volume
- 79-B
- Issue
- 2
- Pages
- 311-315
- ISSN
- 0301-620X (ISSN-L)
- 2044-5377
- OpenAlex
- W2163092949
- Cited by
- 161
- References
- 18
- FWCI
- 7.82
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.