The DOI matches its Crossref record.
Single-photon detection beyond 1 μm: performance of commercially available InGaAs/InP detectors
Abstract
Commercially available InGaAs/lnP avalanche photodiodes, designed for optical receivers and range finders, can be operated biased above the breakdown voltage, achieving single-photon sensitivity. We describe in detail how to select the device for photon-counting applications among commercial samples. Because of the high dark-counting rate the detector must be cooled to below 100 K and operated in a gated mode. We achieved a noise equivalent power of 3 × 10(-16) W/Hz(1/2) to a 1.55-µm wavelength and a time resolution well below 1 ns with a best value of 200-ps FWHM. Finally we compare these figures with the performance of state-of-the-art detectors in the near IR, and we highlight the potentials of properly designed InGaAs/lnP avalanche photodiodes in single-photon detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gisin, N., Ribordy, G., Tittel, W., & Zbinden, H. (2002) · Reviews of Modern Physics · doi:10.1103/revmodphys.74.145 · Cited by 8,515
Single-photon detectors for optical quantum information applications
Hadfield, R. H. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.230 · Cited by 1,726
Invited Review Article: Single-photon sources and detectors
Eisaman, M. D., Fan, J., Migdall, A., & Polyakov, S. V. (2011) · Review of Scientific Instruments · doi:10.1063/1.3610677 · Cited by 1,358
Avalanche photodiodes and quenching circuits for single-photon detection
Cova, S., Ghioni, M., Lacaita, A., Samori, C., & Zappa, F. (1996) · Applied Optics · doi:10.1364/ao.35.001956 · Cited by 1,114
Self-citationAdvances in InGaAs/InP single-photon detector systems for quantum communication
Zhang, J., Itzler, M. A., Zbinden, H., & Pan, J.-W. (2015) · Light: Science & Applications · doi:10.1038/lsa.2015.59 · Cited by 436
Effects of detector efficiency mismatch on security of quantum cryptosystems
Makarov, V., Anisimov, A., & Skaar, J. (2006) · Physical Review A · doi:10.1103/physreva.74.022313 · Cited by 395
Evolution and prospects for single-photon avalanche diodes and quenching circuits
Cova, S., Ghioni, M., Lotito, A., Rech, I., & Zappa, F. (2004) · Journal of Modern Optics · doi:10.1080/09500340408235272 · Cited by 322
Self-citationAll-fiber photon-pair source for quantum communications
Fiorentino, M., Voss, P. L., Sharping, J. E., & Kumar, P. (2002) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2002.1012406 · Cited by 271
High speed single photon detection in the near infrared
Yuan, Z. L., Kardynal, B. E., Sharpe, A. W., & Shields, A. J. (2007) · Applied Physics Letters · doi:10.1063/1.2760135 · Cited by 269
Single-photon generation and detection
Buller, G. S., & Collins, R. J. (2010) · Measurement Science and Technology · doi:10.1088/0957-0233/21/1/012002 · Cited by 268
Performance and design of InGaAs/InP photodiodes for single-photon counting at 155 µm
Hiskett, P. A., Buller, G. S., Loudon, A. Y., Smith, J. M., Gontijo, I., Walker, A. C., Townsend, P. D., & Robertson, M. J. (2000) · Applied Optics · doi:10.1364/ao.39.006818 · Cited by 126
Kahl, O., Ferrari, S., Kovalyuk, V., Goltsman, G. N., Korneev, A., & Pernice, W. H. P. (2015) · Scientific Reports · doi:10.1038/srep10941 · Cited by 102
Rarity, J. G., Wall, T. E., Ridley, K. D., Owens, P. C. M., & Tapster, P. R. (2000) · Applied Optics · doi:10.1364/ao.39.006746 · Cited by 95
Castelletto, S. A., & Scholten, R. E. (2008) · The European Physical Journal Applied Physics · doi:10.1051/epjap:2008029 · Cited by 68
Metadata
- Authors
- Lacaita, A., Zappa, F., Cova, S., & Lovati, P.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1996-06-01
- Volume
- 35
- Issue
- 16
- Pages
- 2986
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2030781869
- Cited by
- 167
- References
- 0
- FWCI
- 11.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.