The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Properties of a 4Pi confocal fluorescence microscope
Abstract
In a 4Pi confocal fluorescence microscope two opposing microscope objective lenses were used to illuminate a fluorescent object from both sides and to collect the fluorescence emissions on both sides. Constructive interference of either the illumination wave fronts in the common focus or the detection wave fronts in the common detector pinhole resulted in an axial resolution approximately four times higher than that in a confocal fluorescence microscope. A precise 4Pi confocal fluorescence microscope that uses simultaneous illumination was built. The full width at half-maximum of the depth discrimination was determined experimentally to be approximately 110 nm when lenses with a numerical aperture of 1.4, an excitation of 633 nm, and detection of approximately 725 nm were used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488
Richards, B., & Wolf, E. (1959) · Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences · doi:10.1098/rspa.1959.0200 · Cited by 3,095
Electromagnetic diffraction in optical systems - I. An integral representation of the image field
Wolf, E. (1959) · Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences · doi:10.1098/rspa.1959.0199 · Cited by 789
Hell, S., & Stelzer, E. H. K. (1992) · Optics Communications · doi:10.1016/0030-4018(92)90185-t · Cited by 415
Self-citationImaging in high-aperture optical systems
Sheppard, C. J. R., & Matthews, H. J. (1987) · Journal of the Optical Society of America A · doi:10.1364/josaa.4.001354 · Cited by 184
Optical sectioning in confocal fluorescent microscopes
Wilson, T. (1989) · Journal of Microscopy · doi:10.1111/j.1365-2818.1989.tb00577.x · Cited by 137
Energy Flow in the Neighborhood of the Focus of a Coherent Beam*
Boivin, A., Dow, J., & Wolf, E. (1967) · Journal of the Optical Society of America · doi:10.1364/josa.57.001171 · Cited by 121
3‐D image formation in high‐aperture fluorescence confocal microscopy: a numerical analysis
van der Voort, H. T. M., & Brakenhoff, G. J. (1990) · Journal of Microscopy · doi:10.1111/j.1365-2818.1990.tb02975.x · Cited by 119
Cited by
Ultra-High Resolution Imaging by Fluorescence Photoactivation Localization Microscopy
Hess, S. T., Girirajan, T. P. K., & Mason, M. D. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.091116 · Cited by 3,605
The third dimension bridges the gap between cell culture and live tissue
Pampaloni, F., Reynaud, E. G., & Stelzer, E. H. K. (2007) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2236 · Cited by 2,817
Self-citationGustafsson, M. G. L. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406877102 · Cited by 2,224
Hell, S. W. (2003) · Nature Biotechnology · doi:10.1038/nbt895 · Cited by 1,003
Self-citationFluorescence nanoscopy in cell biology
Sahl, S. J., Hell, S. W., & Jakobs, S. (2017) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm.2017.71 · Cited by 990
Self-citationVideo-Rate Far-Field Optical Nanoscopy Dissects Synaptic Vesicle Movement
Westphal, V., Rizzoli, S. O., Lauterbach, M. A., Kamin, D., Jahn, R., & Hell, S. W. (2008) · Science · doi:10.1126/science.1154228 · Cited by 788
Self-citationOptical trapping with structured light: a review
Yang, Y., Ren, Y.-X., Chen, M., Arita, Y., & Rosales-Guzmán, C. (2021) · Advanced Photonics · doi:10.1117/1.ap.3.3.034001 · Cited by 776
Hair cell synaptic ribbons are essential for synchronous auditory signalling
Khimich, D., Nouvian, R., Pujol, R., tom Dieck, S., Egner, A., Gundelfinger, E. D., & Moser, T. (2005) · Nature · doi:10.1038/nature03418 · Cited by 583
A review of complex vector light fields and their applications
Rosales-Guzmán, C., Ndagano, B., & Forbes, A. (2018) · Journal of Optics · doi:10.1088/2040-8986/aaeb7d · Cited by 509
von Diezmann, L., Shechtman, Y., & Moerner, W. E. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00629 · Cited by 491
I5M: 3D widefield light microscopy with better than 100 nm axial resolution
Gustafsson, Agard, & Sedat (1999) · Journal of Microscopy · doi:10.1046/j.1365-2818.1999.00576.x · Cited by 417
Tuning of synapse number, structure and function in the cochlea
Meyer, A. C., Frank, T., Khimich, D., Hoch, G., Riedel, D., Chapochnikov, N. M., Yarin, Y. M., Harke, B., Hell, S. W., Egner, A., et al. (2009) · Nature Neuroscience · doi:10.1038/nn.2293 · Cited by 363
Self-citationStimulated Emission Depletion Microscopy
Blom, H., & Widengren, J. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00653 · Cited by 339
Light sheet fluorescence microscopy
Stelzer, E. H. K., Strobl, F., Chang, B.-J., Preusser, F., Preibisch, S., McDole, K., & Fiolka, R. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00069-4 · Cited by 334
Self-citationLight-sheet fluorescence microscopy for quantitative biology
Stelzer, E. H. K. (2015) · Nature Methods · doi:10.1038/nmeth.3219 · Cited by 325
Self-citationEnhancement of axial resolution in fluorescence microscopy by standing-wave excitation
Bailey, B., Farkas, D. L., Taylor, D. L., & Lanni, F. (1993) · Nature · doi:10.1038/366044a0 · Cited by 324
Yuste, R. (2005) · Nature Methods · doi:10.1038/nmeth1205-902 · Cited by 315
Egner, A., Jakobs, S., & Hell, S. W. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.052545099 · Cited by 313
Self-citationNanometer-localized multiple single-molecule fluorescence microscopy
Qu, X., Wu, D., Mets, L., & Scherer, N. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402155101 · Cited by 304
Dynamics in the plasma membrane: how to combine fluidity and order
Marguet, D., Lenne, P., Rigneault, H., & He, H. (2006) · The EMBO Journal · doi:10.1038/sj.emboj.7601204 · Cited by 288
Concepts for nanoscale resolution in fluorescence microscopy
Hell, S. W., Dyba, M., & Jakobs, S. (2004) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2004.08.015 · Cited by 288
Self-citationUltrahigh-resolution multicolor colocalization of single fluorescent probes
Lacoste, T. D., Michalet, X., Pinaud, F., Chemla, D. S., Alivisatos, A. P., & Weiss, S. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.170286097 · Cited by 285
Advances in Light Microscopy for Neuroscience
Wilt, B. A., Burns, L. D., Wei Ho, E. T., Ghosh, K. K., Mukamel, E. A., & Schnitzer, M. J. (2009) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.051508.135540 · Cited by 278
Beyond Rayleigh's criterion: A resolution measure with application to single-molecule microscopy
Ram, S., Ward, E. S., & Ober, R. J. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0508047103 · Cited by 259
Aquino, D., Schönle, A., Geisler, C., Middendorff, C. V., Wurm, C. A., Okamura, Y., Lang, T., Hell, S. W., & Egner, A. (2011) · Nature Methods · doi:10.1038/nmeth.1583 · Cited by 254
Self-citationSaffarian, S., & Kirchhausen, T. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.117234 · Cited by 111
Metadata
- Authors
- Hell, S., & Stelzer, E. H. K.
- Venue
- Journal of the Optical Society of America A
- Publisher
- Optica Publishing Group
- Published
- 1992-12-01
- Volume
- 9
- Issue
- 12
- Pages
- 2159
- ISSN
- 1084-7529 (ISSN-L)
- 1520-8532
- OpenAlex
- W2141802984
- Cited by
- 560
- References
- 8
- FWCI
- 6.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.