A Comparison of Donor-Acceptor Pairs for Genetically Encoded FRET Sensors: Application to the Epac cAMP Sensor as an Example
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
We recently reported on CFP-Epac-YFP, an Epac-based single polypeptide FRET reporter to resolve cAMP levels in living cells. In this study, we compared and optimized the fluorescent protein donor/acceptor pairs for use in biosensors such as CFP-Epac-YFP. Our strategy was to prepare a wide range of constructs consisting of different donor and acceptor fluorescent proteins separated by a short linker. Constructs were expressed in HEK293 cells and tested for FRET and other relevant properties. The most promising pairs were subsequently used in an attempt to improve the FRET span of the Epac-based cAMP sensor. The results show significant albeit not perfect correlation between performance in the spacer construct and in the Epac sensor. Finally, this strategy enabled us to identify improved sensors both for detection by sensitized emission and by fluorescent lifetime imaging. The present overview should be helpful in guiding development of future FRET sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zwischenmolekulare Energiewanderung und Fluoreszenz
Förster, T. (1948) · Annalen der Physik · doi:10.1002/andp.19484370105 · Cited by 8,285
Shaner, N. C., Campbell, R. E., Steinbach, P. A., Giepmans, B. N. G., Palmer, A. E., & Tsien, R. Y. (2004) · Nature Biotechnology · doi:10.1038/nbt1037 · Cited by 4,619 · cited 16×
“Slow green-to-red maturation terminated some of the otherwise most promising FRET pairs, e.g. those with tdTomato as acceptor.”
BackgroundMethodInfluentialFluorescent indicators for Ca2+based on green fluorescent proteins and calmodulin
Miyawaki, A., Llopis, J., Heim, R., McCaffery, J. M., Adams, J. A., Ikura, M., & Tsien, R. Y. (1997) · Nature · doi:10.1038/42264 · Cited by 3,248 · cited 3×
“The original EPAC sensor contains CFP and YFP [15].”
BackgroundNagai, T., Ibata, K., Park, E. S., Kubota, M., Mikoshiba, K., & Miyawaki, A. (2002) · Nature Biotechnology · doi:10.1038/nbt0102-87 · Cited by 2,753 · cited 2×
“Venus and cpVenus FPs were generated by PCR using the following templates: Venus [21] and cpVenus (from Ycam 3.”
MethodA monomeric red fluorescent protein
Campbell, R. E., Tour, O., Palmer, A. E., Steinbach, P. A., Baird, G. S., Zacharias, D. A., & Tsien, R. Y. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.082243699 · Cited by 2,365 · cited 3×
“Therefore we tested some of the newer red FPs, notably mRFP1 [28], mCherry, mOrange [8] and HcRed [34].”
MethodPartitioning of Lipid-Modified Monomeric GFPs into Membrane Microdomains of Live Cells
Zacharias, D. A., Violin, J. D., Newton, A. C., & Tsien, R. Y. (2002) · Science · doi:10.1126/science.1068539 · Cited by 2,235 · cited 1×
“GFP-derivatives such as CFP and YFP have an inherent tendency to form dimers at high concentrations”
BackgroundFluorescent proteins from nonbioluminescent Anthozoa species
Matz, M. V., Fradkov, A. F., Labas, Y. A., Savitsky, A. P., Zaraisky, A. G., Markelov, M. L., & Lukyanov, S. A. (1999) · Nature Biotechnology · doi:10.1038/13657 · Cited by 1,838 · cited 1×
“Efficient FRET from CFP to the Discosoma RFP (DsRed) [30] has been demonstrated before [31] [32] [33].”
MethodJares-Erijman, E. A., & Jovin, T. M. (2003) · Nature Biotechnology · doi:10.1038/nbt896 · Cited by 1,824 · cited 1×
“FRET changes may be detected by several microscopical techniques [4], the most important of which are sensitized emission (SE) and fluorescence lifetime imaging (FLIM).”
