The DOI matches its Crossref record.
Properties of a 4Pi confocal fluorescence microscope
Abstract
In a 4Pi confocal fluorescence microscope two opposing microscope objective lenses were used to illuminate a fluorescent object from both sides and to collect the fluorescence emissions on both sides. Constructive interference of either the illumination wave fronts in the common focus or the detection wave fronts in the common detector pinhole resulted in an axial resolution approximately four times higher than that in a confocal fluorescence microscope. A precise 4Pi confocal fluorescence microscope that uses simultaneous illumination was built. The full width at half-maximum of the depth discrimination was determined experimentally to be approximately 110 nm when lenses with a numerical aperture of 1.4, an excitation of 633 nm, and detection of approximately 725 nm were used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The third dimension bridges the gap between cell culture and live tissue
Pampaloni, F., Reynaud, E. G., & Stelzer, E. H. K. (2007) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2236 · Cited by 2,817
Self-citationFluorescence nanoscopy in cell biology
Sahl, S. J., Hell, S. W., & Jakobs, S. (2017) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm.2017.71 · Cited by 990
Self-citationVideo-Rate Far-Field Optical Nanoscopy Dissects Synaptic Vesicle Movement
Westphal, V., Rizzoli, S. O., Lauterbach, M. A., Kamin, D., Jahn, R., & Hell, S. W. (2008) · Science · doi:10.1126/science.1154228 · Cited by 788
Self-citationI5M: 3D widefield light microscopy with better than 100 nm axial resolution
Gustafsson, Agard, & Sedat (1999) · Journal of Microscopy · doi:10.1046/j.1365-2818.1999.00576.x · Cited by 417
Nanometer-localized multiple single-molecule fluorescence microscopy
Qu, X., Wu, D., Mets, L., & Scherer, N. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402155101 · Cited by 304
Metadata
- Authors
- Hell, S., & Stelzer, E. H. K.
- Venue
- Journal of the Optical Society of America A
- Publisher
- Optica Publishing Group
- Published
- 1992-12-01
- Volume
- 9
- Issue
- 12
- Pages
- 2159
- ISSN
- 1084-7529 (ISSN-L)
- 1520-8532
- OpenAlex
- W2141802984
- Cited by
- 560
- References
- 0
- FWCI
- 6.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Properties of a 4Pi confocal fluorescence microscope. https://app.cochat.ai/papers/10.1364/josaa.9.002159
- The paper
- Hell, S., & Stelzer, E. H. K. (1992). Properties of a 4Pi confocal fluorescence microscope. Journal of the Optical Society of America A. https://doi.org/10.1364/josaa.9.002159
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.