Optical and Photoelectric Analog of the Eye
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
A photoelectric analog of the visual system is constructed in conformance with anatomical data. The analog has the form of a color television camera chain feeding electrical signals to a “computer” (the brain). Evaluation of characteristics is limited to elements preceding the computer, and particularly to the “luminance channel” of the color system.The primary photoelectric transfer characteristics n¯1=f(Er) of the receptors (rods and cones) are computed as a function of retinal illumination (Er) from threshold signal-to-noise ratios in the effective image area of point sources, disks, and other test objects. The effective image area, which is the convolution of the object area with the sampling area of the visual system, is determined from its Fourier spectrum. The constants of the transfer functions are established from the optical constants of the eye, its storage-time function, and the maximum transfer ratio of statistical units of the rod and cone systems. There is little room for variation of constants, if they are to remain in agreement with observed values.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Sensitivity Performance of the Human Eye on an Absolute Scale*
Rose, A. (1948) · Journal of the Optical Society of America · doi:10.1364/josa.38.000196 · Cited by 931
Contrast Thresholds of the Human Eye
Blackwell, H. R. (1946) · Journal of the Optical Society of America · doi:10.1364/josa.36.000624 · Cited by 869
The Disappearance of Steadily Fixated Visual Test Objects*
Riggs, L. A., Ratliff, F., Cornsweet, J. C., & Cornsweet, T. N. (1953) · Journal of the Optical Society of America · doi:10.1364/josa.43.000495 · Cited by 554
de Lange Dzn, H. (1954) · Journal of the Optical Society of America · doi:10.1364/josa.44.000380 · Cited by 222
ABSORPTION OF VISIBLE LIGHT BY THE REFRACTIVE MEDIA OF THE HUMAN EYE
LUDVIGH, E., & McCARTHY, E. F. (1938) · Archives of Ophthalmology · doi:10.1001/archopht.1938.00850190049005 · Cited by 135
Vision and Resolution in the Central Retina*†
O'Brien, B. J. (1951) · Journal of the Optical Society of America · doi:10.1364/josa.41.000882 · Cited by 120
INTERMITTENT STIMULATION BY LIGHT
Hecht, S., & Smith, E. L. (1936) · The Journal of General Physiology · doi:10.1085/jgp.19.6.979 · Cited by 83
The Nerve Messages in the Fibers of the Visual Pathway*
Hartline, H. K. (1940) · Journal of the Optical Society of America · doi:10.1364/josa.30.000239 · Cited by 74
Cited by
Application of fourier analysis to the visibility of gratings
Campbell, F. W., & Robson, J. G. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008574 · Cited by 3,019
The contrast sensitivity of retinal ganglion cells of the cat
Enroth-Cugell, C., & Robson, J. G. (1966) · The Journal of Physiology · doi:10.1113/jphysiol.1966.sp008107 · Cited by 2,625
Optical and retinal factors affecting visual resolution.
Campbell, F. W., & Green, D. G. (1965) · The Journal of Physiology · doi:10.1113/jphysiol.1965.sp007784 · Cited by 1,595
Spatial summation in the receptive fields of simple cells in the cat's striate cortex.
Movshon, J. A., Thompson, I. D., & Tolhurst, D. J. (1978) · The Journal of Physiology · doi:10.1113/jphysiol.1978.sp012488 · Cited by 890
Orientational selectivity of the human visual system
Campbell, F. W., & Kulikowski, J. J. (1966) · The Journal of Physiology · doi:10.1113/jphysiol.1966.sp008101 · Cited by 688
Spatial Modulation Transfer in the Human Eye
Van Nes, F. L., & Bouman, M. A. (1967) · Journal of the Optical Society of America · doi:10.1364/josa.57.000401 · Cited by 621
Spatial-Frequency Channels in Human Vision*
Sachs, M. B., Nachmias, J., & Robson, J. G. (1971) · Journal of the Optical Society of America · doi:10.1364/josa.61.001176 · Cited by 505
The effect of orientation on the visual resolution of gratings
Campbell, F. W., Kulikowski, J. J., & Levinson, J. (1966) · The Journal of Physiology · doi:10.1113/jphysiol.1966.sp008100 · Cited by 481
Accurate control of contrast on microcomputer displays
Pelli, D. G., & Zhang, L. (1991) · Vision Research · doi:10.1016/0042-6989(91)90055-a · Cited by 474
Monocular versus Binocular Visual Acuity
CAMPBELL, F. W., & GREEN, D. G. (1965) · Nature · doi:10.1038/208191a0 · Cited by 470
Hess, R. F., & Howell, E. R. (1977) · Vision Research · doi:10.1016/0042-6989(77)90009-8 · Cited by 470
De Valois, R. L., Morgan, H., & Snodderly, D. M. (1974) · Vision Research · doi:10.1016/0042-6989(74)90118-7 · Cited by 442
Seven Challenges in Image Quality Assessment: Past, Present, and Future Research
Chandler, D. M. (2013) · ISRN Signal Processing · doi:10.1155/2013/905685 · Cited by 427
Morrone, M. C., Burr, D. C., & Maffei, L. (1982) · Proceedings of the Royal Society of London. Series B. Biological Sciences · doi:10.1098/rspb.1982.0078 · Cited by 419
Measuring contrast sensitivity
Pelli, D. G., & Bex, P. (2013) · Vision Research · doi:10.1016/j.visres.2013.04.015 · Cited by 394
Rose, A., & Biberman, L. (1975) · Physics Today · doi:10.1063/1.3069240 · Cited by 378
Contrast sensitivity at high velocities
