In vivo dark-field reflection-mode photoacoustic microscopy
Open accessAbstract
Reflection-mode photoacoustic microscopy with dark-field laser pulse illumination and high-numerical-aperture ultrasonic detection is designed and implemented in noninvasively imaged blood vessels in the skin in vivo. Dark-field optical illumination minimizes the interference caused by strong photoacoustic signals from superficial structures. A high-numerical-aperture acoustic lens provides high lateral resolution, 45-120 microm in this system. A broadband ultrasonic detection system provides high axial resolution, estimated to be approximately 15 microm. The optical illumination and ultrasonic detection are in a coaxial confocal configuration for optimal image quality. The system is capable of imaging optical-absorption contrast as deep as 3 mm in biological tissue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Angiogenesis in cancer and other diseases
Carmeliet, P., & Jain, R. K. (2000) · Nature · doi:10.1038/35025220 · Cited by 9,070
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Wang, X., Pang, Y., Ku, G., Xie, X., Stoica, G., & Wang, L. V. (2003) · Nature Biotechnology · doi:10.1038/nbt839 · Cited by 1,700
Self-citationOptical properties of intralipid: A phantom medium for light propagation studies
Flock, S. T., Jacques, S. L., Wilson, B. C., Star, W. M., & van Gemert, M. J. C. (1992) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1900120510 · Cited by 578
Three-dimensional photoacoustic imaging of blood vessels in tissue
Hoelen, C. G. A., de Mul, F. F. M., Pongers, R., & Dekker, A. (1998) · Optics Letters · doi:10.1364/ol.23.000648 · Cited by 446
Xu, M., Xu, Y., & Wang, L. V. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.816081 · Cited by 274
Self-citation
Cited by
Photoacoustic imaging in biomedicine
Xu, M., & Wang, L. V. (2006) · Review of Scientific Instruments · doi:10.1063/1.2195024 · Cited by 2,700
Self-citationBiomedical photoacoustic imaging
Beard, P. (2011) · Interface Focus · doi:10.1098/rsfs.2011.0028 · Cited by 2,205
Going deeper than microscopy: the optical imaging frontier in biology
Ntziachristos, V. (2010) · Nature Methods · doi:10.1038/nmeth.1483 · Cited by 1,896
Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging
Zhang, H. F., Maslov, K., Stoica, G., & Wang, L. V. (2006) · Nature Biotechnology · doi:10.1038/nbt1220 · Cited by 1,854
Self-citationA review of clinical photoacoustic imaging: Current and future trends
Attia, A. B. E., Balasundaram, G., Moothanchery, M., Dinish, U. S., Bi, R., Ntziachristos, V., & Olivo, M. (2019) · Photoacoustics · doi:10.1016/j.pacs.2019.100144 · Cited by 878
Metadata
- Authors
- Maslov, K., Stoica, G., & Wang, L. V.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2005-03-15
- Volume
- 30
- Issue
- 6
- Pages
- 625
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2034849654
- Cited by
- 413
- References
- 6
- FWCI
- 13.01
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.