Optical referencing technique with CW lasers as intermediate oscillators for continuous full delay range frequency comb interferometry
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This paper presents a significant advancement in the referencing technique applied to frequency comb spectrometry (cFTS) that we proposed and demonstrated recently. Based on intermediate laser oscillators, it becomes possible to access the full delay range set by the repetition rate of the frequency combs, overcoming the principal limitation observed in the method based on passive optical filters. With this new referencing technique, the maximum spectral resolution given by each comb tooth is achievable and continuous scanning will improve complex reflectometry measurements. We present a demonstration of such a high resolution cFTS system, providing a spectrometry measurement at 100 MHz of resolution (0.003 cm(-1)) with a spectral signal to noise ratio of 440 for a 2 seconds measurement time. The resulting spectrum is composed of 105 · 10(3) resolved spectral elements, each corresponding to a single pair of optical modes (one for each combs). To our knowledge, this represents the first cFTS measurement over the full spectral range of the sources in a single shot with resolved individual modes at full resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Time-domain mid-infrared frequency-comb spectrometer
Keilmann, F., Gohle, C., & Holzwarth, R. (2004) · Optics Letters · doi:10.1364/ol.29.001542 · Cited by 734
Coherent linear optical sampling at 15 bits of resolution
Coddington, I., Swann, W. C., & Newbury, N. R. (2009) · Optics Letters · doi:10.1364/ol.34.002153 · Cited by 120
High-resolution THz spectrometer with kHz scan rates
Bartels, A., Thoma, A., Janke, C., Dekorsy, T., Dreyhaupt, A., Winnerl, S., & Helm, M. (2006) · Optics Express · doi:10.1364/opex.14.000430 · Cited by 88
Cited by
Coddington, I., Newbury, N., & Swann, W. (2016) · Optica · doi:10.1364/optica.3.000414 · Cited by 1,754
“If this dynamic range is set by the rf amplification of the strong centerburst (rather than intrinsic nonlinearity in the photodetection), the peak signal intensity can be reduced by strongly chirping one of the two frequency combs [17].”
Influential20 years of developments in optical frequency comb technology and applications
Fortier, T., & Baumann, E. (2019) · Communications Physics · doi:10.1038/s42005-019-0249-y · Cited by 963
Searching for applications with a fine-tooth comb
Newbury, N. R. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.38 · Cited by 453
Adaptive real-time dual-comb spectroscopy
Ideguchi, T., Poisson, A., Guelachvili, G., Picqué, N., & Hänsch, T. W. (2014) · Nature Communications · doi:10.1038/ncomms4375 · Cited by 434
“imultaneously with accuracy and sensitivity. Recently, the precisely spaced spectral lines of a laser frequency comb have been harnessed for new techniques of dual-comb Fourier transform spectroscopy [8, 9, 10, 11, 12, 13, 14, 15, 16]. Due to interference between pairs of optical comb lines, the optical spectrum is ef…”
BackgroundMethodHigh-coherence mid-infrared dual-comb spectroscopy spanning 2.6 to 5.2 μm
Ycas, G., Giorgetta, F. R., Baumann, E., Coddington, I., Herman, D., Diddams, S. A., & Newbury, N. R. (2018) · Nature Photonics · doi:10.1038/s41566-018-0114-7 · Cited by 349
Metadata
- Authors
- Deschênes, J.-D., Giaccarri, P., & Genest, J.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2010-10-20
- Volume
- 18
- Issue
- 22
- Pages
- 23358
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2041753428
- Cited by
- 140
- References
- 3
- FWCI
- 6.38
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical referencing technique with CW lasers as intermediate oscillators for continuous full delay range frequency comb interferometry. https://app.cochat.ai/papers/10.1364/oe.18.023358
- The paper
- Deschênes, J.-D., Giaccarri, P., & Genest, J. (2010). Optical referencing technique with CW lasers as intermediate oscillators for continuous full delay range frequency comb interferometry. Optics Express. https://doi.org/10.1364/oe.18.023358
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.