The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Video-rate confocal scanning laser microscope for imaging human tissues in vivo
Abstract
We have built a video-rate confocal scanning laser microscope for reflectance imaging of human skin and oral mucosa in vivo. Design and imaging parameters were determined for optimum resolution and contrast. Mechanical skin-holding fixtures and oral tissue clamps were made for stable objective lens-to-tissue contact such that gross tissue motion relative to the microscope was minimized. Confocal imaging was possible to maximum depths of 350 microm in human skin and 450 microm in oral mucosa, with measured lateral resolution of 0.5-1 microm and axial resolution (section thickness) of 3-5 microm at the 1064-nm wavelength. This resolution is comparable with that of conventional microscopy of excised biopsies (histology). Normal and abnormal tissue morphology and dynamic processes were observed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Handbook Of Biological Confocal Microscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-45524-2 · Cited by 3,637
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Anderson, R. R., & Parrish, J. A. (1981) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12479191 · Cited by 2,456
Self-citationPeli, E. (1990) · Journal of the Optical Society of America A · doi:10.1364/josaa.7.002032 · Cited by 1,298
Light scattering in lntralipid-10% in the wavelength range of 400–1100 nm
van Staveren, H. J., Moes, C. J. M., van Marie, J., Prahl, S. A., & van Gemert, M. J. C. (1991) · Applied Optics · doi:10.1364/ao.30.004507 · Cited by 1,106
In Vivo Confocal Scanning Laser Microscopy of Human Skin: Melanin Provides Strong Contrast
Rajadhyaksha, M., Grossman, M., Esterowitz, D., Webb, R. H., & Rox Anderson, R. (1995) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12606215 · Cited by 1,093
Self-citationPeli, E. (1988) · Annual Meeting Optical Society of America · doi:10.1364/oam.1988.fd8 · Cited by 937
Van Gemert, M. J. C., Jacques, S. L., Sterenborg, H. J. C. M., & Star, W. M. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.42108 · Cited by 807
Aberrations in confocal fluorescence microscopy induced by mismatches in refractive index
HELL, S., REINER, G., CREMER, C., & STELZER, E. H. K. (1993) · Journal of Microscopy · doi:10.1111/j.1365-2818.1993.tb03315.x · Cited by 640
Confocal scanning laser ophthalmoscope
Webb, R. H., Hughes, G. W., & Delori, F. C. (1987) · Applied Optics · doi:10.1364/ao.26.001492 · Cited by 597
Self-citation
Cited by
Chemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy
Evans, C. L., Potma, E. O., Puoris'haag, M., Côté, D., Lin, C. P., & Xie, X. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0508282102 · Cited by 957
Rajadhyaksha, M., González, S., Zavislan, J. M., Rox Anderson, R., & Webb, R. H. (1999) · Journal of Investigative Dermatology · doi:10.1046/j.1523-1747.1999.00690.x · Cited by 834
Self-citation
Metadata
- Authors
- Rajadhyaksha, M., Anderson, R. R., & Webb, R. H.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1999-04-01
- Volume
- 38
- Issue
- 10
- Pages
- 2105
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2093516870
- Cited by
- 300
- References
- 25
- FWCI
- 7.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Video-rate confocal scanning laser microscope for imaging human tissues in vivo. https://app.cochat.ai/papers/10.1364/ao.38.002105
- The paper
- Rajadhyaksha, M., Anderson, R. R., & Webb, R. H. (1999). Video-rate confocal scanning laser microscope for imaging human tissues in vivo. Applied Optics. https://doi.org/10.1364/ao.38.002105
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.