Second-generation optical-resolution photoacoustic microscopy with improved sensitivity and speed
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
We developed second-generation (G2) optical-resolution photoacoustic microscopy (OR-PAM). Incorporation of a novel acoustic detection scheme improved upon the sensitivity of our first-generation (G1) system by 18.4 dB, deepening the in vivo tissue penetration to 1.2 mm at 570 nm. Moreover, translating the imaging head instead of the living object accelerated the scanning speed by a factor of 5, widening the field of view within the same acquisition time. Mouse ears, as well as mouse brains with intact craniums, were imaged in vivo in both total concentration and oxygen saturation of hemoglobin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kinsler, L. E., Frey, A. R., & Bennett, G. S. (1951) · American Journal of Physics · doi:10.1119/1.1932798 · Cited by 3,375
Brekhovskikh, L. M., Lieberman, D. A., Beyer, R. T., Frenkiel, F. N., & Chako, N. (1960) · Cited by 2,785
Optical-resolution photoacoustic microscopy for in vivo imaging of single capillaries
Maslov, K., Zhang, H. F., Hu, S., & Wang, L. V. (2008) · Optics Letters · doi:10.1364/ol.33.000929 · Cited by 763
Self-citationPhotoacoustic ophthalmoscopy for in vivo retinal imaging
Jiao, S., Jiang, M., Hu, J., Fawzi, A., Zhou, Q., Shung, K. K., Puliafito, C. A., & Zhang, H. F. (2010) · Optics Express · doi:10.1364/oe.18.003967 · Cited by 258
Label-free photoacoustic ophthalmic angiography
Hu, S., Rao, B., Maslov, K., & Wang, L. V. (2009) · Optics Letters · doi:10.1364/ol.35.000001 · Cited by 148
Self-citationNoninvasive label-free imaging of microhemodynamics by optical-resolution photoacoustic microscopy
Hu, S., Maslov, K., & Wang, L. V. (2009) · Optics Express · doi:10.1364/oe.17.007688 · Cited by 117
Self-citationHu, S., Yan, P., Maslov, K., Lee, J., & Wang, L. V. (2009) · Optics Letters · doi:10.1364/ol.34.003899 · Cited by 104
Self-citationOladipupo, S. S., Hu, S., Santeford, A. C., Yao, J., Kovalski, J. R., Shohet, R. V., Maslov, K., Wang, L. V., & Arbeit, J. M. (2011) · Blood · doi:10.1182/blood-2010-09-307538 · Cited by 87
Self-citation
Cited by
Photoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331
Self-citationBiomedical photoacoustic imaging
Beard, P. (2011) · Interface Focus · doi:10.1098/rsfs.2011.0028 · Cited by 2,205
A review of clinical photoacoustic imaging: Current and future trends
Attia, A. B. E., Balasundaram, G., Moothanchery, M., Dinish, U. S., Bi, R., Ntziachristos, V., & Olivo, M. (2019) · Photoacoustics · doi:10.1016/j.pacs.2019.100144 · Cited by 878
Photoacoustic Imaging: Contrast Agents and Their Biomedical Applications
Fu, Q., Zhu, R., Song, J., Yang, H., & Chen, X. (2019) · Advanced Materials · doi:10.1002/adma.201805875 · Cited by 681
PHOTOACOUSTIC TOMOGRAPHY: PRINCIPLES AND ADVANCES (Invited Review)
Xia, J., Yao, J., & Wang, L. H. V. (2014) · Progress In Electromagnetics Research · doi:10.2528/pier14032303 · Cited by 646
Self-citationYao, J., & Wang, L. V. (2013) · Laser & Photonics Reviews · doi:10.1002/lpor.201200060 · Cited by 616
Self-citationOptical coherence tomography today: speed, contrast, and multimodality
Drexler, W., Liu, M., Kumar, A., Kamali, T., Unterhuber, A., & Leitgeb, R. A. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.7.071412 · Cited by 473
Li, J., Rao, J., & Pu, K. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2017.11.025 · Cited by 469
Tutorial on photoacoustic tomography
Zhou, Y., Yao, J., & Wang, L. V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.6.061007 · Cited by 421
Self-citationSensitivity of photoacoustic microscopy
Yao, J., & Wang, L. V. (2014) · Photoacoustics · doi:10.1016/j.pacs.2014.04.002 · Cited by 418
Self-citationUltrasensitive plano-concave optical microresonators for ultrasound sensing
Guggenheim, J. A., Li, J., Allen, T. J., Colchester, R. J., Noimark, S., Ogunlade, O., Parkin, I. P., Papakonstantinou, I., Desjardins, A. E., Zhang, E. Z., et al. (2017) · Nature Photonics · doi:10.1038/s41566-017-0027-x · Cited by 391
Structural and functional photoacoustic molecular tomography aided by emerging contrast agents
Nie, L., & Chen, X. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00086b · Cited by 383
Advanced optoacoustic methods for multiscale imaging of in vivo dynamics
Deán-Ben, X. L., Gottschalk, S., Mc Larney, B., Shoham, S., & Razansky, D. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00765a · Cited by 337
Recent Advances in Photoacoustic Imaging for Deep-Tissue Biomedical Applications
Wang, S., Lin, J., Wang, T., Chen, X., & Huang, P. (2016) · Theranostics · doi:10.7150/thno.16715 · Cited by 261
Noninvasive photoacoustic computed tomography of mouse brain metabolism in vivo
Yao, J., Xia, J., Maslov, K. I., Nasiriavanaki, M., Tsytsarev, V., Demchenko, A. V., & Wang, L. V. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.08.054 · Cited by 235
Self-citationReview of deep learning for photoacoustic imaging
Yang, C., Lan, H., Gao, F., & Gao, F. (2021) · Photoacoustics · doi:10.1016/j.pacs.2020.100215 · Cited by 185
Strategies for Image-Guided Therapy, Surgery, and Drug Delivery Using Photoacoustic Imaging
Moore, C., & Jokerst, J. V. (2019) · Theranostics · doi:10.7150/thno.32362 · Cited by 169
Metadata
- Authors
- Hu, S., Maslov, K., & Wang, L. V.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2011-03-23
- Volume
- 36
- Issue
- 7
- Pages
- 1134
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W1982367678
- Cited by
- 429
- References
- 8
- FWCI
- 17.87
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.