The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Three-dimensional photoacoustic imaging of blood vessels in tissue
Abstract
We applied photoacoustics as a tissue tomography technique for the detection of blood concentrations, e.g., angiogenesis around tumors. We imaged blood vessels in highly scattering samples, using 532-nm light, to depths of ~1 cm . The samples were real tissue (chicken breast) or 10% dilutions of Intralipid-10%. The blood flowed through nylon capillaries. Polyvinylidene difluoride (PVdF) piezoelectric detectors were used in a surface-scanning mode. We demonstrate the sensitivity of the technique by photoacoustic detection of single red blood cells upon a glass plate. Lateral resolution is limited by the detector diameter (200 microm). The depth resolution is ~10 microm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Applications of photoacoustic sensing techniques
Tam, A. C. (1986) · Reviews of Modern Physics · doi:10.1103/revmodphys.58.381 · Cited by 1,306
Light scattering in lntralipid-10% in the wavelength range of 400–1100 nm
van Staveren, H. J., Moes, C. J. M., van Marie, J., Prahl, S. A., & van Gemert, M. J. C. (1991) · Applied Optics · doi:10.1364/ao.30.004507 · Cited by 1,106
Photoacoustic ultrasound (PAUS)—Reconstruction tomography
Kruger, R. A., Liu, P., Fang, Y. “., & Appledorn, C. R. (1995) · Medical Physics · doi:10.1118/1.597429 · Cited by 572
Oraevsky, A. A., Jacques, S. L., & Tittel, F. K. (1997) · Applied Optics · doi:10.1364/ao.36.000402 · Cited by 298
Optical properties of human dermis in vitro and in vivo
Graaff, R., Dassel, A. C. M., Koelink, M. H., de Mul, F. F. M., Aarnoudse, J. G., & Zijlstra, W. G. (1993) · Applied Optics · doi:10.1364/ao.32.000435 · Cited by 177
Self-citationThe photoacoustic effect generated by an isotropic solid sphere
Khan, M. I., & Diebold, G. J. (1995) · Ultrasonics · doi:10.1016/0041-624x(95)00034-z · Cited by 44
Cited by
Photoacoustic imaging in biomedicine
Xu, M., & Wang, L. V. (2006) · Review of Scientific Instruments · doi:10.1063/1.2195024 · Cited by 2,700
Biomedical photoacoustic imaging
Beard, P. (2011) · Interface Focus · doi:10.1098/rsfs.2011.0028 · Cited by 2,205
Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging
Zhang, H. F., Maslov, K., Stoica, G., & Wang, L. V. (2006) · Nature Biotechnology · doi:10.1038/nbt1220 · Cited by 1,854
Wang, X., Pang, Y., Ku, G., Xie, X., Stoica, G., & Wang, L. V. (2003) · Nature Biotechnology · doi:10.1038/nbt839 · Cited by 1,700
Multiscale photoacoustic microscopy and computed tomography
Wang, L. V. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.157 · Cited by 1,400
Metadata
- Authors
- Hoelen, C. G. A., de Mul, F. F. M., Pongers, R., & Dekker, A.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 1998-04-15
- Volume
- 23
- Issue
- 8
- Pages
- 648
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2141668152
- Cited by
- 446
- References
- 7
- FWCI
- 10.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.