Experimental characterization of 3D localization techniques for particle-tracking and super-resolution microscopy
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Three-dimensional (3D) particle localization at the nanometer scale plays a central role in 3D particle tracking and 3D localization-based super-resolution microscopy. Here we introduce a localization algorithm that is independent of theoretical models and therefore generally applicable to a large number of experimental realizations. Applying this algorithm and a convertible experimental setup we compare the performance of the two major 3D techniques based on astigmatic distortions and on multiplane detection. In both methods we obtain experimental 3D localization accuracies in agreement with theoretical predictions and characterize the depth dependence of the localization accuracy in detail.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967
Prabhat, P., Gan, Z., Chao, J., Ram, S., Vaccaro, C., Gibbons, S., Ober, R. J., & Ward, E. S. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0700337104 · Cited by 157
Cited by
A review of progress in single particle tracking: from methods to biophysical insights
Manzo, C., & Garcia-Parajo, M. F. (2015) · Reports on Progress in Physics · doi:10.1088/0034-4885/78/12/124601 · Cited by 597
Fast, single-molecule localization that achieves theoretically minimum uncertainty
Smith, C. S., Joseph, N., Rieger, B., & Lidke, K. A. (2010) · Nature Methods · doi:10.1038/nmeth.1449 · Cited by 522
Precisely and accurately localizing single emitters in fluorescence microscopy
Deschout, H., Zanacchi, F. C., Mlodzianoski, M., Diaspro, A., Bewersdorf, J., Hess, S. T., & Braeckmans, K. (2014) · Nature Methods · doi:10.1038/nmeth.2843 · Cited by 498
Self-citationvon Diezmann, L., Shechtman, Y., & Moerner, W. E. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00629 · Cited by 491
Cierpka, C., & Kähler, C. J. (2012) · Journal of Visualization · doi:10.1007/s12650-011-0107-9 · Cited by 450
Optimal Point Spread Function Design for 3D Imaging
Shechtman, Y., Sahl, S. J., Backer, A. S., & Moerner, W. E. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.133902 · Cited by 384
Fluorophore localization algorithms for super-resolution microscopy
Small, A., & Stahlheber, S. (2014) · Nature Methods · doi:10.1038/nmeth.2844 · Cited by 349
A New Wave of Cellular Imaging
Toomre, D., & Bewersdorf, J. (2010) · Annual Review of Cell and Developmental Biology · doi:10.1146/annurev-cellbio-100109-104048 · Cited by 319
Self-citationOrtega-Arroyo, J., & Kukura, P. (2012) · Physical Chemistry Chemical Physics · doi:10.1039/c2cp41013c · Cited by 293
Walking along chromosomes with super-resolution imaging, contact maps, and integrative modeling
Nir, G., Farabella, I., Pérez Estrada, C., Ebeling, C. G., Beliveau, B. J., Sasaki, H. M., Lee, S. D., Nguyen, S. C., McCole, R. B., Chattoraj, S., et al. (2018) · PLOS Genetics · doi:10.1371/journal.pgen.1007872 · Cited by 261
Review of digital holographic microscopy for three-dimensional profiling and tracking
Yu, X., Hong, J., Liu, C., & Kim, M. K. (2014) · Optical Engineering · doi:10.1117/1.oe.53.11.112306 · Cited by 187
Sample drift correction in 3D fluorescence photoactivation localization microscopy
Mlodzianoski, M. J., Schreiner, J. M., Callahan, S. P., Smolková, K., Dlasková, A., Šantorová, J., Ježek, P., & Bewersdorf, J. (2011) · Optics Express · doi:10.1364/oe.19.015009 · Cited by 185
Self-citationThompson, M. A., Lew, M. D., Badieirostami, M., & Moerner, W. E. (2010) · Nano Letters · doi:10.1021/nl903295p · Cited by 184
York, A. G., Ghitani, A., Vaziri, A., Davidson, M. W., & Shroff, H. (2011) · Nature Methods · doi:10.1038/nmeth.1571 · Cited by 172
“An alternate strategy for 3D pointillist super-resolution combines wide-field illumination of bright, exogenously introduced dyes with 3D subdiffractive localization technique”
BackgroundBaddeley, D., Crossman, D., Rossberger, S., Cheyne, J. E., Montgomery, J. M., Jayasinghe, I. D., Cremer, C., Cannell, M. B., & Soeller, C. (2011) · PLoS ONE · doi:10.1371/journal.pone.0020645 · Cited by 167
“It has been shown that such an oversized PSF estimate results in only a minor degradation in the precision of single molecule localisation [33], an effect which is likely to be offset by the improved signal to noise obtained by using larger beads.”
BackgroundMethodDirect optical nanoscopy with axially localized detection
Bourg, N., Mayet, C., Dupuis, G., Barroca, T., Bon, P., Lécart, S., Fort, E., & Lévêque-Fort, S. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.132 · Cited by 163
Akiyama, H., Ramirez, N.-G. P., Gudheti, M. V., & Gummuluru, S. (2015) · PLOS Pathogens · doi:10.1371/journal.ppat.1004751 · Cited by 79
“We used a fluorescence photoactivation localization microscopy (FPALM) with bi-plane capture technique [35–37] which allowed us to visualize CD169 VCCs in mature DCs at 20–40 nm (X-Y) and 50–80 nm (Z) resolution.”
Method
Metadata
- Authors
- Mlodzianoski, M. J., Juette, M. F., Beane, G. L., & Bewersdorf, J.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2009-04-30
- Volume
- 17
- Issue
- 10
- Pages
- 8264
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W1989823848
- Cited by
- 136
- References
- 2
- FWCI
- 6.94
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.