Reduced light-scattering properties for mixtures of spherical particles: a simple approximation derived from Mie calculations
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The reduced scattering cross section per unit of volume Sigma'(s) identical withSigma(s)(1 - g) is an important parameter to describe light propagation in media with scattering and absorption. Mie calculations of the asymmetry factor g for nonabsorbing spheres and Q(sca), the ratio of the scattering cross section Sigma(s) and the particle cross section, show that Q(sca)(1 - g) = 3.28x(0.37)(m - 1)(2.09) is true to within a few percent, when the Mie parameters for relative refractive index m and size x are in the ranges of 1 < m </= 1.1 and 5 < x < 50, respectively. A ratio of reduced scattering cross sections for radiation at two wavelengths is also independent of the size within the range mentioned, even for mixtures of different size spheres. The results seem promising for biomedical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Absorption and Scattering of Light by Small Particles
Bohren, C. F., & Huffman, D. R. (1998) · doi:10.1002/9783527618156 · Cited by 18,474
Cited by
Bashkatov, A. N., Genina, E. A., Kochubey, V. I., & Tuchin, V. V. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/004 · Cited by 1,720
OPTICAL PROPERTIES OF SKIN, SUBCUTANEOUS, AND MUSCLE TISSUES: A REVIEW
BASHKATOV, A. N., GENINA, E. A., & TUCHIN, V. V. (2011) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545811001319 · Cited by 761
Mourant, J. R., Freyer, J. P., Hielscher, A. H., Eick, A. A., Shen, D., & Johnson, T. M. (1998) · Applied Optics · doi:10.1364/ao.37.003586 · Cited by 681
Mourant, J. R., Fuselier, T., Boyer, J., Johnson, T. M., & Bigio, I. J. (1997) · Applied Optics · doi:10.1364/ao.36.000949 · Cited by 529
Optical properties of human skin
Lister, T., Wright, P. A., & Chappell, P. H. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.9.090901 · Cited by 467
Light propagation in tissues with controlled optical properties
Tuchin, V. V. (1997) · Journal of Biomedical Optics · doi:10.1117/1.429841 · Cited by 411
Recent progress in tissue optical clearing
Zhu, D., Larin, K. V., Luo, Q., & Tuchin, V. V. (2013) · Laser & Photonics Reviews · doi:10.1002/lpor.201200056 · Cited by 394
Optical properties of fat emulsions
Michels, R., Foschum, F., & Kienle, A. (2008) · Optics Express · doi:10.1364/oe.16.005907 · Cited by 387
Doornbos, R. M. P., Lang, R., Aalders, M. C., Cross, F. W., & Sterenborg, H. J. C. M. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/4/012 · Cited by 380
Review of Monte Carlo modeling of light transport in tissues
Zhu, C., & Liu, Q. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.5.050902 · Cited by 352
Spectroscopic and Clinical Aspects of Noninvasive Glucose Measurements
Khalil, O. S. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.2.165 · Cited by 331
Mie and Rayleigh modeling of visible-light scattering in neonatal skin
Saidi, I. S., Jacques, S. L., & Tittel, F. K. (1995) · Applied Optics · doi:10.1364/ao.34.007410 · Cited by 294
Dunn, A. K., Devor, A., Dale, A. M., & Boas, D. A. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.04.024 · Cited by 285
Bevilacqua, F., Berger, A. J., Cerussi, A. E., Jakubowski, D., & Tromberg, B. J. (2000) · Applied Optics · doi:10.1364/ao.39.006498 · Cited by 284
Diffuse optical imaging using spatially and temporally modulated light
O’Sullivan, T. D., Cerussi, A. E., Cuccia, D. J., & Tromberg, B. J. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.7.071311 · Cited by 270
Non-Invasive Glucose Measurement Technologies: An Update from 1999 to the Dawn of the New Millennium
Khalil, O. S. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2004.6.660 · Cited by 255
Gender variations in the optical properties of skin in murine animal models
Calabro, K., Curtis, A., Galarneau, J.-R., Krucker, T., & Bigio, I. J. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3525565 · Cited by 58
Metadata
- Authors
- Graaff, R., Aarnoudse, J. G., Zijp, J. R., Sloot, P. M. A., de Mul, F. F. M., Greve, J., & Koelink, M. H.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1992-04-01
- Volume
- 31
- Issue
- 10
- Pages
- 1370
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2167450076
- Cited by
- 241
- References
- 1
- FWCI
- 4.09
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.