The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Image recovery from data acquired with a charge-coupled-device camera
Abstract
A model for data acquired with the use of a charge-coupled-device camera is given and is then used for developing a new iterative method for restoring intensities of objects observed with such a camera. The model includes the effects of point spread, photoconversion noise, readout noise, nonuniform flat-field response, nonuniform spectral response, and extraneous charge carriers resulting from bias, dark current, and both internal and external background radiation. An iterative algorithm is identified that produces a sequence of estimates converging toward a constrained maximum-likelihood estimate of the intensity distribution of an imaged object. An example is given for restoring images from data acquired with the use of the Hubble Space Telescope.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444
An introduction to probability theory and its applications
(1958) · Journal of the Franklin Institute · doi:10.1016/0016-0032(58)90688-4 · Cited by 29,269
Solutions of Ill-Posed Problems.
Bell, J. B., Tikhonov, A. N., & Arsenin, V. Y. (1978) · Mathematics of Computation · doi:10.2307/2006360 · Cited by 8,101
Detection, Estimation, And Modulation Theory
Trees, H. L. V. (1968) · Cited by 5,969
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Bayesian-Based Iterative Method of Image Restoration*
Richardson, W. H. (1972) · Journal of the Optical Society of America · doi:10.1364/josa.62.000055 · Cited by 4,160
An iterative technique for the rectification of observed distributions
Lucy, L. B. (1974) · The Astronomical Journal · doi:10.1086/111605 · Cited by 3,866
An Introduction to Probability Theory.
Fristedt, B., & Moran, P. A. P. (1986) · Journal of the American Statistical Association · doi:10.2307/2288022 · Cited by 3,300
On the Convergence Properties of the EM Algorithm
Wu, C. F. J. (1983) · The Annals of Statistics · doi:10.1214/aos/1176346060 · Cited by 3,269
Random Point Processes in Time and Space
Snyder, D. L., & Miller, M. I. (1991) · Springer Texts in Electrical Engineering · doi:10.1007/978-1-4612-3166-0 · Cited by 965
Self-citationA Statistical Model for Positron Emission Tomography
Vardi, Y., Shepp, L. A., & Kaufman, L. (1985) · Journal of the American Statistical Association · doi:10.1080/01621459.1985.10477119 · Cited by 863
Scientific Charge-Coupled Devices
Janesick, J. R., Elliott, T., Collins, S., Blouke, M. M., & Freeman, J. (1987) · Optical Engineering · doi:10.1117/12.7974139 · Cited by 862
Nonparametric probability density estimation
Tapia, R. A., & Thompson, J. (1978) · Cited by 454
Noise and Edge Artifacts in Maximum-Likelihood Reconstructions for Emission Tomography
Snyder, D. L., Miller, M. I., Thomas, L. J., & Politte, D. G. (1987) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1987.4307831 · Cited by 421
Self-citationThe Use of a Charge-Coupled Device for Quantitative Optical Microscopy of Biological Structures
Hiraoka, Y., Sedat, J. W., & Agard, D. A. (1987) · Science · doi:10.1126/science.3116667 · Cited by 300
The Use of Sieves to Stabilize Images Produced with the EM Algorithm for Emission Tomography
Snyder, D. L., & Miller, M. I. (1985) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1985.4334521 · Cited by 278
Self-citationDeblurring subject to nonnegativity constraints
Snyder, D. L., Schulz, T. J., & O'Sullivan, J. A. (1992) · IEEE Transactions on Signal Processing · doi:10.1109/78.134477 · Cited by 224
Self-citationPolitte, D. G., & Snyder, D. L. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.75614 · Cited by 147
Self-citationChapter 16 Solid-State Imagers for Microscopy
Aikens, R. S., Agard, D. A., & Sedat, J. W. (1988) · Methods in cell biology · doi:10.1016/s0091-679x(08)60199-5 · Cited by 116
Politte, D. G., & Snyder, D. L. (1988) · IEEE Transactions on Nuclear Science · doi:10.1109/23.12796 · Cited by 34
Self-citationModifications of the Lucy-Richardson Iteration for Restoring Hubble Space Telescope Imagery
Snyder, D. (1991) · Cited by 10
Self-citationThe HST Spherical Aberration and Its Effects on Images
White, R. L., & Burrows, C. J. (1991) · Cited by 4
Self-citation
Cited by
Deformable templates using large deformation kinematics
Christensen, G. E., Rabbitt, R. D., & Miller, M. I. (1996) · IEEE Transactions on Image Processing · doi:10.1109/83.536892 · Cited by 1,142
Localization Accuracy in Single-Molecule Microscopy
Ober, R. J., Ram, S., & Ward, E. S. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74193-4 · Cited by 587
Volumetric transformation of brain anatomy
Christensen, G. E., Joshi, S. C., & Miller, M. I. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.650882 · Cited by 438
Image deblurring with Poisson data: from cells to galaxies
Bertero, M., Boccacci, P., Desiderà, G., & Vicidomini, G. (2009) · Inverse Problems · doi:10.1088/0266-5611/25/12/123006 · Cited by 308
Metadata
- Authors
- Snyder, D. L., White, R. L., & Hammoud, A. M.
- Venue
- Journal of the Optical Society of America A
- Publisher
- Optica Publishing Group
- Published
- 1993-05-01
- Volume
- 10
- Issue
- 5
- Pages
- 1014
- ISSN
- 1084-7529 (ISSN-L)
- 1520-8532
- OpenAlex
- W2165437406
- Cited by
- 318
- References
- 22
- FWCI
- 16.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.