The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Optical properties of intralipid: A phantom medium for light propagation studies
Abstract
Intralipid™ is an intravenous nutrient consisting of an emulsion of phospholipid micelles and water. Because Intralipid is turbid and has no strong absorption bands in the visible region of the electromagnetic spectrum, and is readily available and relatively inexpensive, it is often used as a tissue simulating phantom medium in light dosimetry experiments. In order to assist investigators requiring a controllable medium that over a finite range of wavelengths is optically equivalent to tissue, we have compiled previously published values of the optical interaction coefficients of Intralipid, most of which were measured at a wavelength of 633 nm. We have extended the measurements of the absorption and reduced scattering coefficients from 460 to 690 nm and the total attenuation coefficient from 500 to 890 nm. These measurements show that, for stock 10% Intralipid, the absorption coefficient varies from 0.015 to 0.001 cm−1 between 460 and 690 nm, the reduced scattering coefficient varies from 92 to 50 cm−1 between 460 and 690 nm, the total attenuation coefficient varies from 575 to 150 cm−1 between 500 and 890 nm, and the average cosine of scatter varies from 0.87 to 0.82 between 460 and 690 nm. With these data, we discuss the design of an optically tissue‐equivalent phantom consisting of Intralipid and black India ink. © 1992 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Absorption and Scattering of Light by Small Particles
Bohren, C. F., & Huffman, D. R. (1998) · doi:10.1002/9783527618156 · Cited by 18,474
Absorption and Scattering of Light by Small Particles
Brown, R. G. W. (1984) · Optica Acta: International Journal of Optics · doi:10.1080/716099663 · Cited by 6,612
Optical Constants of Water in the 200-nm to 200-μm Wavelength Region
Hale, G. M., & Querry, M. R. (1973) · Applied Optics · doi:10.1364/ao.12.000555 · Cited by 4,468
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Light scattering in lntralipid-10% in the wavelength range of 400–1100 nm
van Staveren, H. J., Moes, C. J. M., van Marie, J., Prahl, S. A., & van Gemert, M. J. C. (1991) · Applied Optics · doi:10.1364/ao.30.004507 · Cited by 1,106
Self-citationThe multiplier method of Hestenes and Powell applied to convex programming
Rockafellar, R. T. (1973) · Journal of Optimization Theory and Applications · doi:10.1007/bf00934777 · Cited by 705
Photophysical processes in recent medical laser developments: A review
Boulnois, J.-L. (1986) · Lasers in Medical Science · doi:10.1007/bf02030737 · Cited by 661
Multiple Light Scattering: Tables, Formulas, and Applications
van de Hulst, H. C. (1980) · CERN Document Server (European Organization for Nuclear Research) · Cited by 499
Scattering and absorption of turbid materials determined from reflection measurements 1: Theory
Groenhuis, R. A. J., Ferwerda, H. A., & Ten Bosch, J. J. (1983) · Applied Optics · doi:10.1364/ao.22.002456 · Cited by 490
Flock, S. T., Patterson, M. S., Wilson, B. C., & Wyman, D. R. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1989.1173624 · Cited by 489
Self-citation
Cited by
Welsher, K., Sherlock, S. P., & Dai, H. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1014501108 · Cited by 958
Chemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy
Evans, C. L., Potma, E. O., Puoris'haag, M., Côté, D., Lin, C. P., & Xie, X. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0508282102 · Cited by 957
Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry
Pogue, B. W., & Patterson, M. S. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2335429 · Cited by 837
Anti-quenching NIR-II molecular fluorophores for in vivo high-contrast imaging and pH sensing
Wang, S., Fan, Y., Li, D., Sun, C., Lei, Z., Lu, L., Wang, T., & Zhang, F. (2019) · Nature Communications · doi:10.1038/s41467-019-09043-x · Cited by 510
Light Sources and Dosimetry Techniques for Photodynamic Therapy
Kim, M. M., & Darafsheh, A. (2020) · Photochemistry and Photobiology · doi:10.1111/php.13219 · Cited by 454
Metadata
- Authors
- Flock, S. T., Jacques, S. L., Wilson, B. C., Star, W. M., & van Gemert, M. J. C.
- Venue
- Lasers in Surgery and Medicine
- Publisher
- Wiley
- Published
- 1992-01
- Volume
- 12
- Issue
- 5
- Pages
- 510-519
- ISSN
- 0196-8092 (ISSN-L)
- 1096-9101
- OpenAlex
- W2033705563
- Cited by
- 578
- References
- 22
- FWCI
- 2.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical properties of intralipid: A phantom medium for light propagation studies. https://app.cochat.ai/papers/10.1002/lsm.1900120510
- The paper
- Flock, S. T., Jacques, S. L., Wilson, B. C., Star, W. M., & van Gemert, M. J. C. (1992). Optical properties of intralipid: A phantom medium for light propagation studies. Lasers in Surgery and Medicine. https://doi.org/10.1002/lsm.1900120510
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.