The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Picometer-resolution dual-comb spectroscopy with a free-running fiber laser
Open accessAbstract
Dual-comb spectroscopy holds the promise as real-time, high-resolution spectroscopy tools. However, in its conventional schemes, the stringent requirement on the coherence between two lasers requires sophisticated control systems. By replacing control electronics with an all-optical dual-comb lasing scheme, a simplified dual-comb spectroscopy scheme is demonstrated using one dual-wavelength, passively mode-locked fiber laser. Pulses with a intracavity-dispersion-determined repetition-frequency difference are shown to have good mutual coherence and stability. Capability to resolve the comb teeth and a picometer-wide optical spectral resolution are demonstrated using a simple data acquisition system. Energy-efficient, free-running fiber lasers with a small comb-tooth-spacing could enable low-cost dual-comb systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Udem, T., Holzwarth, R., & Hänsch, T. W. (2002) · Nature · doi:10.1038/416233a · Cited by 3,111
Microresonator-Based Optical Frequency Combs
Kippenberg, T. J., Holzwarth, R., & Diddams, S. A. (2011) · Science · doi:10.1126/science.1193968 · Cited by 2,192
Coddington, I., Newbury, N., & Swann, W. (2016) · Optica · doi:10.1364/optica.3.000414 · Cited by 1,754
Rapid and precise absolute distance measurements at long range
Coddington, I., Swann, W. C., Nenadovic, L., & Newbury, N. R. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.94 · Cited by 1,059
Nobel Lecture: Passion for precision
Hänsch, T. W. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1297 · Cited by 915
Time-domain mid-infrared frequency-comb spectrometer
Keilmann, F., Gohle, C., & Holzwarth, R. (2004) · Optics Letters · doi:10.1364/ol.29.001542 · Cited by 734
Cavity-enhanced dual-comb spectroscopy
Bernhardt, B., Ozawa, A., Jacquet, P., Jacquey, M., Kobayashi, Y., Udem, T., Holzwarth, R., Guelachvili, G., Hänsch, T. W., & Picqué, N. (2010) · Nature Photonics · doi:10.1038/nphoton.2009.217 · Cited by 594
Spectral line-by-line pulse shaping of on-chip microresonator frequency combs
Ferdous, F., Miao, H., Leaird, D. E., Srinivasan, K., Wang, J., Chen, L., Varghese, L. T., & Weiner, A. M. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.255 · Cited by 508
Direct frequency comb spectroscopy in the extreme ultraviolet
Cingöz, A., Yost, D. C., Allison, T. K., Ruehl, A., Fermann, M. E., Hartl, I., & Ye, J. (2012) · Nature · doi:10.1038/nature10711 · Cited by 477
Ultrafast time-domain spectroscopy based on high-speed asynchronous optical sampling
Bartels, A., Cerna, R., Kistner, C., Thoma, A., Hudert, F., Janke, C., & Dekorsy, T. (2007) · Review of Scientific Instruments · doi:10.1063/1.2714048 · Cited by 460
Adaptive real-time dual-comb spectroscopy
Ideguchi, T., Poisson, A., Guelachvili, G., Picqué, N., & Hänsch, T. W. (2014) · Nature Communications · doi:10.1038/ncomms4375 · Cited by 434
Frequency-agile dual-comb spectroscopy
Millot, G., Pitois, S., Yan, M., Hovhannisyan, T., Bendahmane, A., Hänsch, T. W., & Picqué, N. (2016) · Nature Photonics · doi:10.1038/nphoton.2015.250 · Cited by 423
Frequency-comb-based remote sensing of greenhouse gases over kilometer air paths
Rieker, G. B., Giorgetta, F. R., Swann, W. C., Kofler, J., Zolot, A. M., Sinclair, L. C., Baumann, E., Cromer, C., Petron, G., Sweeney, C., et al. (2014) · Optica · doi:10.1364/optica.1.000290 · Cited by 409
Frequency-comb infrared spectrometer for rapid, remote chemical sensing
Schliesser, A., Brehm, M., Keilmann, F., & van der Weide, D. W. (2005) · Optics Express · doi:10.1364/opex.13.009029 · Cited by 384
Phase-locked, erbium-fiber-laser-based frequency comb in the near infrared
Washburn, B. R., Diddams, S. A., Newbury, N. R., Nicholson, J. W., Yan, M. F., & Jørgensen, C. G. (2004) · Optics Letters · doi:10.1364/ol.29.000250 · Cited by 382
Coherent dual-comb spectroscopy at high signal-to-noise ratio
Coddington, I., Swann, W., & Newbury, N. (2010) · Physical Review A · doi:10.1103/physreva.82.043817 · Cited by 322 · cited 1×
“A programmable spectral filter is used to control the bandwidth of the 1544 nm pulse incident onto the detector, in order to avoid frequency aliasing [10].”
