Red emissive AIE nanodots with high two-photon absorption efficiency at 1040 nm for deep-tissue in vivo imaging
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Deep-tissue penetration is highly required in in vivo optical bioimaging. We synthesized a type of red emissive fluorophore BT with aggregation-induced emission (AIE) property. BT molecules were then encapsulated with amphiphilic polymers to form nanodots, and a large two-photon absorption (2PA) cross-section of 2.9 × 10(6) GM at 1040 nm was observed from each BT nanodot, which was much larger than those at the wavelengths of 770 to 860 nm. In addition, 1040 nm light was found to have better penetration and focusing capability than 800 nm light in biological tissue, according to the Monte Carlo simulation. The toxicity and tissue distribution of BT nanodots were studied, and they were found to have good biocompatibility. BT nanodots were then utilized for in vivo imaging of mouse ear and brain, and an imaging depth of 700 μm was obtained with the femtosecond (fs) excitation of 1040 nm. The red emissive AIE nanodots with high 2PA efficiency at 1040 nm would be useful for deep-tissue functional bioimaging in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
BODIPY Dyes and Their Derivatives: Syntheses and Spectroscopic Properties
Loudet, A., & Burgess, K. (2007) · Chemical Reviews · doi:10.1021/cr078381n · Cited by 5,238
In vivo three-photon microscopy of subcortical structures within an intact mouse brain
Horton, N. G., Wang, K., Kobat, D., Clark, C. G., Wise, F. W., Schaffer, C. B., & Xu, C. (2013) · Nature Photonics · doi:10.1038/nphoton.2012.336 · Cited by 1,505
Cited by
AIE Luminogens for Bioimaging and Theranostics: From Organelles to Animals
Qian, J., & Tang, B. Z. (2017) · Chem · doi:10.1016/j.chempr.2017.05.010 · Cited by 577
Self-citationColloidal Synthesis of Semiconductor Quantum Dots toward Large-Scale Production: A Review
Pu, Y., Cai, F., Wang, D., Wang, J.-X., & Chen, J.-F. (2018) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.7b04836 · Cited by 351
Self-citationQi, J., Sun, C., Li, D., Zhang, H., Yu, W., Zebibula, A., Lam, J. W. Y., Xi, W., Zhu, L., Cai, F., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b02452 · Cited by 226
Self-citationWang, Y., Chen, M., Alifu, N., Li, S., Qin, W., Qin, A., Tang, B. Z., & Qian, J. (2017) · ACS Nano · doi:10.1021/acsnano.7b05645 · Cited by 177
Self-citationWang, S., Liu, J., Goh, C. C., Ng, L. G., & Liu, B. (2019) · Advanced Materials · doi:10.1002/adma.201904447 · Cited by 148
Self-citation
Metadata
- Authors
- Wang, Y., Hu, R., Xi, W., Cai, F., Wang, S., Zhu, Z., Bai, R., & Qian, J.
- Venue
- Biomedical Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2015-09-03
- Volume
- 6
- Issue
- 10
- Pages
- 3783
- ISSN
- 2156-7085 (ISSN-L)
- OpenAlex
- W1851663989
- Cited by
- 68
- References
- 2
- FWCI
- 4.26
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.