BackgroundOn/off blinking and switching behaviour of single molecules of green fluorescent protein
Dickson, R. M., Cubitt, A. B., Tsien, R. Y., & Moerner, W. E. (1997) · Nature · doi:10.1038/41048 · Cited by 1,342 · cited 1×
“bleach rate and photochromism [6]), insensitivity to microenviromental conditions such as pH or ionic strength [7] and, in case of uncaging experiments, insensitivity to UV light.”
BackgroundAn improved cyan fluorescent protein variant useful for FRET
Rizzo, M. A., Springer, G. H., Granada, B., & Piston, D. W. (2004) · Nature Biotechnology · doi:10.1038/nbt945 · Cited by 1,077 · cited 2×
“Conversely, SE is insensitive to multi-exponential decay of the fluorescent donor whereas FLIM analysis is severely hampered when more than one decay constant is present [14].”
Background
Cited by
Fluorescent Proteins and Their Applications in Imaging Living Cells and Tissues
Chudakov, D. M., Matz, M. V., Lukyanov, S., & Lukyanov, K. A. (2010) · Physiological Reviews · doi:10.1152/physrev.00038.2009 · Cited by 1,375
Improving FRET dynamic range with bright green and red fluorescent proteins
Lam, A. J., St-Pierre, F., Gong, Y., Marshall, J. D., Cranfill, P. J., Baird, M. A., McKeown, M. R., Wiedenmann, J., Davidson, M. W., Schnitzer, M. J., et al. (2012) · Nature Methods · doi:10.1038/nmeth.2171 · Cited by 732
Greenwald, E. C., Mehta, S., & Zhang, J. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00333 · Cited by 495
Raffaello, A., De Stefani, D., Sabbadin, D., Teardo, E., Merli, G., Picard, A., Checchetto, V., Moro, S., Szabò, I., & Rizzuto, R. (2013) · The EMBO Journal · doi:10.1038/emboj.2013.157 · Cited by 490
Klarenbeek, J., Goedhart, J., van Batenburg, A., Groenewald, D., & Jalink, K. (2015) · PLOS ONE · doi:10.1371/journal.pone.0122513 · Cited by 311
Self-citationSingle Cell Optical Imaging and Spectroscopy
Stender, A. S., Marchuk, K., Liu, C., Sander, S., Meyer, M. W., Smith, E. A., Neupane, B., Wang, G., Li, J., Cheng, J.-X., et al. (2013) · Chemical Reviews · doi:10.1021/cr300336e · Cited by 292
A Versatile Toolkit to Produce Sensitive FRET Biosensors to Visualize Signaling in Time and Space
Fritz, R. D., Letzelter, M., Reimann, A., Martin, K., Fusco, L., Ritsma, L., Ponsioen, B., Fluri, E., Schulte-Merker, S., van Rheenen, J., et al. (2013) · Science Signaling · doi:10.1126/scisignal.2004135 · Cited by 228
Self-citationIntracellular cAMP Sensor EPAC: Physiology, Pathophysiology, and Therapeutics Development
Robichaux, W. G., & Cheng, X. (2018) · Physiological Reviews · doi:10.1152/physrev.00025.2017 · Cited by 208
A mTurquoise-Based cAMP Sensor for Both FLIM and Ratiometric Read-Out Has Improved Dynamic Range
Klarenbeek, J. B., Goedhart, J., Hink, M. A., Gadella, T. W. J., & Jalink, K. (2011) · PLoS ONE · doi:10.1371/journal.pone.0019170 · Cited by 208
Self-citationGenetic dissection of GABAergic neural circuits in mouse neocortex
Taniguchi, H. (2014) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2014.00008 · Cited by 106
“Voltagedependent conformational changes in the voltage-sensing domain lead to either changes in the intensity of the fluorescent protein or changes in Forster resonant energy transfer (FRET) between fluorescent proteins.”
BackgroundMethodInfluential
Metadata
- Authors
- van der Krogt, G. N. M., Ogink, J., Ponsioen, B., & Jalink, K.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2008-04-02
- Volume
- 3
- Issue
- 4
- Pages
- e1916
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2079245879
- Cited by
- 174
- References
- 38
- FWCI
- 6.06
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.