Intra-Platform Repeatability and Inter-Platform Comparability of MicroRNA Microarray Technology
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Over the last decade, DNA microarray technology has provided a great contribution to the life sciences. The MicroArray Quality Control (MAQC) project demonstrated the way to analyze the expression microarray. Recently, microarray technology has been utilized to analyze a comprehensive microRNA expression profiling. Currently, several platforms of microRNA microarray chips are commercially available. Thus, we compared repeatability and comparability of five different microRNA microarray platforms (Agilent, Ambion, Exiqon, Invitrogen and Toray) using 309 microRNAs probes, and the Taqman microRNA system using 142 microRNA probes. This study demonstrated that microRNA microarray has high intra-platform repeatability and comparability to quantitative RT-PCR of microRNA. Among the five platforms, Agilent and Toray array showed relatively better performances than the others. However, the current lineup of commercially available microRNA microarray systems fails to show good inter-platform concordance, probably because of lack of an adequate normalization method and severe divergence in stringency of detection call criteria between different platforms. This study provided the basic information about the performance and the problems specific to the current microRNA microarray systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative Monitoring of Gene Expression Patterns with a Complementary DNA Microarray
Schena, M., Shalon, D., Davis, R. W., & Brown, P. O. (1995) · Science · doi:10.1126/science.270.5235.467 · Cited by 9,609
Identification of Novel Genes Coding for Small Expressed RNAs
Lagos-Quintana, M., Rauhut, R., Lendeckel, W., & Tuschl, T. (2001) · Science · doi:10.1126/science.1064921 · Cited by 4,956 · cited 1×
“It is reported that microRNAs are involved in physiological and pathological functions, such as the regulation of developmental timing and pattern formation [12], restriction of differentiation potential [13], chromatin rearrangements [14], and carcinogenesis [15].”
BackgroundJohn, B., Enright, A. J., Aravin, A., Tuschl, T., Sander, C., & Marks, D. S. (2004) · PLoS Biology · doi:10.1371/journal.pbio.0020363 · Cited by 3,796 · cited 1×
“It is reported that microRNAs are involved in physiological and pathological functions, such as the regulation of developmental timing and pattern formation [12], restriction of differentiation potential [13], chromatin rearrangements [14], and carcinogenesis [15].”
BackgroundA Mammalian microRNA Expression Atlas Based on Small RNA Library Sequencing
Landgraf, P., Rusu, M., Sheridan, R., Sewer, A., Iovino, N., Aravin, A., Pfeffer, S., Rice, A., Kamphorst, A. O., Landthaler, M., et al. (2007) · Cell · doi:10.1016/j.cell.2007.04.040 · Cited by 3,626 · cited 1×
“The next-generation sequencing technology has been applied to microRNA detection [21].”
MethodMAQC Consortium, Shi, L., Shi, L., Reid, L. H., Jones, W. D., Shippy, R., Warrington, J. A., Baker, S. C., Collins, P. J., de Longueville, F., et al. (2006) · Nature Biotechnology · doi:10.1038/nbt1239 · Cited by 2,126 · cited 2×
“In the MAQC project, seven different platforms (Applied Biosystems, Affymetrix, Agilent, Eppendolf, GE Healthcare, Illumina, and NCI array) were compared [6].”
MethodUsing RNA sample titrations to assess microarray platform performance and normalization techniques
Shippy, R., Fulmer-Smentek, S., Jensen, R. V., Jones, W. D., Wolber, P. K., Johnson, C. D., Pine, P. S., Boysen, C., Guo, X., Chudin, E., et al. (2006) · Nature Biotechnology · doi:10.1038/nbt1241 · Cited by 173 · cited 1×
“project was published in 2006 [2–7].”
Cited by
miRNAs as Biomarkers in Disease: Latest Findings Regarding Their Role in Diagnosis and Prognosis
Condrat, C. E., Thompson, D. C., Barbu, M. G., Bugnar, O. L., Boboc, A., Cretoiu, D., Suciu, N., Cretoiu, S. M., & Voinea, S. C. (2020) · Cells · doi:10.3390/cells9020276 · Cited by 1,344
MicroRNA: Function, Detection, and Bioanalysis
Dong, H., Lei, J., Ding, L., Wen, Y., Ju, H., & Zhang, X. (2013) · Chemical Reviews · doi:10.1021/cr300362f · Cited by 1,224
MicroRNA as Biomarkers and Diagnostics
Wang, J., Chen, J., & Sen, S. (2016) · Journal of Cellular Physiology · doi:10.1002/jcp.25056 · Cited by 793
“Data reproducibility is also a problem, and the results obtained by the same profiling method are not always consistent (Sato et al., 2009).”
