The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
ReLayNet: retinal layer and fluid segmentation of macular optical coherence tomography using fully convolutional networks
Open accessAbstract
Optical coherence tomography (OCT) is used for non-invasive diagnosis of diabetic macular edema assessing the retinal layers. In this paper, we propose a new fully convolutional deep architecture, termed ReLayNet, for end-to-end segmentation of retinal layers and fluid masses in eye OCT scans. ReLayNet uses a contracting path of convolutional blocks (encoders) to learn a hierarchy of contextual features, followed by an expansive path of convolutional blocks (decoders) for semantic segmentation. ReLayNet is trained to optimize a joint loss function comprising of weighted logistic regression and Dice overlap loss. The framework is validated on a publicly available benchmark dataset with comparisons against five state-of-the-art segmentation methods including two deep learning based approaches to substantiate its effectiveness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chen, L.-C., Papandreou, G., Kokkinos, I., Murphy, K., & Yuille, A. L. (2016) · arXiv · doi:10.48550/arxiv.1606.00915 · Cited by 22,392
Chen, L.-C., Papandreou, G., Kokkinos, I., Murphy, K., & Yuille, A. L. (2018) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2017.2699184 · Cited by 22,392
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Fully convolutional networks for semantic segmentation
Shelhamer, E., Long, J., & Darrell, T. (2017) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2016.2572683 · Cited by 11,898
von Braunmühl, T. (2015) · Der Hautarzt · doi:10.1007/s00105-015-3607-z · Cited by 1,033
Chiu, S. J., Li, X. T., Nicholas, P., Toth, C. A., Izatt, J. A., & Farsiu, S. (2010) · Optics Express · doi:10.1364/oe.18.019413 · Cited by 733
In vivo human retinal imaging by ultrahigh-speed spectral domain optical coherence tomography
Nassif, N., Cense, B., Hyle Park, B., Yun, S. H., Chen, T. C., Bouma, B. E., Tearney, G. J., & de Boer, J. F. (2004) · Optics Letters · doi:10.1364/ol.29.000480 · Cited by 498
Fang, L., Cunefare, D., Wang, C., Guymer, R. H., Li, S., & Farsiu, S. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.002732 · Cited by 481
Chiu, S. J., Allingham, M. J., Mettu, P. S., Cousins, S. W., Izatt, J. A., & Farsiu, S. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.001172 · Cited by 377
Mechanisms of fluid accumulation in retinal edema
Marmor, M. F. (1999) · Documenta Ophthalmologica · doi:10.1023/a:1002192829817 · Cited by 260
Anger, E., Unterhuber, A., Hermann, B. M., Sattmann, H., Schubert, C., Morgan, J. E., Cowey, A., Ahnelt, P. K., & Drexler, W. (2004) · Experimental Eye Research · doi:10.1016/j.exer.2004.01.011 · Cited by 183
Kafieh, R., Rabbani, H., Abramoff, M. D., & Sonka, M. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.05.006 · Cited by 160
Yeh, A. T., Kao, B., Jung, W. G., Chen, Z., Nelson, J. S., & Tromberg, B. J. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1648646 · Cited by 129
Tian, J., Varga, B. E., Tátrai, E., Pálya, F., Somfai, G. M., Smiddy, W. E., & DeBuc, D. C. (2016) · Journal of Biophotonics · doi:10.1002/jbio.201500239 · Cited by 93
Learning layer-specific edges for segmenting retinal layers with large deformations
Karri, S. P. K., Chakraborthi, D., & Chatterjee, J. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.002888 · Cited by 66
Self-citationRossant, F., Isabelle Bloch, A., Ghorbel, I., & Pâques, M. (2015) · Pattern Recognition · doi:10.1016/j.patcog.2015.06.009 · Cited by 42
Weng, W., Liang, Y. M., Kimball, E. S., Hobbs, T. M., Kong, S. X., Sakurada, B., & Bouchard, J. R. (2016) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2016.04.043 · Cited by 34
Performance Analysis of Network Model to Identify Healthy and Cancerous Colon Genes
Roy, T., & Barman, S. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2408366 · Cited by 23
Cited by
Clinically applicable deep learning for diagnosis and referral in retinal disease
De Fauw, J., Ledsam, J. R., Romera-Paredes, B., Nikolov, S., Tomasev, N., Blackwell, S., Askham, H., Glorot, X., O’Donoghue, B., Visentin, D., et al. (2018) · Nature Medicine · doi:10.1038/s41591-018-0107-6 · Cited by 2,639
CE-Net: Context Encoder Network for 2D Medical Image Segmentation
Gu, Z., Cheng, J., Fu, H., Zhou, K., Hao, H., Zhao, Y., Zhang, T., Gao, S., & Liu, J. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2903562 · Cited by 2,267
Artificial intelligence and deep learning in ophthalmology
Ting, D. S. W., Pasquale, L. R., Peng, L., Campbell, J. P., Lee, A. Y., Raman, R., Tan, G. S. W., Schmetterer, L., Keane, P. A., & Wong, T. Y. (2019) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2018-313173 · Cited by 1,554
Artificial Intelligence and Deep Learning in Ophthalmology
Wang, Z., Keane, P. A., Chiang, M., Cheung, C. Y., Wong, T. Y., & Ting, D. S. W. (2022) · Artificial Intelligence in Medicine · doi:10.1007/978-3-030-64573-1_200 · Cited by 1,524
A survey on deep learning techniques for image and video semantic segmentation
Garcia-Garcia, A., Orts-Escolano, S., Oprea, S., Villena-Martinez, V., Martinez-Gonzalez, P., & Garcia-Rodriguez, J. (2018) · Applied Soft Computing · doi:10.1016/j.asoc.2018.05.018 · Cited by 1,490
Metadata
- Authors
- Roy, A. G., Conjeti, S., Karri, S. P. K., Sheet, D., Katouzian, A., Wachinger, C., & Navab, N.
- Venue
- Biomedical Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2017-07-13
- Volume
- 8
- Issue
- 8
- Pages
- 3627
- ISSN
- 2156-7085 (ISSN-L)
- OpenAlex
- W2606534623
- Cited by
- 613
- References
- 18
- FWCI
- 42.41
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.