The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
The Rose model, revisited
Abstract
In 1946 and 1948, three very important papers by Albert Rose [J. Soc. Motion Pict. Eng. 47, 273 (1946); J. Opt. Soc. Am. 38, 196 (1948); L. Marton, ed. (Academic, New York, 1948)] were published on the role that photon fluctuations have in setting fundamental performance limits for both human vision and electronic imaging systems. The papers were important because Rose demonstrated that the performance of imaging devices can be evaluated with an absolute scale (quantum efficiency). The analysis of human visual signal detection used in these papers (developed before the formal theory of signal detectability) was based on an approach that has come to be known as the Rose model. In spite of its simplicity, the Rose model is a very good approximation of a Bayesian ideal observer for the carefully and narrowly defined conditions that Rose considered. This simple model can be used effectively for back-of-the-envelope calculations, but it needs to be used with care because of its limited range of validity. One important conclusion arising from Rose's investigations is that pixel signal-to-noise ratio is not a good figure of merit for imaging systems or components, even though it is still occasionally used as such by some researchers. In the present study, (1) aspects of signal detection theory are presented, (2) Rose's model is described and discussed, (3) pixel signal-to-noise ratio is discussed, and (4) progress on modeling human noise-limited performance is summarized. This study is intended to be a tutorial with presentation of the main ideas and provision of references to the (dispersed) technical literature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Probability, Random Variables, and Stochastic Processes.
Abrahams, J., & Papoulis, A. (1984) · Journal of the American Statistical Association · doi:10.2307/2288754 · Cited by 16,226
Introduction to Statistical Pattern Recognition
(1990) · Elsevier eBooks · doi:10.1016/c2009-0-27872-x · Cited by 11,031
Statistical Methods for Research Workers
(1945) · American Journal of Clinical Pathology · doi:10.1093/ajcp/15.11.552b · Cited by 10,880
(1966) · Medical Entomology and Zoology · Cited by 10,293
An Introduction to Multivariate Statistical Analysis
Muirhead, R. J., & Anderson, T. W. (1986) · Journal of Business & Economic Statistics · doi:10.2307/1391399 · Cited by 9,082
Random Data-Analysis and Measurement Procedures
Bendat, J. S., Piersol, A. G., & Saunders, H. (1989) · Journal of Vibration and Acoustics · doi:10.1115/1.3269865 · Cited by 6,375
Detection, Estimation, And Modulation Theory
Trees, H. L. V. (1968) · Cited by 5,969
Detection Theory: A User's Guide
Macmillan, N. A., & Creelman, C. D. (1991) · Cited by 5,415
Extrapolation, Interpolation, and Smoothing of Stationary Time Series: With Engineering Applications
Wiener, N. (1949) · The MIT Press eBooks · doi:10.7551/mitpress/2946.001.0001 · Cited by 4,826
IX. On the problem of the most efficient tests of statistical hypotheses
Neyman, J., & Pearson, E. S. (1933) · Philosophical Transactions of the Royal Society of London. Series A, Containing Papers of a Mathematical or Physical Character · doi:10.1098/rsta.1933.0009 · Cited by 2,341
Advances in Electronics and Electron Physics
Marton, L., & Sproull, R. L. (1960) · Physics Today · doi:10.1063/1.3056875 · Cited by 1,828
ROC Methodology in Radiologic Imaging
METZ, C. E. (1986) · Investigative Radiology · doi:10.1097/00004424-198609000-00009 · Cited by 1,642
ON THE PROBLEM OF THE MOST EFFICIENT TESTS OF STATISTICAL HYPOTHESES
(1967) · Joint Statistical Papers · doi:10.1525/9780520339897-008 · Cited by 1,504
The Sensitivity Performance of the Human Eye on an Absolute Scale*
Rose, A. (1948) · Journal of the Optical Society of America · doi:10.1364/josa.38.000196 · Cited by 931
The theory of signal detectability
Peterson, W., Birdsall, T., & Fox, W. (1954) · Transactions of the IRE Professional Group on Information Theory · doi:10.1109/tit.1954.1057460 · Cited by 867
Some Practical Issues of Experimental Design and Data Analysis in Radiological ROC Studies
METZ, C. E. (1989) · Investigative Radiology · doi:10.1097/00004424-198903000-00012 · Cited by 859
Uncertainty explains many aspects of visual contrast detection and discrimination
Pelli, D. G. (1985) · Journal of the Optical Society of America A · doi:10.1364/josaa.2.001508 · Cited by 670
Digital images and human vision
(1994) · Choice Reviews Online · doi:10.5860/choice.31-5492 · Cited by 656
Model observers for assessment of image quality.