BackgroundGit, A., Dvinge, H., Salmon-Divon, M., Osborne, M., Kutter, C., Hadfield, J., Bertone, P., & Caldas, C. (2010) · RNA · doi:10.1261/rna.1947110 · Cited by 689
Extracellular microRNA: A new source of biomarkers
Etheridge, A., Lee, I., Hood, L., Galas, D., & Wang, K. (2011) · Mutation Research - Fundamental and Molecular Mechanisms of Mutagenesis · doi:10.1016/j.mrfmmm.2011.03.004 · Cited by 659
Comparing the MicroRNA Spectrum between Serum and Plasma
Wang, K., Yuan, Y., Cho, J.-H., McClarty, S., Baxter, D., & Galas, D. J. (2012) · PLoS ONE · doi:10.1371/journal.pone.0041561 · Cited by 654
Sato, F., Tsuchiya, S., Meltzer, S. J., & Shimizu, K. (2011) · The FEBS Journal · doi:10.1111/j.1742-4658.2011.08089.x · Cited by 588
Self-citationOhshima, K., Inoue, K., Fujiwara, A., Hatakeyama, K., Kanto, K., Watanabe, Y., Muramatsu, K., Fukuda, Y., Ogura, S.-I., Yamaguchi, K., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0013247 · Cited by 577
Data Normalization Strategies for MicroRNA Quantification
Schwarzenbach, H., da Silva, A. M., Calin, G., & Pantel, K. (2015) · Clinical Chemistry · doi:10.1373/clinchem.2015.239459 · Cited by 468
Methodological challenges in utilizing mi RNA s as circulating biomarkers
Moldovan, L., Batte, K. E., Trgovcich, J., Wisler, J., Marsh, C. B., & Piper, M. (2014) · Journal of Cellular and Molecular Medicine · doi:10.1111/jcmm.12236 · Cited by 436
“Various studies have been designed to understand the reproducibility, sensitivity and specificity of various platforms for mRNA [156] or miRNA [157].”
BackgroundRNA-Based Therapeutics: From Antisense Oligonucleotides to miRNAs
Bajan, S., & Hutvagner, G. (2020) · Cells · doi:10.3390/cells9010137 · Cited by 393
Integrated extracellular microRNA profiling for ovarian cancer screening
Yokoi, A., Matsuzaki, J., Yamamoto, Y., Yoneoka, Y., Takahashi, K., Shimizu, H., Uehara, T., Ishikawa, M., Ikeda, S.-I., Sonoda, T., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-06434-4 · Cited by 315
Complexity of the microRNA repertoire revealed by next-generation sequencing
Lee, L. W., Zhang, S., Etheridge, A., Ma, L., Martin, D., Galas, D., & Wang, K. (2010) · RNA · doi:10.1261/rna.2225110 · Cited by 279
Analytical aspects of microRNA in diagnostics: A review
de Planell-Saguer, M., & Rodicio, M. C. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.05.025 · Cited by 261
Ogawa, T., Enomoto, M., Fujii, H., Sekiya, Y., Yoshizato, K., Ikeda, K., & Kawada, N. (2012) · Gut · doi:10.1136/gutjnl-2011-300717 · Cited by 253
Regulation of cellular miRNA expression by human papillomaviruses
Zheng, Z.-M., & Wang, X. (2011) · Biochimica et Biophysica Acta (BBA) - Gene Regulatory Mechanisms · doi:10.1016/j.bbagrm.2011.05.005 · Cited by 224
Meyer, S. U., Pfaffl, M. W., & Ulbrich, S. E. (2010) · Biotechnology Letters · doi:10.1007/s10529-010-0380-z · Cited by 213
“Normalized miRNA RT-qPCR profiling data is widely used for independent evaluation of the goodness of miRNA microarray normalization strategies (Sarkar et al. 2009; Pradervand et al. 2009; Sato et al. 2009; Hua et al. 2008) and validation of microarray or small RNA-seq results (Git et al. 2010).”
BackgroundMethodMicroRNAs as biomarkers for early breast cancer diagnosis, prognosis and therapy prediction
Nassar, F. J., Nasr, R., & Talhouk, R. (2017) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2016.11.012 · Cited by 208
Potential pitfalls in microRNA profiling
Chugh, P., & Dittmer, D. P. (2012) · WIREs RNA · doi:10.1002/wrna.1120 · Cited by 191
MicroRNA Detection: Current Technology and Research Strategies
Hunt, E. A., Broyles, D., Head, T., & Deo, S. K. (2015) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071114-040343 · Cited by 190
Bustin, S., & Nolan, T. (2017) · European Journal of Clinical Investigation · doi:10.1111/eci.12801 · Cited by 113
Kok, M. G. M., de Ronde, M. W. J., Moerland, P. D., Ruijter, J. M., Creemers, E. E., & Pinto-Sietsma, S. J. (2018) · Biomolecular Detection and Quantification · doi:10.1016/j.bdq.2017.11.002 · Cited by 105
MicroRNA in Alzheimer’s disease: an exploratory study in brain, cerebrospinal fluid and plasma
Bekris, L. M., Lutz, F., Montine, T. J., Yu, C. E., Tsuang, D., Peskind, E. R., & Leverenz, J. B. (2013) · Biomarkers · doi:10.3109/1354750x.2013.814073 · Cited by 97
Methods and novel technology for microRNA quantification in colorectal cancer screening
Moody, L., He, H., Pan, Y.-X., & Chen, H. (2017) · Clinical Epigenetics · doi:10.1186/s13148-017-0420-9 · Cited by 42
Circulating microRNAs as Promising Tumor Biomarkers
(2014) · Advances in Clinical Chemistry · doi:10.1016/bs.acc.2014.09.007 · Cited by 40
Metadata
- Authors
- Sato, F., Tsuchiya, S., Terasawa, K., & Tsujimoto, G.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2009-05-14
- Volume
- 4
- Issue
- 5
- Pages
- e5540
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2061723075
- Cited by
- 216
- References
- 6
- FWCI
- 5.83
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.