Noninvasive technique for oximetry of blood in retinal vessels
The DOI matches its Crossref record.
Abstract
A noninvasive spectrophotometric technique for the measurement of oxygen saturation of the blood in discrete retinal vessels is described. The instrument, the retinal vessel oximeter, uses scanning fundus reflectometry to determine the optical density of a retinal vessel at three wavelengths (558, 569, and 686 nm). Oxygen saturation is determined after compensation for the effects of light scattering by the red blood cells by relating the measured densities with the corresponding extinction coefficients nf oxyhemoglobin and deoxy-genated hemoglobin. The vessel diameter is also measured continuously. All data acquisition and analysis are performed on-line by means of a microcomputer, and a vessel tracking system is used to compensate for the effects of eye movements. Oxygen saturation measurements for blood flowing through glass capillaries are presented as well as representative results of oxygen saturation measurements on normal human subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Detection of blood vessels in retinal images using two-dimensional matched filters
Chaudhuri, S., Chatterjee, S., Katz, N., Nelson, M., & Goldbaum, M. (1989) · IEEE Transactions on Medical Imaging · doi:10.1109/42.34715 · Cited by 1,668
Retinal Oxygen: Fundamental and Clinical Aspects
Wangsa-Wirawan, N. D. (2003) · Archives of Ophthalmology · doi:10.1001/archopht.121.4.547 · Cited by 546
Optical coherence tomography today: speed, contrast, and multimodality
Drexler, W., Liu, M., Kumar, A., Kamali, T., Unterhuber, A., & Leitgeb, R. A. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.7.071412 · Cited by 473
Spectral reflectance of the human ocular fundus
Delori, F. C., & Pflibsen, K. P. (1989) · Applied Optics · doi:10.1364/ao.28.001061 · Cited by 377
Self-citationHardarson, S. H., Harris, A., Karlsson, R. A., Halldorsson, G. H., Kagemann, L., Rechtman, E., Zoega, G. M., Eysteinsson, T., Benediktsson, J. A., Thorsteinsson, A., et al. (2006) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.06-0039 · Cited by 276
Snapshot hyperspectral imaging in ophthalmology
Johnson, W. R., Wilson, D. W., Fink, W., Humayun, M., & Bearman, G. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2434950 · Cited by 274
Oximetry of retinal vessels by dual-wavelength imaging: calibration and influence of pigmentation
Beach, J. M., Schwenzer, K. J., Srinivas, S., Kim, D., & Tiedeman, J. S. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.86.2.748 · Cited by 263
Adaptive optics imaging of the human retina
Burns, S. A., Elsner, A. E., Sapoznik, K. A., Warner, R. L., & Gast, T. J. (2019) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.08.002 · Cited by 263
Contemporary retinal imaging techniques in diabetic retinopathy: a review
Cole, E. D., Novais, E. A., Louzada, R. N., & Waheed, N. K. (2016) · Clinical & Experimental Ophthalmology · doi:10.1111/ceo.12711 · Cited by 91
Metadata
- Authors
- Delori, F. C.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1988-03-15
- Volume
- 27
- Issue
- 6
- Pages
- 1113
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2012027777
- Cited by
- 207
- References
- 0
- FWCI
- 3.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.