DistancePPG: Robust non-contact vital signs monitoring using a camera
Open accessAbstract
Vital signs such as pulse rate and breathing rate are currently measured using contact probes. But, non-contact methods for measuring vital signs are desirable both in hospital settings (e.g. in NICU) and for ubiquitous in-situ health tracking (e.g. on mobile phone and computers with webcams). Recently, camera-based non-contact vital sign monitoring have been shown to be feasible. However, camera-based vital sign monitoring is challenging for people with darker skin tone, under low lighting conditions, and/or during movement of an individual in front of the camera. In this paper, we propose distancePPG, a new camera-based vital sign estimation algorithm which addresses these challenges. DistancePPG proposes a new method of combining skin-color change signals from different tracked regions of the face using a weighted average, where the weights depend on the blood perfusion and incident light intensity in the region, to improve the signal-to-noise ratio (SNR) of camera-based estimate. One of our key contributions is a new automatic method for determining the weights based only on the video recording of the subject. The gains in SNR of camera-based PPG estimated using distancePPG translate into reduction of the error in vital sign estimation, and thus expand the scope of camera-based vital sign monitoring to potentially challenging scenarios. Further, a dataset will be released, comprising of synchronized video recordings of face and pulse oximeter based ground truth recordings from the earlobe for people with different skin tones, under different lighting conditions and for various motion scenarios.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and other subjective scales were employed in 13 studies (35.14%) [30,42,43,44,45,50,52,56,72,78,80,87,88].”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [78]
Citations
Cites
Fischler, M. A., & Bolles, R. C. (1981) · Communications of the ACM · doi:10.1145/358669.358692 · Cited by 25,893
Shi, J., & Tomasi (1994) · Proceedings of IEEE Conference on Computer Vision and Pattern Recognition CVPR-94 · doi:10.1109/cvpr.1994.323794 · Cited by 7,724
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Remote plethysmographic imaging using ambient light
Verkruysse, W., Svaasand, L. O., & Nelson, J. S. (2008) · Optics Express · doi:10.1364/oe.16.021434 · Cited by 1,728
Non-contact, automated cardiac pulse measurements using video imaging and blind source separation
Poh, M., McDuff, D., & Picard, R. W. (2010) · Optics Express · doi:10.1364/oe.18.010762 · Cited by 1,652
Advancements in Noncontact, Multiparameter Physiological Measurements Using a Webcam
Poh, M., McDuff, D., & Picard, R. W. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2086456 · Cited by 1,514
Linear diversity combining techniques
Brennan, D. G. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2002.808163 · Cited by 822
Deformable Model Fitting by Regularized Landmark Mean-Shift
Saragih, J. M., Lucey, S., & Cohn, J. F. (2011) · International Journal of Computer Vision · doi:10.1007/s11263-010-0380-4 · Cited by 787
Improvements in Remote Cardiopulmonary Measurement Using a Five Band Digital Camera
McDuff, D., Gontarek, S., & Picard, R. W. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2323695 · Cited by 290
Wieringa, F. P., Mastik, F., & van der Steen, A. F. W. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-5763-2 · Cited by 284
Aarts, L. A. M., Jeanne, V., Cleary, J. P., Lieber, C. A., Nelson, J. S., Oetomo, S. B., & Verkruysse, W. (2013) · Early Human Development · doi:10.1016/j.earlhumdev.2013.09.016 · Cited by 241
The difference in pulse transit time to the toe and finger measured by photoplethysmography
Nitzan, M., Khanokh, B., & Slovik, Y. (2001) · Physiological Measurement · doi:10.1088/0967-3334/23/1/308 · Cited by 218
Humphreys, K., Ward, T. E., & Markham, C. (2007) · Review of Scientific Instruments · doi:10.1063/1.2724789 · Cited by 214
Sun, Y., Hu, S., Azorin-Peris, V., Chambers, J. A., Zhu, Y., & Greenwald, S. E. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3602852 · Cited by 213
Heathers, J. A. J. (2013) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2013.05.017 · Cited by 122
Signal recovery in imaging photoplethysmography
Holton, B. D., Mannapperuma, K., Lesniewski, P. J., & Thomas, J. C. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/11/1499 · Cited by 73
Evaluation of a New Pulse Oximeter Sensor
Fernandez, M., Burns, K., Calhoun, B., George, S., Martin, B., & Weaver, C. (2007) · American Journal of Critical Care · doi:10.4037/ajcc2007.16.2.146 · Cited by 67
Opto‐Physiological Modeling Applied to Photoplethysmographic Cardiovascular Assessment
Hu, S., Azorin-Peris, V., & Zheng, J. (2013) · Journal of Healthcare Engineering · doi:10.1260/2040-2295.4.4.505 · Cited by 30
Cited by
Sorted by citations
Algorithmic principles of remote PPG
Wang, W., den Brinker, A. C., Stuijk, S., & de Haan, G. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2609282 · Cited by 1,234
“For a thorough evaluation, we benchmark it with seven commonly used or state-of-the-art rPPG methods: 1) G (2007) [1], the single wavelength method that is still popular as evidenced by recent researches [7], [10].”
MethodPhotoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. V. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 589
RhythmNet: End-to-End Heart Rate Estimation From Face via Spatial-Temporal Representation
Niu, X., Shan, S., Han, H., & Chen, X. (2019) · IEEE Transactions on Image Processing · doi:10.1109/tip.2019.2947204 · Cited by 421
“[21] Webcam G Patch level signals combination FFT using weighted average”
MethodWireless Sensing for Human Activity: A Survey
Liu, J., Liu, H., Chen, Y., Wang, Y., & Wang, C. (2020) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2019.2934489 · Cited by 414
“, DistancePPG [129]) and sensor-based (e.”
A Survey on Wireless Body Area Networks for eHealthcare Systems in Residential Environments
Ghamari, M., Janko, B., Sherratt, R. S., Harwin, W., Piechocki, R. J., & Soltanpur, C. (2016) · Sensors · doi:10.3390/s16060831 · Cited by 300
“For example, researchers from Rice University have been developing a non-contact video-camera system that can precisely monitor and measure temperature, pulse and breathing rate from changes in a patient’s skin color [99].”
Metadata
- Authors
- Kumar, M., Veeraraghavan, A., & Sabharwal, A.
- Affiliations
- Rice University (US)
- Venue
- Biomedical Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2015-04-06
- Volume
- 6
- Issue
- 5
- Pages
- 1565
- ISSN
- 2156-7085 (ISSN-L)
- PMC
- PMC4467696
- OpenAlex
- W2029745771
- Cited by
- 417
- References
- 17
- Citations by year
- 2026: 9 · 2025: 21 · 2024: 36 · 2023: 46 · 2022: 49 · 2021: 57 · 2020: 35 · 2019: 47 · 2018: 46 · 2017: 33 · 2016: 31 · 2015: 7
- FWCI
- 19.38
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Biomedical Optics Express (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Rice Research Repository (Rice University) (submittedVersion)
- Funders
- National Science Foundation (NSF) (1126478, 1429047)
- Texas Higher Education Coordinating Board (THECB) (THECB-NHARP 13308)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Keywords
- respiratory rate estimation, photoplethysmography, skin color change, blood perfusion, incident light intensity, signal-to-noise ratio, darker skin tones, motion robustness
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review