MethodHigh confinement micron-scale silicon nitride high Q ring resonator
Gondarenko, A., Levy, J. S., & Lipson, M. (2009) · Optics Express · doi:10.1364/oe.17.011366 · Cited by 320
Sensitivity of coherent dual-comb spectroscopy
Newbury, N. R., Coddington, I., & Swann, W. (2010) · Optics Express · doi:10.1364/oe.18.007929 · Cited by 283
Mid-infrared Fourier transform spectroscopy with a broadband frequency comb
Adler, F., Masłowski, P., Foltynowicz, A., Cossel, K. C., Briles, T. C., Hartl, I., & Ye, J. (2010) · Optics Express · doi:10.1364/oe.18.021861 · Cited by 274
Spectroscopy of the methaneν3band with an accurate midinfrared coherent dual-comb spectrometer
Baumann, E., Giorgetta, F. R., Swann, W. C., Zolot, A. M., Coddington, I., & Newbury, N. R. (2011) · Physical Review A · doi:10.1103/physreva.84.062513 · Cited by 252
Continuous real-time correction and averaging for frequency comb interferometry
Roy, J., Deschênes, J.-D., Potvin, S., & Genest, J. (2012) · Optics Express · doi:10.1364/oe.20.021932 · Cited by 245
Yasui, T., Kabetani, Y., Saneyoshi, E., Yokoyama, S., & Araki, T. (2006) · Applied Physics Letters · doi:10.1063/1.2209718 · Cited by 223
Self-citationMultiheterodyne spectroscopy with optical frequency combs generated from a continuous-wave laser
Long, D. A., Fleisher, A. J., Douglass, K. O., Maxwell, S. E., Bielska, K., Hodges, J. T., & Plusquellic, D. F. (2014) · Optics Letters · doi:10.1364/ol.39.002688 · Cited by 174
Ultra-broadband dual-comb spectroscopy across 1.0–1.9 µm
Okubo, S., Iwakuni, K., Inaba, H., Hosaka, K., Onae, A., Sasada, H., & Hong, F.-L. (2015) · Applied Physics Express · doi:10.7567/apex.8.082402 · Cited by 173
Link, S. M., Klenner, A., Mangold, M., Zaugg, C. A., Golling, M., Tilma, B. W., & Keller, U. (2015) · Optics Express · doi:10.1364/oe.23.005521 · Cited by 150
Deschênes, J.-D., Giaccarri, P., & Genest, J. (2010) · Optics Express · doi:10.1364/oe.18.023358 · Cited by 141
Janke, C., Först, M., Nagel, M., Kurz, H., & Bartels, A. (2005) · Optics Letters · doi:10.1364/ol.30.001405 · Cited by 132
Optical sampling by laser cavity tuning
Hochrein, T., Wilk, R., Mei, M., Holzwarth, R., Krumbholz, N., & Koch, M. (2010) · Optics Express · doi:10.1364/oe.18.001613 · Cited by 129
Spectroscopie de Fourier avec transformation d'un million de points
Connes, J., Delouis, H., Connes, P., Guelachvili, G., Maillard, J. P., & Michel, G. (1970) · Nouvelle Revue d Optique Appliquée · doi:10.1088/0029-4780/1/1/301 · Cited by 123
Zhao, X. M., Zheng, Z., Liu, L., Wang, Q., Chen, H., & Liu, J. (2012) · Optics Express · doi:10.1364/oe.20.025584 · Cited by 103
Self-citationAdaptive sampling dual terahertz comb spectroscopy using dual free-running femtosecond lasers
Yasui, T., Ichikawa, R., Hsieh, Y.-D., Hayashi, K., Cahyadi, H., Hindle, F. P., Sakaguchi, Y., Iwata, T., Mizutani, Y., Yamamoto, H., et al. (2015) · Scientific Reports · doi:10.1038/srep10786 · Cited by 74
Self-citationDual-comb self-mode-locked monolithic Yb:KGW laser with orthogonal polarizations
Chang, M. T., Liang, H. C., Su, K. W., & Chen, Y. F. (2015) · Optics Express · doi:10.1364/oe.23.010111 · Cited by 29
Fully referenced single-comb interferometry using optical sampling by laser-cavity tuning
Potvin, S., Boudreau, S., Deschênes, J.-D., & Genest, J. (2013) · Applied Optics · doi:10.1364/ao.52.000248 · Cited by 28
Stable Similariton Generation in an All-Fiber Hybrid Mode-Locked Ring Laser for Frequency Metrology
Lazarev, V. A., Krylov, A. A., Dvoretskiy, D. A., Sazonkin, S. G., Pnev, A. B., Leonov, S. O., Shelestov, D. A., Tarabrin, M. K., Karasik, V. E., Kireev, A. N., et al. (2016) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2016.2542368 · Cited by 24
Cited by
Coddington, I., Newbury, N., & Swann, W. (2016) · Optica · doi:10.1364/optica.3.000414 · Cited by 1,754
“[97] exhibits very-high-quality dual-comb spectra using this approach.”
Picqué, N., & Hänsch, T. W. (2019) · Nature Photonics · doi:10.1038/s41566-018-0347-5 · Cited by 1,255
A phase-stable dual-comb interferometer
Chen, Z., Yan, M., Hänsch, T. W., & Picqué, N. (2018) · Nature Communications · doi:10.1038/s41467-018-05509-6 · Cited by 139
Self-corrected chip-based dual-comb spectrometer
Hébert, N. B., Genest, J., Deschênes, J.-D., Bergeron, H., Chen, G. Y., Khurmi, C., & Lancaster, D. G. (2017) · Optics Express · doi:10.1364/oe.25.008168 · Cited by 122
Dual terahertz comb spectroscopy with a single free-running fibre laser
Hu, G., Mizuguchi, T., Oe, R., Nitta, K., Zhao, X., Minamikawa, T., Li, T., Zheng, Z., & Yasui, T. (2018) · Scientific Reports · doi:10.1038/s41598-018-29403-9 · Cited by 56
Self-citation
Metadata
- Authors
- Zhao, X., Hu, G., Zhao, B., Li, C., Pan, Y., Liu, Y., Yasui, T., & Zheng, Z.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2016-09-12
- Volume
- 24
- Issue
- 19
- Pages
- 21833
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2283235394
- Cited by
- 264
- References
- 34
- FWCI
- 13.18
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.