Effects of surface roughness on reflection spectra obtained by terahertz time-domain spectroscopy
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
We present an analytical model that shows that reflection from a rough surface causes a Gaussian frequency roll-off for the spectral magnitude of a terahertz wave and reduces the signal-to-noise ratio of terahertz time-domain spectroscopy. The parameter that determines the width of the frequency roll-off is the standard deviation of the surface height distribution. Measurements of terahertz waves reflected from copper powder samples provide experimental evidence for this effect.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Far-infrared time-domain spectroscopy with terahertz beams of dielectrics and semiconductors
Grischkowsky, D., Keiding, S., van Exter, M., & Fattinger, C. (1990) · Journal of the Optical Society of America B · doi:10.1364/josab.7.002006 · Cited by 2,239
Dynamic range in terahertz time-domain transmission and reflection spectroscopy
Jepsen, P. U., & Fischer, B. M. (2005) · Optics Letters · doi:10.1364/ol.30.000029 · Cited by 382
Convertible transmission-reflection time-domain terahertz spectrometer
Khazan, M., Meissner, R., & Wilke, I. (2001) · Review of Scientific Instruments · doi:10.1063/1.1384433 · Cited by 54
Cited by
THz Medical Imaging: in vivo Hydration Sensing
Taylor, Z. D., Singh, R. S., Bennett, D. B., Tewari, P., Kealey, C. P., Bajwa, N., Culjat, M. O., Stojadinovic, A., Lee, H., Hubschman, J.-P., et al. (2011) · IEEE Transactions on Terahertz Science and Technology · doi:10.1109/tthz.2011.2159551 · Cited by 362
Characterisation of pore structures of pharmaceutical tablets: A review
Markl, D., Strobel, A., Schlossnikl, R., Bøtker, J., Bawuah, P., Ridgway, C., Rantanen, J., Rades, T., Gane, P., Peiponen, K.-E., et al. (2018) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2018.01.017 · Cited by 154
“The amplitude of the reflected terahertz pulse of a solid sample is correlated to the 775 surface roughness (Dikmelik et al., 2006; Jagannathan et al., 2009; Mou et al., 2017), which has been 776 demonstrated for different pharmaceutical materials (Chakraborty et al., 2016; Markl et al., 2017b).”
BackgroundKhani, M. E., Winebrenner, D. P., & Arbab, M. H. (2020) · IEEE Transactions on Terahertz Science and Technology · doi:10.1109/tthz.2020.2997595 · Cited by 31
Khani, M. E., & Arbab, M. H. (2021) · IEEE Access · doi:10.1109/access.2021.3059424 · Cited by 29
“However, in the reflection-mode THz spectroscopy, surface height variations on the order of the illumination wavelengths result in significant rough surface scattering, which can distort or obscure the resonant signatures [8]–[10].”
BackgroundSpectral artifacts from non-uniform samples analyzed by terahertz time-domain spectroscopy
Théberge, F., Châteauneuf, M., Dubois, J., Désilets, S., & Lussier, L.-S. (2009) · Optics Express · doi:10.1364/oe.17.010841 · Cited by 14
Metadata
- Authors
- Dikmelik, Y., Spicer, J. B., Fitch, M. J., & Osiander, R.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2006-11-22
- Volume
- 31
- Issue
- 24
- Pages
- 3653
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W1981609198
- Cited by
- 49
- References
- 3
- FWCI
- 4.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.