Barrett, H. H., Yao, J., Rolland, J. P., & Myers, K. J. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.21.9758 · Cited by 531
Signal detection and recognition by human observers : contemporary readings
Swets, J. A. (1964) · Wiley eBooks · Cited by 446
Efficiency of Human Visual Signal Discrimination
Burgess, A. E., Wagner, R. F., Jennings, R. J., & Barlow, H. B. (1981) · Science · doi:10.1126/science.7280685 · Cited by 411
Self-citationAddition of a channel mechanism to the ideal-observer model
Myers, K. J., & Barrett, H. H. (1987) · Journal of the Optical Society of America A · doi:10.1364/josaa.4.002447 · Cited by 400
Objective assessment of image quality: effects of quantum noise and object variability
Barrett, H. H. (1990) · Journal of the Optical Society of America A · doi:10.1364/josaa.7.001266 · Cited by 380
Rose, A., & Biberman, L. (1975) · Physics Today · doi:10.1063/1.3069240 · Cited by 378
de Vries, H. L. (1943) · Physica · doi:10.1016/s0031-8914(43)90575-0 · Cited by 363
Visual signal detection IV Observer inconsistency
Burgess, A. E., & Colborne, B. (1988) · Journal of the Optical Society of America A · doi:10.1364/josaa.5.000617 · Cited by 282
Self-citationEffect of random background inhomogeneity on observer detection performance
Rolland, J. P., & Barrett, H. H. (1992) · Journal of the Optical Society of America A · doi:10.1364/josaa.9.000649 · Cited by 272
Barrett, H. H., Abbey, C. K., & Clarkson, E. W. (1998) · Journal of the Optical Society of America A · doi:10.1364/josaa.15.001520 · Cited by 248
Barrett, H. H., Denny, J. L., Wagner, R. F., & Myers, K. J. (1995) · Journal of the Optical Society of America A · doi:10.1364/josaa.12.000834 · Cited by 243
Definitions of d′ and η as Psychophysical Measures
Tanner, W. P., & Birdsall, T. G. (1958) · The Journal of the Acoustical Society of America · doi:10.1121/1.1909408 · Cited by 241
The quantum efficiency of vision
Pelli, D. G. (1991) · Vision · doi:10.1017/cbo9780511626197.003 · Cited by 233
Effect of noise correlation on detectability of disk signals in medical imaging
Myers, K. J., Barrett, H. H., Borgstrom, M. C., Patton, D. D., & Seeley, G. W. (1985) · Journal of the Optical Society of America A · doi:10.1364/josaa.2.001752 · Cited by 205
The efficiency of detecting changes of density in random dot patterns
Barlow, H. B. (1978) · Vision Research · doi:10.1016/0042-6989(78)90143-8 · Cited by 176
Human efficiency for recognizing 3-D objects in luminance noise
Tjan, B. S., Braje, W. L., Legge, G. E., & Kersten, D. (1995) · Vision Research · doi:10.1016/0042-6989(95)00070-g · Cited by 156
Retinal inhomogeneity I Spatiotemporal contrast sensitivity
Kelly, D. H. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000107 · Cited by 149
Visual signal detection II Signal-location identification
Burgess, A. E., & Ghandeharian, H. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000906 · Cited by 148
Self-citationRose, A. (1946) · Journal of the Society of Motion Picture Engineers · doi:10.5594/j12772 · Cited by 143
The Relative Sensitivities of Television Pickup Tubes, Photographic Film, and the Human Eye
