The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Polarization effect on position accuracy of fluorophore localization
Open accessAbstract
The technique of determining the position of individual fluorescent molecules with nanometer resolution, called FIONA, has become an important tool for several biophysical applications such as studying motility mechanisms of motor proteins. The position determination is usually done by fitting a 2-D Gaussian (x-y vs. photon number) to the emission intensity distribution of the fluorescent molecule. However, the intensity distribution of an emitting molecule depends not only on its position in space, but also on its three-dimensional orientation. Here, we present an extensive numeri-cal study of the achievable accuracy of position determination as a function of molecule orientation. We compare objectives with different numerical apertures and show that an effective pixel size of 100 nm or less per CCD pixel is required to obtain good positional accuracy. Nonetheless, orienta-tion effects can still cause position errors for large anisotropy, as high as 10 nm for high numerical aperture objectives. However, position accuracy is significantly better (< 2.5 nm) when using objectives with a numerical aper-ture of 1.2. Of course, probes with lower anisotropy decrease the positional uncertainty.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Precise Nanometer Localization Analysis for Individual Fluorescent Probes
Thompson, R. E., Larson, D. R., & Webb, W. W. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75618-x · Cited by 2,320
Cited by
Super-resolution fluorescence microscopy
Huang, B., Bates, M., & Zhuang, X. (2009) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.77.061906.092014 · Cited by 1,657
Fast, single-molecule localization that achieves theoretically minimum uncertainty
Smith, C. S., Joseph, N., Rieger, B., & Lidke, K. A. (2010) · Nature Methods · doi:10.1038/nmeth.1449 · Cited by 522
Stimulated Emission Depletion Microscopy
Blom, H., & Widengren, J. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00653 · Cited by 339
Switchable Fluorophores for Single-Molecule Localization Microscopy
Li, H., & Vaughan, J. C. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00767 · Cited by 319
Single-molecule spectroscopy and imaging over the decades
Moerner, W. E., Shechtman, Y., & Wang, Q. (2015) · Faraday Discussions · doi:10.1039/c5fd00149h · Cited by 103
Metadata
- Authors
- Enderlein, J., Toprak, E., & Selvin, P. R.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2006
- Volume
- 14
- Issue
- 18
- Pages
- 8111
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2027220406
- Cited by
- 195
- References
- 1
- FWCI
- 3.57
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Polarization effect on position accuracy of fluorophore localization. https://app.cochat.ai/papers/10.1364/oe.14.008111
- The paper
- Enderlein, J., Toprak, E., & Selvin, P. R. (2006). Polarization effect on position accuracy of fluorophore localization. Optics Express. https://doi.org/10.1364/oe.14.008111
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.