Burr, D. C., & Ross, J. (1982) · Vision Research · doi:10.1016/0042-6989(82)90196-1 · Cited by 344
Infant pattern vision: A new approach based on the contrast sensitivity function
Banks, M. S., & Salapatek, P. (1981) · Journal of Experimental Child Psychology · doi:10.1016/0022-0965(81)90002-3 · Cited by 341
Frequency Doubling in Visual Responses*†
Kelly, D. H. (1966) · Journal of the Optical Society of America · doi:10.1364/josa.56.001628 · Cited by 327
Spatial interaction in human cone vision
Westheimer, G. (1967) · The Journal of Physiology · doi:10.1113/jphysiol.1967.sp008198 · Cited by 317
Spatiotemporal Modulation Transfer in the Human Eye
Van Nes, F. L., Koenderink, J. J., Nas, H., & Bouman, M. A. (1967) · Journal of the Optical Society of America · doi:10.1364/josa.57.001082 · Cited by 316
Spatial arrangement of line, edge and grating detectors revealed by subthreshold summation
Kulikowski, J. J., & King-Smith, P. E. (1973) · Vision Research · doi:10.1016/0042-6989(73)90006-0 · Cited by 296
The Gaussian derivative model for spatial vision: I. Retinal mechanisms
Young, R. A. (1987) · Spatial Vision · doi:10.1163/156856887x00222 · Cited by 288
Does print size matter for reading? A review of findings from vision science and typography
Legge, G. E., & Bigelow, C. A. (2011) · Journal of Vision · doi:10.1167/11.5.8 · Cited by 272
Development of contrast sensitivity over the first 3 months of life in the human infant
Atkinson, J., Braddick, O., & Moar, K. (1977) · Vision Research · doi:10.1016/0042-6989(77)90007-4 · Cited by 269
Window of visibility: a psychophysical theory of fidelity in time-sampled visual motion displays
Watson, A. B., Ahumada, A. J., & Farrell, J. E. (1986) · Journal of the Optical Society of America A · doi:10.1364/josaa.3.000300 · Cited by 261
The orientation specificity of two visual after‐effects
Blakemore, C., & Nachmias, J. (1971) · The Journal of Physiology · doi:10.1113/jphysiol.1971.sp009374 · Cited by 260
The perceived spatial frequency shift: evidence for frequency‐selective neurones in the human brain
Blakemore, C., Nachmias, J., & Sutton, P. (1970) · The Journal of Physiology · doi:10.1113/jphysiol.1970.sp009238 · Cited by 242
What causes trichromacy? A theoretical analysis using comb-filtered spectra
Barlow, H. B. (1982) · Vision Research · doi:10.1016/0042-6989(82)90099-2 · Cited by 235
“…vision in terms of localized spots and patches, but since the introduction and popularization of sinusoidally varying stimuli (de Lange, 1952; Schade, 1956; Campbell and Robson, 1963) vision researchers have become accustomed to the merits of analysis in terms of frequency transfer…”
Channels in Vision: Basic Aspects
Braddick, O., Campbell, F. W., & Atkinson, J. (1978) · Perception · doi:10.1007/978-3-642-46354-9_1 · Cited by 231
Issues in vision modeling for perceptual video quality assessment
Winkler, S. (1999) · Signal Processing · doi:10.1016/s0165-1684(99)00062-6 · Cited by 223
Aging, senile miosis and spatial contrast sensitivity at low luminance
Sloane, M. E., Owsley, C., & Alvarez, S. L. (1988) · Vision Research · doi:10.1016/0042-6989(88)90039-9 · Cited by 202
Visual Acuity and Contrast Sensitivity in Patients with Cerebral Lesions
Bodis-Wollner, I. (1972) · Science · doi:10.1126/science.178.4062.769 · Cited by 194
Depth perception in disparity gratings
TYLER, C. W. (1974) · Nature · doi:10.1038/251140a0 · Cited by 183
Effect of Focus on the Visual Response to a Sinusoidally Modulated Spatial Stimulus*
Green, D. G., & Campbell, F. W. (1965) · Journal of the Optical Society of America · doi:10.1364/josa.55.001154 · Cited by 182
Selective depression of motion sensitivity during saccades.
Burr, D. C., Holt, J., Johnstone, J. R., & Ross, J. (1982) · The Journal of Physiology · doi:10.1113/jphysiol.1982.sp014434 · Cited by 179
Contrast sensitivity testing: A more complete assessment of vision
Jindra, L. F., & Zemon, V. (1989) · Journal of Cataract and Refractive Surgery · doi:10.1016/s0886-3350(89)80002-1 · Cited by 174
Spatial and temporal contrast sensitivity of striate cortical neurones
TOLHURST, D. J., & MOVSHON, J. A. (1975) · Nature · doi:10.1038/257674a0 · Cited by 167
The contrast sensitivity of the colour mechanisms of the human eye
Green, D. G. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008515 · Cited by 162
The Upper and Lower Visual Field of Man: Electrophysiological and Functional Differences
Skrandies, W. (1987) · Progress in Sensory Physiology · doi:10.1007/978-3-642-71060-5_1 · Cited by 159
Quality assessment of motion rendition in video coding
van den Branden Lambrecht, C. J., Costantini, D. M., Sicuranza, G. L., & Kunt, M. (1999) · IEEE Transactions on Circuits and Systems for Video Technology · doi:10.1109/76.780365 · Cited by 38
“Several researchers have addressed the problem of quality assessment of still pictures [9], [20], [ 28 ], [32], [45].”
Background
Metadata
- Authors
- Schade, O. H.
- Venue
- Journal of the Optical Society of America
- Publisher
- Optica Publishing Group
- Published
- 1956-09-01
- Volume
- 46
- Issue
- 9
- Pages
- 721
- ISSN
- 0030-3941 (ISSN-L)
- OpenAlex
- W2035989480
- Cited by
- 510
- References
- 8
- FWCI
- 1.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.