Rose, A. (1942) · Proceedings of the IRE · doi:10.1109/jrproc.1942.230998 · Cited by 113
Visual signal detection I Ability to use phase information
Burgess, A. E., & Ghandeharian, H. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000900 · Cited by 102
Self-citationModern statistical approaches to reception in communication theory
Meter, D. V., & Middleton, D. (1954) · Transactions of the IRE Professional Group on Information Theory · doi:10.1109/tit.1954.1057471 · Cited by 95
Modelling contrast sensitivity as a function of retinal illuminance and grating area
Rovamo, J. M., Mustonen, J., & Näsänen, R. (1994) · Vision Research · doi:10.1016/0042-6989(94)90204-6 · Cited by 90
Toward a unified view of radiological imaging systems. Part II: Noisy images
Wagner, R. F. (1977) · Medical Physics · doi:10.1118/1.594362 · Cited by 86
Spatial summation in visual noise
Kersten, D. (1984) · Vision Research · doi:10.1016/0042-6989(84)90033-6 · Cited by 83
Visual signal detectionIIIOn Bayesian use of prior knowledge and cross correlation
Burgess, A. E. (1985) · Journal of the Optical Society of America A · doi:10.1364/josaa.2.001498 · Cited by 75
Self-citationToward a unified view of radiological imaging systems: Part I: Noiseless Images
Wagner, R. F., Weaver, K. E., Denny, E. W., & Bostrom, R. G. (1974) · Medical Physics · doi:10.1118/1.1637272 · Cited by 65
The Quantum Relations of Vision*
Hecht, S. (1942) · Journal of the Optical Society of America · doi:10.1364/josa.32.000042 · Cited by 51
Role of knowledge in human visual temporal integration in spatiotemporal noise
Eckstein, M. P., Whiting, J. S., & Thomas, J. P. (1996) · Journal of the Optical Society of America A · doi:10.1364/josaa.13.001960 · Cited by 37
Model for perception of pulsed fluoroscopy image sequences
Aufrichtig, R., Thomas, C. W., Xue, P., & Wilson, D. L. (1994) · Journal of the Optical Society of America A · doi:10.1364/josaa.11.003167 · Cited by 29
Cited by
Optical coherence tomography angiography
Spaide, R. F., Fujimoto, J. G., Waheed, N. K., Sadda, S. R., & Staurenghi, G. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.11.003 · Cited by 1,779
Dedicated Breast CT: Radiation Dose and Image Quality Evaluation
Boone, J. M., Nelson, T. R., Lindfors, K. K., & Seibert, J. A. (2001) · Radiology · doi:10.1148/radiol.2213010334 · Cited by 468
Abbey, C. K., & Barrett, H. H. (2001) · Journal of the Optical Society of America A · doi:10.1364/josaa.18.000473 · Cited by 324
Pelli, D. G., & Farell, B. (1999) · Journal of the Optical Society of America A · doi:10.1364/josaa.16.000647 · Cited by 275
Xanthene-Based NIR-II Dyes for In Vivo Dynamic Imaging of Blood Circulation
Liu, D., He, Z., Zhao, Y., Yang, Y., Shi, W., Li, X., & Ma, H. (2021) · Journal of the American Chemical Society · doi:10.1021/jacs.1c07711 · Cited by 217
Metadata
- Authors
- Burgess, A. E.
- Venue
- Journal of the Optical Society of America A
- Publisher
- Optica Publishing Group
- Published
- 1999-03-01
- Volume
- 16
- Issue
- 3
- Pages
- 633
- ISSN
- 1084-7529 (ISSN-L)
- 1520-8532
- OpenAlex
- W2130004040
- Cited by
- 260
- References
- 48
- FWCI
- 1.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.